www.trikdis.com
12
March, 2019
Cellular security control panel CG17
Schematics for connecting of the fuel level sensor Strela RS485
Configuring and preparing the fuel level sensor to work with the
CG17
It is mandatory to calibrate the fuel level sensor “STRELA S485” (http://strela-fls.com/products/fuel_level_sensors_strela.html)
using the manufacturer’s calibration software
DUTConfig
(http://strela-fls.com/programs.html) and specify the fuel tank’s
capacity – otherwise the sensor’s measurements can be imprecise.
1.
Connect the fuel level sensor to a computer using a programming adapter. Press the „brown” button on the adapter to
make the green indicator in the RS-485 UART section light up.
2.
Launch the
DUTConfig
program. Choose “
Interface sensor
”.
3.
Set
View
mode
Standart
.
4.
Click
Connect
and wait.
5.
When the sensor is connected to
DUTConfig
, a box
Connection: on
appears.