Cellular security control panel CG17
“Modules” window
Settings group “RS485 modules”
ID
– module’s number on the list.
Module
– choose the modules being used (modules
iO
,
iO-WL
,
TM17, iO-8, RF-SH, FLS
) from a list of modules.
Serial No.
– mandatory 6-digit number that can be found on stickers on the casing of the module and on the packaging.
Area
– assign the module to an area (the
TM17
will show the state of the area it is assigned to and also the state of the
zones assigned to the area).
Name
– you can give a name to the module.
Firmware version
– the firmware version will be shown once the
CG17
detects the connected module.
Settings group “Internal modules”
Module type
– choose the GPS module that is being used.
Coordinates reporting every __ min, when no movement or every __ sec, when movement or selected zone in alarm
–
specify intervals for sending coordinates when in ordinary mode and when movement is detected or the alarm is triggered
in the zone.
Movement detection
– if the box is ticked, the alarm will be triggered if the difference between coordinates is larger than
specified. Coordinates will be sent more often.
Coeficients for smoothness, Slow smooth
– averaged coordinates are sent when there is no movement (the average is
taken from the specified number of coordinates – 256 or other specified number).
Coeficients for smoothness, Fast smooth
– averaged coordinates are sent when there is movement or the zone is in
alarm state (the average is taken from the specified number of coordinates – 8 or other specified number).
Generate alarm when movement detected
– if the box is ticked, the CID event code is sent to the CMS and the user to
the Protegus, when movement is detected.
Force movement reporting on zone alarm
– specify the security system’s zone to which a sensor is connected. If the
sensor is triggered (interpreted as a zone alarm) the
CG17
sends coordinates more often.
Stop reporting after alarm when no movement for __ min
– specify time interval (in minutes). If the coordinates do not
change and there is no zone alarm during this time, coordinate sending returns to ordinary mode.
Messages with the coordinates are sent to the monitoring program Monas MS.