Installation Guide for SecureMesh WAN® Gateway 2 - PL-0073A

Compliance Standard

Description

CSA-C22.2 No. 62368-1

CSA-C22.2 No. 60950-22

EN 62368-1, EN 60950-22

Climatic

Thermal: IEC 60068-2-1 /-2 /-14

Humidity: IEC 60068-2-30

Salt spray IEC 60068-2-11

Mechanical vibration and shock

IEC 60068-2-6

IEC 60068-2-27

Transportation vibration and drop

ISTA-6

Enclosure

NEMA Type 4X/IP66

Modification statement

Trilliant has not approved any changes or modifications to this device by the user. Any
changes or modifications not expressly approved by Trilliant could void the user's
authority to operate the equipment.

Trilliant n’approuve aucune modification apportée à l’appareil par l’utilisateur, quelle
qu’en soit la nature. Tous changements ou modifications qui ne sont pas approuvés
par Trilliant peuvent annuler le droit d’utilisation de l’appareil par l’utilisateur.

Interference statement

This device complies with Part 15 of the FCC Rules and Industry Canada license-
exempt RSS standard(s). Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.

Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux
appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions
suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de
l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d'en compromettre le fonctionnement.

Содержание GATE-2000

Страница 1: ...lation Guide for SecureMesh WAN Gateway 2 GATE 2000 Document Number PL 0073A Revision Preliminary 1 0 Date September 18 2020 Trilliant Holdings Inc 401 Harrison Oaks Blvd Suite 300 Cary North Carolina...

Страница 2: ...ociation EU EFTA compliance notices 10 Chapter 2 Overview 11 Ethernet cable 11 Kits and accessories 12 Supplies 13 Spare replacement parts 13 Chapter 3 Prepare for installation 14 Tools 14 Location re...

Страница 3: ...tion 37 Gateway parameters 38 Chapter 4 Mount the gateway 39 Attach the gateway to a pole or tower 39 Chapter 5 Commission the gateway 43 LED indicators 43 Startup in cold conditions 44 Accessing the...

Страница 4: ...in any form to any third party Trilliant reserves the right to make changes to this document or to any Products it describes at any time with or without notice Use duplication or disclosure by the U S...

Страница 5: ...low E mail support trilliant com Use this email address primarily for requesting access to the Support Portal or for resetting access credentials This email address is not a primary means of communica...

Страница 6: ...and equipment The instructions in this manual are not intended as a substitute for proper training in or adequate experience with safely operating the described equipment Only competent technicians w...

Страница 7: ...res Read all instructions before installing the GATE 2000 Warning The GATE 2000 should be installed and serviced only by personnel familiar with good safety practices when handling high voltage electr...

Страница 8: ...odifications not expressly approved by Trilliant could void the user s authority to operate the equipment Trilliant n approuve aucune modification apport e l appareil par l utilisateur quelle qu en so...

Страница 9: ...or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures l Reorient or relocate t...

Страница 10: ...e effects on human health and the environment which could otherwise arise from inappropriate waste handling For more information about collection and recycling of old products please contact your loca...

Страница 11: ...via Power over Ethernet PoE through a single weatherized Ethernet port located on the bottom of the enclosure The power sourcing equipment PSE used to power the GATE 2000 should be 802 3at compliant a...

Страница 12: ...000 and the associated PSE is 328 ft 100 m Trilliant recommends that a surge suppressor is installed between the PSE and the GATE 2000 The surge suppressor should be mounted adjacent to the GATE 2000...

Страница 13: ...L 0073A Supplies The following supplies are required for installation l Self fusing rubber insulation and sealing tape such as Scotch 130C or 2228 Rubber Mastic Tape l Electrical tape l Ground wire 10...

Страница 14: ...McMaster Carr Magnetic backed bull s eye level part number 3329A31 l Screwdrivers Phillips head sizes 2 and 3 l Screwdriver Flat blade medium size l Xacto knife l Diagonal cutters l 5 16 socket wrench...

