I n s t a l l a t i o n ,   O p e r a t i o n ,   a n d   S e r v i c e   M a n u a l

14

8.   Spare Parts

Recommended spare part quantities are usually 

based on the unit size and the amount of units per 

installation.  For  specific  recommendations,  consult 

the TRION

®

 factory or nearest representative.

Consideration, however, should be given to stocking 

the following components:

DESCRIPTION  

 

QTY.

Power Supply   

 

2

Cell Insulators  

 

6

LED 

 

   2

Brass Contact Plunger  

2

Part numbers are not listed, as they are subject to 

change. Please supply unit model number, unit part 

number, and serial numbers when ordering parts. 

Unit data and system labels located on precipitator 

cabinet. Control data label located inside access door 

of control panel.

LIMITED WARRANTY

Unless otherwise expressly stated in Seller’s published 

specifications  for  the  Goods,  Seller  warrants  that 

that Goods are free from defects in material and 

workmanship, except for services which are warranted 

to be performed in a competent and diligent manner 

in accordance with any mutually agreed specifications. 

The foregoing warranty shall apply for twelve (12) 

months from the date of shipment from Seller’s facility, 

except for services for which the warranty shall apply 

for ninety (90) days from the date of performance (the 

“Warranty Period”). Provided Buyer informs Seller in 

writing of any breach of warranty prior to the expiration 

of the applicable Warranty Period, Seller shall, as its 

sole obligation and Buyer’s sole and exclusive remedy 

for any breach of this warranty, repair or replace/

reperform the Goods which gave rise to the breach or, 

at Seller’ option, refund the amounts paid by Buyer for 

the Goods which gave rise to the breach. Any repair, 

replacement or reperformance by Seller hereunder 

shall not extend the applicable Warranty Period. The 

parties  shall  mutually  agree  on  the  specifications  of 

any test to determine the presence of a defect. Unless 

otherwise agreed upon by Seller in writing, Buyer shall 

bear the costs of access, de-installation, re-installation 

and transportation of Goods to Seller and back to 

Buyer. These warranties and remedies are conditioned 

upon (a) the proper storage, installation, operation, 

and maintenance of the Goods and conformance with 

the proper operation instruction manuals provided by 

Seller or its suppliers or subcontractors, (b) Buyer 

keeping proper records of operation and maintenance 

during the applicable Warranty Period and providing 

Seller  access  to  those  records,  and  (c)  modification 

or repair of the Goods only as authorized by Seller. 

Seller does not warrant the Goods or any repaired or 

replacement parts against normal wear and tear or 

damage caused by misuse, accident, or use against 

the instructions of Seller. Any modification or repair of 

any of the Goods not authorized by Seller shall render 

the warranty null and void. EXCEPT AS EXPRESSLY 

SET FORTH HEREIN, SELLER MAKES NO OTHER 

WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, 

BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES 

OF MERCHANTABILITY, NON-INFRINGEMENT OR 

FITNESS FOR A PARTICULAR PURPOSE WHICH 

ARE HEREBY DISCLAIMED TO THE EXTENT 

PERMITTED BY APPLICABLE LAW.

Содержание Grease Viper Series

Страница 1: ...T R I O N w w w t r i o n i a q c o m Grease Viper Series Electrostatic Precipitators Commercial Industrial Applications READ AND SAVE THESE INSTRUCTIONS ...

Страница 2: ...or 1 Unpack and Inspect 4 2 Position Air Cleaner Cabinet 5 3 Connect Adjoining Ductwork 5 4 MountDetergentSystem 5 5 Connect Drain 5 6 Connect Water Wash Supply 5 7 MountControlPanel 6 8 Complete Wiring a Primary Wiring 6 b Grounding 6 9 Checkout for System Start up 6 Section 3 Operation Service For the Maintenance Engineer 1 Introduction and Principle of Operation 6 2 General Description 7 3 Init...

Страница 3: ...reactivated carbon Gasketed access doors located on one side of the cabinet 90 degrees to the direction of the airflow provide entry for removal of the cells and filters The location of the access doors may be specified as right hand or left hand access determined by facing the inlet of the ESP dirty airflow at your back The solid state high voltage power supplies are factory installed and wired w...

