Page 9
Miniguard IID
PROGRAMMING (Continued)
(L) Programming Output Relay 1 “ON” Time:
This feature allows time clock control of output Relay
1. You may set the relay to activate at a certain time of
day and deactivate at a later time of the same day. Also,
you may set this daily on\off action to happen within a
certain part of the week; i.e. Tuesday through Friday.
Note: A military time format (24 hour clock) is used in
clock programming .
To program output Relay 1, do the following:
1. Unit must be in Program Mode (see section A).
2. Enter "# 4"
3. Enter Start Time
(Use military format of
hours:minutes, i.e. “0600” , “1500”). Entry must be
four digits.
4. Enter End Time
(same four digit format as above).
5. Enter start day and End Day
("1 thru 7" means
Monday through Sunday). For example, entering 24
would set the clock for Tuesday through Thursday.
You will hear two beeps.
Note: Day entries must be 2 digits (start and end day).
Note: To program the relay to operate only one day a
week, enter the digit for that day twice (“6 6” means
Saturday only).
6. Enter "# #" to exit Program Mode, otherwise,
continue programming by entering the desired
function code.
(M) Programming Output Relay 2 “ON” Time:
This feature allows time clock control of output Relay
2. You may set the output relay to activate at a certain
time of day and deactivate at a later time of the same
day. Also, you may set this daily on\off action to happen
within a certain part of the week; i.e. Tuesday through
Friday.
Note: A military time format (24 hour clock) is used in
clock programming .
To program Output Relay 2, do the following:
1. Unit must be in Program Mode (see section A).
2. Enter "# 5"
3. Enter Start Time
(Use military format;
hours:minutes, i.e. “06:00” , “15:00”). Entry must be
four digits.
4. Enter End Time
(same four digit format as above).
Enter Start Day and End Day
("1 thru 7" means
Monday through Sunday). For example, entering 24
would set the clock for Tuesday through Thursday.
You will hear two beeps
Note: Day entries must be 2 digits (start and end day).
Note: To program the relay to operate only one day a
week,enter the digit for that day twice (“6 6” means
Saturday only).
5. Enter "# #" to exit Program Mode, otherwise,
continue programming by entering the desired
function code.
(N) Master Erase Procedure:
This procedure allows selective or complete deletion of
all data in the Miniguard IID’s memory. Also, it is
possible to reset the Miniguard IID back to its factory
defaults (presets).
Note: Use caution when performing these steps.
1.Unit must be in Program Mode(see section A),
2. Enter " #
✽
".
3. Enter "0" if you wish to erase all data and reset
unit back to factory defaults.
4. Enter "1" if you wish to erase all Entry Codes.
5. Enter "2" if you wish to erase all Resident Code/
telephone numbers.
6. Enter "3" if you wish to reset the unit back to
factory defaults, leaving all other memory intact.
Upon completion of the full master erase sequence, you
will hear a long series of beeps.
Note: Master Erase time will vary greatly depending on
memory type, usage and capacity.
Содержание MiniGuard IID