Страница 15: ...ted view of the overhead sky for access to the strongest GPS signals At startup the GATE 2000 searches for a GPS signal If it cannot detect a signal it cannot complete startup establish wireless conne...

Страница 16: ...r down lead provided by the existing ground system at the site such as a part of the tower structure or the AC electrical system for the building see Figure 2 2 A 10 foot or longer copper clad ground...

Страница 17: ...allation requirements for lightning protection systems and the NFPA 780 standard for lightning protection Verify that all points of the ground system are tied together with less than 5 resistance betw...

Страница 18: ...en your company and Trilliant The contents may not be used or disclosed without the express written consent of Trilliant 18 Installation Guide for SecureMesh WAN Gateway 2 PL 0073A Gateway components...

Страница 19: ...0073A Figure 4 Accessory bag with screws bolts nuts and washers Screws bolts nuts and washers 1 1 4 28 hex head bolts 1 and 2 2 1 4 20 pan head screws 0 75 3 1 4 lock washers and flat washers 4 Ground...

Страница 20: ...and or licensors This document is provided subject to the confidentiality obligations set forth in the agreement between your company and Trilliant The contents may not be used or disclosed without th...

Страница 21: ...the clamp mount with the notch on the base of the GATE 2000 see Figure 6 3 Attach the clamp mount to the base using three of the 1 4 20 x 0 75 screws 1 4 lock washer and 1 4 a flat washer Do not inse...

Страница 22: ...fully against the bottom of the clamp mount 3 Hand tighten the six 1 4 28 bolts so that the stainless steel mounting bracket is parallel to the pole mount clamp and the spacing on each side is roughl...

Страница 23: ...build the DSC prior to mounting the GATE 2000 in the field Steps to Prepare the DSC 1 Remove the paper backing on the flat rubber seal and position the seal on the face of the connector body see Figu...

Страница 24: ...e for SecureMesh WAN Gateway 2 PL 0073A Figure 9 Align the ribs in the coupling nut 5 Feed the Cat6 cable through the strain relief round rubber seal and connector body in the order shown in Figure 10...

Страница 25: ...be used or disclosed without the express written consent of Trilliant 25 Installation Guide for SecureMesh WAN Gateway 2 PL 0073A 8 Slide the round rubber seal down the cable so that it sits fully in...

Страница 26: ...r CMJ8 PoE A C5E The following section describes the installation of the Citel CMJ8 POE A C5E 10 100 1000 surge suppressor Trilliant recommends mounting the surge suppressor below or near the GATE 200...

Страница 27: ...and Trilliant The contents may not be used or disclosed without the express written consent of Trilliant 27 Installation Guide for SecureMesh WAN Gateway 2 PL 0073A Figure 13 The Citel surge suppress...

Страница 28: ...he contents may not be used or disclosed without the express written consent of Trilliant 28 Installation Guide for SecureMesh WAN Gateway 2 PL 0073A Figure 14 Rubber gasket 5 Connect a 10 AWG ground...

Страница 29: ...contents may not be used or disclosed without the express written consent of Trilliant 29 Installation Guide for SecureMesh WAN Gateway 2 PL 0073A Figure 15 Ground wire installed on surge suppressor 8...

Страница 30: ...consent of Trilliant 30 Installation Guide for SecureMesh WAN Gateway 2 PL 0073A Figure 16 Assembled surge suppressor 11 A second ground wire is required to run from the base of the GATE 2000 to the...

Страница 31: ...nsent of Trilliant 31 Installation Guide for SecureMesh WAN Gateway 2 PL 0073A Figure 17 Attach the ground wire 14 To attach the ground wire to the GATE 2000 follow one of the steps below a If the gro...

Страница 32: ...sh WAN Gateway 2 PL 0073A Note For the surge suppressor to work properly there must be a low impedance path from the surge suppressor network to earth ground In the case of a wooden or insulated mount...

Страница 33: ...eement between your company and Trilliant The contents may not be used or disclosed without the express written consent of Trilliant 33 Installation Guide for SecureMesh WAN Gateway 2 PL 0073A Figure...