Страница 4: ...nit and detergent system Where applicable all water lines must be protected from freezing SAFETY NOTE Factory designed access to all electrically charged high voltage components contain electrical interlocks for the safety of operating personnel Any additional access that may be provided in the system where there is access to high voltage must be equipped with such interlocks Interlocks are readil...

Страница 5: ... pan supply through the floor The recommended drain line trap to seal off the cabinet from the drain against the system pressure and the drain dump valve should be located in the heated interior If not installed in this manner heat trace or other means should be employed to prevent freezing Clean outs are recommended to be installed in all drain lines Wash Water Supply Line The length of the wash ...

Страница 6: ...emperatures must be considered see detailed Warning on Page 6 cabinet then re install the ionizing collecting cells and all other filters When the ionizing collecting cells are reinstalled the directional arrows on the cell end plates must concur with airflow direction through the cabinet Impinger prefilters are to be installed within the inlet plenum section on the air entering side of the unit 4...

Страница 7: ...n accordance with the plumbing schematic to prevent freezing 2 All piping exposed to cold climate outdoor conditions should be heat traced and insulated to prevent freezing 3 An air gap fitting should be installed on the drain line to facilitate gravity draining of wash water from the internal headers and manifolds 4 The water supply line should be pitched back toward the heated space 9 Check Out ...

Страница 8: ...s On multi cell units all of the electrical connections between cells in a given tier are automatically made through spring plunger connectors Install cells into the cabinet in accordance with the directional arrows on the cell end plates The side of the cell containing the spiked ionizer blades must always be located on the air entering side The spring plunger connectors located on one end of eac...

Страница 9: ...in the drain basin for any restrictions The ducting where secured to the cabinet collars should be sealed water tight either with gasketing or caulking 2 Inspect the ionizing collecting cells to see that all of the ionizing blades are intact that no large pieces of foreign material are lodged between the plates and that the cells are properly installed in the cabinet with the spiked ionizing blade...

Страница 10: ...ion is only effective when timer is running in AUTO mode Temporary Override Condition 1 When timer s output status is ON press MANUAL key to move indicator from AUTO to OFF Timer output shall turn to OFF status programs overrided Press MANUAL again to switch timer status to AUTO Timer s output shall continue maintaining OFF Timer shall resume its automatic operation when next program event calls f...

Страница 11: ...he inside of the tank should be kept clean free from dirt and foreign objects The detergent as supplied by TRION is formulated specifically for electronic air cleaners If substitutes are used they must be approved by TRION so as to not void the warranty They should be safe for use in ventilation systems and non caustic as 95 of the ionizing collecting cells are constructed of aluminum special high...

Страница 12: ... or cleaning shall be maintained on the premises WARNING RISK OF ELECTRIC SHOCK These servicing instructions are for use by qualified personnel only To reduce the risk of electric shock do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so NOTE All repairs to the fire suppression system if supplied must be completed by the authorized...

Страница 13: ...h voltage power supply s is 12 000 VDC and up to 8 MA When the power supply s is de energized there is a 20 second delay for the voltage to decay Always short from ground to a point of high voltage with a well insulated jumper wire or an insulated handled screwdriver to bleed off any remaining residual charge NOTE It will be necessary to close the access door electrical interlock switch operated b...

Страница 14: ... indicating light Replace light d Malfunctions other than short or open circuits refer to the Troubleshooting Reference Chart below Problem Symptom Probable Cause Location Reason Correction Indicating Light Not Glowing Short Circuit Ionizing Section of Cell 1 Dirty Insulator s Clean 2 Defective Insulator s Replace 3 Foreign Object between Spiked Ionizer and Ground Electrode Remove Collecting Secti...

Страница 15: ...on and Buyer s sole and exclusive remedy for any breach of this warranty repair or replace reperform the Goods which gave rise to the breach or at Seller option refund the amounts paid by Buyer for the Goods which gave rise to the breach Any repair replacement or reperformance by Seller hereunder shall not extend the applicable Warranty Period The parties shall mutually agree on the specifications...

Страница 16: ...TRION 101 McNeill Rd Sanford NC 27330 P 800 884 0002 F 800 458 2379 www trioniaq com customerservice trioniaq com TRION 2017 All Rights Reserved Form No 266206 001 Rev 09 17 ...