When the alarm is armed, a violation of the “Delay” zone starts the entry time counter, during which the alarm must
be disarmed. If the alarm is still not disarmed when the time is up, outputs OUT “Siren” and “Flash” are turned on and
alarm reports are sent.
o
Interior
– for connecting a movement sensor to the entry door.
When the alarm is armed, if the “Interior” zone is violated, OUT outputs “Siren” and “Flash” are turned on and alarm
reports are sent.
If the alarm is armed and the first zone to be violated is the “Delay” zone, the “Interior” zone may also be violated
during the set entry time. If the alarm is not disarmed when the set entry time is up, outputs OUT “Siren” and “Flash”
are turned on and alarm reports are sent.
o
Instant
– for connecting movement sensors. If the “Instant” zone is violated when the alarm is armed, OUT outputs
“Siren” and “Flash” are turned on and a message about the alarm being triggered is sent.
o
Fire
– for connecting fire sensors. If this zone is violated, OUT outputs “Siren” and “Flash” are turned on immediately
and a message about the event is sent.
o
Keyswitch
–
for connecting a keypad or other switch. If the switch violates this zone the security alarm will be armed
or disarmed. The alarm will be armed again after the set
Exit time
passes.
o
24 hours
– for connecting glass break and tamper detectors. If this zone is violated, OUT outputs “Siren” and “Flash”
are turned on immediately and a message about the event is sent.
o
Silent
– if the alarm armed and this zone is violated, an event message will immediately be sent, but “Siren” and “Flash”
output signals will not be formed.
o
SIlent 24h
– for connecting panic buttons. If this zone is violated, an event message will immediately be sent regardless
of the state of the security system, but “Siren” and “Flash” output signals will not be formed.
Type
– choose the type of circuit connected to the zone input IN from the list: NC – normally closed, NO – normally open,
EOL – end of line 10 kΩ resistor.
Bypass
– tick this box if you want to bypass a zone and ignore when it is triggered.
Force
– tick this box if you want to allow arming the security system with an open zone. If the alarm is armed, violating
the zone that is in “Force” mode will trigger the alarm.
CMS
– if the box is ticked, event messages for this zone will be sent to CMS (Central monitoring station) and to
Protegus
cloud.
Delay
–input IN zone reaction time, in miliseconds.
CID code
– Contact ID codes for events. The code will be set automatically when you choose a zone definition.
“SMS & Call reporting“ tab
This window will only show if at least one user is added in the “Users & Reporting” window
.
Zn
– zone number with event identification word. Can be
“Event”
or
“Restore”
.
SMS text
– description of the zone event that will be used in SMS messages sent to users.