Страница 34: ...e Cat6 cable that connects to the PSE It should connect to JP1 19 Slide the black gasket back into place Note Ensure both RJ45 connectors are fully mated and latched 20 Double check that the nut on th...

Страница 35: ...t forth in the agreement between your company and Trilliant The contents may not be used or disclosed without the express written consent of Trilliant 35 Installation Guide for SecureMesh WAN Gateway...

Страница 36: ...out the express written consent of Trilliant 36 Installation Guide for SecureMesh WAN Gateway 2 PL 0073A Figure 20 Align the locking tab with the notch 25 Then slide the connector body and coupling nu...

Страница 37: ...or details on parameters and setting the configuration see the following applications and manuals l Administrator Guide for SecureMesh WAN and NEMS l Command Line Interface Reference The GATE 2000 can...

Страница 38: ...21 GATE 2000 power injector and test computer Gateway parameters 1 Using TeraTerm SecureCRT or a similar terminal emulator program establish a Telnet session to the gateway using its configured IP add...

Страница 39: ...73A Chapter 4 Mount the gateway This chapter describes the steps to mount the GATE 2000 on a pole or tower Attach the gateway to a pole or tower Prepare the mounting location on the pole or tower then...

Страница 40: ...osed without the express written consent of Trilliant 40 Installation Guide for SecureMesh WAN Gateway 2 PL 0073A l At the ends of the Y place the heads of the bolts on the extension arm l Place the t...

Страница 41: ...osed without the express written consent of Trilliant 41 Installation Guide for SecureMesh WAN Gateway 2 PL 0073A 4 Adjust the three bolts until the bracket is level 5 Place the vertical mounting pole...

Страница 42: ...licensors This document is provided subject to the confidentiality obligations set forth in the agreement between your company and Trilliant The contents may not be used or disclosed without the expre...

Страница 43: ...nclosure base When the GATE 2000 is powered up by the PSE a power on sequence starts automatically The STATUS LAN WAN and RSSI LEDs change color as the GATE 2000 progress through the boot up sequence...

Страница 44: ...link to another node is established the WAN LED displays in solid blue The RSSI LED changes color and blinks depending on the receive strength level from the neighboring node Refer to Table 7 for mor...

Страница 45: ...73A Table 4 STATUS function for normal operating mode Function Color s LED State Condition Status STATUS Green or red Off Power is off On green Power is on normal operation On green WAN LED flashes fr...

Страница 46: ...tallation Guide for SecureMesh WAN Gateway 2 PL 0073A Table 6 WAN function for normal operating mode Function Color s LED State Condition Status WAN Blue or red Off Disconnected from parent device off...

Страница 47: ...reen off No links Flashing amber at 1 Hz LRRSSI is 9 or lower On amber LRSSI is 10 19 Flashing green at 1 Hz LRSSI is 20 29 On green LRSSI is 30 or larger Accessing the CLI using WiFi The CLI interfac...

Страница 48: ...h for the SSID of the gateway the factory assigned MAC address The password Pre Shared Key PSK is Trilliantxxxxxx where xxxxxx are the last 6 characters of the MAC address Example l SSID 000ADBDA0175...

Страница 49: ...r the WiFi interface in order to access the CLI of the unit Subnet Mask Indicates the IP address mask of the WiFi interface Gateway Indicates the IP address of the gateway of the WiFi interface Channe...

Страница 50: ...icates the string of alphanumeric character that specifies the Service Set IDentifier which can be at most 32 characters long PSK Indicates the string of plain English passphrase characters that speci...

Страница 51: ...or disabled SSID Indicates the string of alphanumeric character that specifies the Service Set IDentifier which can be at most 32 characters long PSK Indicates the string of plain English passphrase c...

Страница 52: ...iFi interface is enabled or disabled SSID Indicates the string of alphanumeric character that specifies the Service Set IDentifier which can be at most 32 characters long PSK Indicates the string of p...

Страница 53: ...closed without the express written consent of Trilliant 53 Installation Guide for SecureMesh WAN Gateway 2 PL 0073A Chapter 6 Specifications This chapter provides reference information for the GATE 20...