Page 36 of 121
Trilogy Communications
Mentor RG
5.6.5
AES Tone Sub- menu
Tone
Frequency
CH 1
< 25Hz - 20kHz >
CH 2
< 25Hz - 20kHz >
CH 3
< 25Hz - 20kHz >
CH 4
< 25Hz - 20kHz >
Amplitude
CH 1
< -120 - 0 dBFS >
CH 2
< -120 - 0 dBFS >
CH 3
< -120 - 0 dBFS >
CH 4
< -120 - 0 dBFS >
Mode
Channels 1-2
Off
On
CCIR
EBU
Lip Sync
Channels 3-4
As Ch 1-2
Direction
Channels 1-2
Std
Reverse
Channels 3-4
As Ch 1-2
Four simultaneous AES Groups are available from both the mainboard outputs and the
360-20-00 HD/3G-SDI option board if fitted.
The factory default setting for each Group is for the embedded AES to be enabled “On”. However,
to silence and should be configured using the Tone Mode menu to the right of this page.
Setting the Group Enable mode to “Off” will remove Tones and Source Ident from the stream,
regardless of any settings in the Tone Mode sub-menu.
Setting Tone mode to “Off” mutes the signal but retains the AES data within the stream. Setting
Tone Mode to “On” will provide continuous tone.