8.5 LEVER ORIENTATION
Remove the 2 lifting lugs
Unset the 3 cap screws [33]
Rotate the lifting [30] to the suited position
Set the 3 cap screws [33]
NOTE:
lifting lugs shall not be replaced on the safety valve.
33*
3
CAP SCREW
30*
1
LEVER
ITEM
QTY
DESRIPTION
Lifting lugs
33
30
8.6 OUTDOOR INSTALLATION
A pressure relief valve which is installed outdoors must be protected against any inclement environmental
conditions to ensure that it will provide the highest level of safety and will operate in the most effective &
responsive manner.
If the safety valve is exposed to hazardous weather conditions, ingress of dirt or other foreign matter or any
extremes of temperature conditions, please ensure that:
• The body is
insulated from the inlet neck to the cover. Excessive variations in temperature may
affect the set pressure or the body structure (thermal stress).
• A weathershield is fitted to prevent ice or snow accumulation or any foreign particles being
trapped between the spring coils. A weathershield may also be used to protect the spring
against sea or ocean spray.
8.7 INDOOR INSTALLATION
The outlet of the safety valve should not be connected to any equipment which might allow steam to be
ejected though the top cover and might in turn add risk of injury to personnel working close to the valve.
19
|
www.trilliumflow.com
STARFLOW V
™
PRESSURE RELIEF VALVE
SARASIN-RSBD
™