Troubleshooting Reference Chart
PROBLEM/
SYMPTOM
PROBABLE
CAUSE
LOCATION
REASON - CORRECTION
Ionizing Section of Cell
1. Dirty insulator(s) – Clean
2. Defective insulator(s) – Replace
3. Foreign Object Between Ionizing Bar and Ground
electrode - Remove
Collecting Section of Cell
1. Dirty insulator(s) - Clean
2. Defective insulator(s) – Replace
3. Foreign Material Bridging Plates - Remove
4. Bent Plates – Straighten or Replace
High Voltage Leads
1. Disconnected High Voltage Lead Contacting Ground
- Reconnect
2. Defective Lead/Insulation Breakdown – Replace
Entire Lead
Indicating Light
Not Glowing
Short Circuit
Power Supply
Charred/Over Heated Components – Replace
Power Supply
Control
1. Disconnected Supply Line Power – Reconnect
2. Faulty indicting Light - Replace
Power Supply
1. Blown Fuse – Replace Power Supply
2. Disconnected Wire – Replace
3. Charred/Over Heated Components – Replace
Power Supply
Indicating Light
Not Glowing
Open Circuit
Electronic Air Cleaner
Housing
1. Electrical Interlock Switch Not Closed – Close
Access Door
2. Faulty Electrical Interlock Switch - Replace
Indicating Light
Flickering
High Resistance
Short
High Voltage Circuit
1. Ionizer High Voltage Lead Connected to Plate
Section and Plate Lead to Ionizer – Reconnect
Leads
2. Loose or Disconnected High Voltage Lead-Tighten
or Reconnect
3. Loose or Defective Intercell Connection (on Multicell
Units) – Tighten or Replace
4. Foreign Object Adrift in Ionizer or Plate Section of
Cell - Remove
Содержание AIR BOSS 60 Series
Страница 11: ......
Страница 12: ......
Страница 13: ......
Страница 14: ......
Страница 15: ......
Страница 16: ......
Страница 17: ......
Страница 18: ......
Страница 19: ......
Страница 20: ......
Страница 21: ......
Страница 22: ......
Страница 23: ......
Страница 24: ......
Страница 27: ......
Страница 28: ......
Страница 29: ......