15
ANLEITUNG 04_21
Load capacity Screw inner mounting holes
Figure 10: Load capacity Screw inner mounting holes
Module Type
Maximum mechanical load
TMX-MH7-120
TMX-MH7-132
TMX-MH8-108
TMX-MH8-120
TMX-MH8-132
TMX-MH8-144
TMX-MH9-108
TMX-MH9-120
TMX-MH9-132
Positive: 5400 Pa
Negative: 2400 Pa
Table 7: Approved load capacity Screw inner mounting holes
Mounting with clamping systems
Mounting with clamp systems can be done on both sides of the module frame. Use at least 4 clamps per
module, two on both long sides or two on each short side of the module, depending on the orientation.
Depending on local wind and snow conditions, additional clamps may be required to ensure the module's load
capacity.
•
Module clamps must not come into contact with the front glass or deform the frame.
•
Take care to avoid shadows caused by module clamps.
Figure 11: End clamp
Figure 12: Center clamp