Connectors 

For the electrical connection of the system, the cables end with connectors from Stäubli MC4 Evo2 (positive 
[+] and negative [-]). Further certified manufacturers and possible connector types can be found in the 
following overview: 

Type 

Manufacturer 

System Voltage 

Rated 
Current 

Temperature 
Rating 

PV-KST4-EVO 2/xy-UR; 
PV-KBT4-EVO 2/xy-UR 

Stäubli Electrical Connectors AG 

DC 1500V 

45A 

-40ºC to +85ºC  

05-8 

Zhejiang Renhe Photovoltaic Technology 
Co.,Ltd 

DC 1500V 

30A 

-40ºC to +85ºC  

PV-CY03L 

Zhejiang Chuangyuan Photovoltaic 
Technology Co.,Ltd 

DC 1500V 

30A 

-40ºC to +85ºC  

RHC2xyzu 

Zhejiang Renhe Photovoltaic Technology 
Co.,Ltd 

DC 1500V 

35A 

-40ºC to +85ºC  

QC4.10-cds 

QC Solar (Suzhou) Corparation. 

DC 1500V 

41A 

-40ºC to +85ºC  

PV-ZPJ030A 

The 40th Institute of China Electronic 
Technology Group Corporation 

DC 1500V 

38A 

-40ºC to +85ºC  

 
 

Cable

 

TRIMAX Solar PV modules are equipped with two pre-terminated, temperature and UV resistant cable leads 
(Rated 1500V DC, -40°C to 90 °C). The cross section of the cable is 4mm2 or 12AWG. Outer diameter is 
5mm to 7mm. The smallest bending radius of the cables must not be less than 43mm. Cable damage caused 
by excessive bending or by the cable management system is not covered by the warranty. 
When selecting the size of the cables connecting the module strings to the solar inverter, observe the 
electrical parameters specified on the module data sheet. To avoid overheating of the cables and the 
connectors, the cross-section of the cables and the capacity of the connectors must be selected according 
to the maximum system short-circuit current. The PV cable must be at least 4 mm2. Only use cables that are 
certified for use with PV systems.   
Observe the requirements of DIN VDE 0100-520. The standard applies to the selection and installation of 
cable and line systems. Cable and line installations are the totality of one and/or more cables or lines or 
busbars and their fastening means as well as their mechanical protection, if applicable. The standard contains, 
among other things, requirements for types of cable and line installations, selection and installation according 
to environmental influences, cross-sections of conductors, voltage drop in consumer installations, electrical 
connections, selection and installation to limit fires, proximity to other technical installations, selection and 
installation with regard to maintenance including cleaning. 
 
Wiring examples 

Single row vertical installation

 

Two rows of vertical installation

 

Horizontal installation

 

 

 

 

 

 

 

 

Table 5: Connection of Modules 

 

 

Содержание Solar TMX-MH7-120

Страница 1: ...1 ANLEITUNG 04_21 INSTALLATION AND OPERATING INSTRUCTIONS TRIMAX Solar GmbH Leitzstra e 45 70469 Stuttgart GERMANY Tel 49 711 490 66 278 Mail info trimax solar com Web trimax solar com...

Страница 2: ...ical installation 8 PLANNING AND INSTALLATION 9 Intended use 9 Shading 9 Tilt Angle 10 Glare behavior Glare assessment 10 Bifacial Modules 10 Electrical design 10 System dimensioning 11 Connectors 12...

Страница 3: ...es and ensure that this manual is accessible to the operator at all times Pass the manual on to any subsequent owner or user of the solar modules We reserve the right to make changes to the product sp...

Страница 4: ...the horizontal packing tapes 2 Place the pallets one by one 6 Carefully press the stack against a stand Not included 3 Remove the outer packing tapes 7 Cut the remaining packing tapes 4 Remove the co...

Страница 5: ...ove the lid and detach the outer carton 6 Carefully press the stack against a stand Not included 3 Remove the outer carton 7 Cut the remaining packing tapes 4 Place the stand on the glass side of the...

Страница 6: ...tructions including those given by other component suppliers Please contact our Technical Service if you have any questions about the instructions Fire protection TRIMAX Solar PV modules have been tes...

Страница 7: ...r open fire or flammable and explosive gases substances Only use plugs and sockets of the same manufacturer and type Only use devices plugs cables and support frames that are suitable for use in a sol...

Страница 8: ...current generation Do not install operate damaged modules as contact with the surface of the module or frame may cause electric shock Do not attempt to repair a module with broken glass or defective...

Страница 9: ...plants or trees or soiled by soil Lightning protection is recommended for PV systems that are to be installed in locations with a high probability of lightning strikes Shading The modules should not...

Страница 10: ...a professional provider for a glare assessment TRIMAX Solar high performance PV modules are coated with an ARC Anti Reflective Coating The glass coating with nano technology ensures that less light i...

Страница 11: ...orientation of the module For this purpose a complete simulation for the specific site with long term weather data is required Maximum number of interconnected PV modules When modules are connected i...

Страница 12: ...by the cable management system is not covered by the warranty When selecting the size of the cables connecting the module strings to the solar inverter observe the electrical parameters specified on...

Страница 13: ...d according to the manufacturer s instructions Design substructure For rooftop systems always make sure the roof structure is suitable before installing the modules on a roof Make sure that the module...

Страница 14: ...ing holes provided should be used Recommended to use corrosion resistant stainless steel screws 1 screw size and length M8x16mm 2 washer size M8 3 spring washer size M8 4 nut size M8 Torque 14 Nm 20 N...

Страница 15: ...unting holes Mounting with clamping systems Mounting with clamp systems can be done on both sides of the module frame Use at least 4 clamps per module two on both long sides or two on each short side...

Страница 16: ...ative 1800 Pa Table 9 Approved load capacity Clamping short side Mounting with insertion systems TRIMAX PV modules are compatible with insertion systems from selected manufacturers Installation method...

Страница 17: ...on profile Figure 15 Insertion system Minimum overlap Load capacity support on the long sides Figure 16 Load capacity Insertion system long side Module Type Maximum mechanical load TMX MH7 120 TMX MH7...

Страница 18: ...months to ensure they are clean secure and undamaged Check that mounting hardware terminal screws and grounding components are tight and not affected by corrosion Replacement modules must be of the s...

Страница 19: ...ne must not be used Module at end of life Please hand in electrical equipment that is no longer required for disposal at the designated collection points For information on where to dispose of the equ...

Страница 20: ...Insertion system long side 17 Figure 17 Load capacity Insertion system short side 17 List of Tables Table 1 Recommended unpacking method horizontally packed modules 4 Table 2 Recommended unpacking me...

Отзывы: