Cellular security control panel CG17
Settings group “Fuel sensor settings”
Enable fuel loss detection
– ticking the box will enable fuel level monitoring.
Start fuel loss detection when engine started
– if the box is ticked, fuel level monitoring will begin when the engine is
started. The engine start signal must be sent to the
CG17
input (zone) that is chosen in the next setting.
Zone number for engine start
– specify the number of the
CG17
input (IN) that the engine start will enable.
Fuel consumption rate
– enter the fuel consumption rate.
The user will be informed about sudden fuel level changes with an SMS message. The user can edit the text of the SMS message.
Description of the operation of the fuel level sensor. The fuel level sensor
Strela RS485
is connected to the
CG17
(see
2.10 “Schematics for connecting of the fuel level sensor Strela RS485”
). The measuring parameters are set for the
CG17
. The
fuel level sensor starts measurements:
1.
When the box "Enable fuel loss detection" is ticked. When the power is turned on for the
CG17
, the fuel level sensor
starts to monitor fuel consumption. Measurements stop when the power for the
CG17
is turned off.
2.
The boxes “Enable fuel loss detection” and “Start fuel loss detection when engine started” are ticked. Also, the number
of the input (IN) that will start fuel level monitoring when it is enabled (engine is started) must be specified. When the
input (IN) is restored (engine off) fuel level monitoring will be stopped.
Every time the fuel level sensor is turned on, it measures the current fuel level and compares it to the fuel level that was saved
to memory before the sensor was turned off. If the current fuel level is lower, the
CG17
sends messages about fuel loss to the
security company and/or to users.
During operation, the fuel level sensor measures the fuel level every time interval and compares it to the consumption rate. If
the fuel consumption in a time interval is larger than the entered fuel consumption rate, the
CG17
sends messages to the security
company and/or to users.