10.2.1 SET PRESSURE ADJUSTMENT
NOTE :
For insitu intervention, make sure the operating pressure is decreased as such to prevent the valve
top open during the adjusments.
In order to change or adjust the set pressure, cap assembly should be removed as per the instructions
which are provided within section 9.1.
To adjust the set pressure, note number of complete turns and mark on the screw to quickly locate the
correct zone of spring compression.
To change or adjust the set pressure, unscrew the set screw locknut (15).
• To increase the set pressure, screw the set screw downwards.
• To decrease the set pressure, unscrew the set screw upwards.
The set pressure adjustment must not be above ± 5 % of the original nameplate set pressure. Any
adjustment beyond this limit, please consult Trillium Flow Technologies
TM
so that we may check the possibility.
Once the adjustment is acceptable, screw the locknut (15) into place.
10.2.2 BLOWDOWN
NOTE :
For insitu intervention, make sure to gag the valve to prevent the disc to relief during the rings
adjustment. Otherwise the tools used for the adjustments could make the disc to open by accident. This
does not prevent the system pressure to rise and expose all the intervening personal near the valve.
To obtain a short blowdown (high closing pressure), the overlap ring (28) shall be lowered. For this
purpose, remove the overlap ring pin (90) and screw down the overlap ring by one notch. If the valve starts
to chatter, cease moving the overlap ring. Leave the overlap ring at the most recent position where the
valve was free from chatter. Start to move the lower adjusting ring down. If this still does not provide
satisfactory results, move the upper adjusting ring up.
To obtain a long blowdown, the steps should be the same but following the opposite direction for the rings:
Move the overlap ring upwards. If this does not provide satisfactory results, move the lower adjusting ring
upwards. If it is found to be essential, move the upper adjusting ring downwards.
The blowdown should always be as long as possible based upon the operating conditions. Short blowdown
ranges may lead to chattering.
10.2.3 UPPER AND LOWER RINGS ADJUSTMENT
Initial adjustments should be kept unless required as the above description..
In case of any issues with set pressure adjustment, please contact Trillium Flow Technologies
TM
aftersales department.
38
|
www.trilliumflow.com
STARFLOW V
™
PRESSURE RELIEF VALVE