63
14. Appendix
14.3 Administrator Login Failure
If you are unable to perform an Administrator login (e.g. because the username/password information has become
corrupted or you have forgotten it), you can clear the login information with the following procedure:
1
Power off the KVM and remove its housing.
2
Short the jumper labeled DEFAULT PASSWORD.
3
Power on the switch.
4
When the front panel LEDs flash, power off the switch.
5
Remove the jumper cap.
6
Close the housing and restart the KVM. After restarting, you can use the default login procedure to login
(see
9.1 OSD Login
).
14.4 Factory Default Hotkeys and Settings
Setting
Default
OSD Hotkey
[Scroll Lock] [Scroll Lock]
Invoking HSM Hotkey
[Number Lock] [-]
Port ID Display Position
Upper Left Corner
Port ID Display Duration
3 Seconds
Port ID Display Mode
The Port Number plus the Port Name
Auto Scan Interval
5 Seconds
Scan/Skip Mode
All Ports
Mouse Emulation
Enabled
Screen Blanker
Disabled
Logout Timeout
Disabled
EDID Mode
HDMI Monitor’s EDID
Beeper
Enabled
Accessible Ports
Full for All Users on All Ports
Video DynaSync
Enabled