(G) Entering Cards:

This function requires the installation of the Card Reader
Interface option and a card reader. Card access makes it
possible for the user to use an access card at the unit and
gain entry.  Each card entered is converted to a standard
4 digit Entry Code and goes into “Direct Entry Code
memory”.

1. Unit  must be in Program Mode (see section A).

2. Enter “# 1”.  (You are in 'Batch Mode).

3. Pass a card through the card reader.

You will hear one beep.

This indicates card number accepted. Three 'beeps'
indicates card not accepted.

For next card repeat step 3 until all cards are done.

Note:  If 3 beeps are heard, that card cannot be used
because it already appears in memory. Batch Mode is
terminated on this or any fault.

4. Press “#” when card programming is complete,
to return to main Program Mode.

5. Enter "# #" to exit Program Mode, otherwise,
continue programming by entering the desired
function code.

(H) Deleting Cards:

If the 4 digit value assigned to the card is known, it can
be removed from memory with the same procedure as
Deleting Entry Codes.  Otherwise, from Program Mode:

1. Unit  must be in Program Mode (see section A).

2. Press“#2” and pass the card to be deleted
through the reader.

You will hear one beep.

This indicates successful removal.

Note:  Three beeps indicates that the card was not in
memory, and the Batch Mode is aborted.

3. Press “#2” to re-enter Batch Mode.

                                   - or -

If the card has been successfully removed

4. Press“#” to return to normal Program Mode
then, continue programming by entering the
desired function code.

5. Enter "# #" to exit Program Mode, otherwise,
continue programming by entering the desired
function code.

(I) Programming Site Identification Code:

In the case of multi-unit installations, the Site
Identification Code makes it possible for the party
receiving a call from a Miniguard IID to identify which
“gate” is calling.

1. Unit  must be in Program Mode (see section A).

2. Enter "# 8"  and the 4 digit number.

You will hear two beeps.

3. Enter "# #" to exit Program Mode, otherwise,
continue programming by entering the desired
function code.

(J) Programming Tamper Code:

This feature can be used to alert a manager if the unit is
being tampered with.  (Four unsuccessful or invalid
attempts to enter the programming mode constitutes a
tamper.)  The unit looks up the Resident Code stored in
“tamper” and dials the phone number associated with

that resident code.

1. Unit  must be in Program Mode (see section A).

2. Enter " #  6"  and the Resident Code that you
have chosen.

You will hear two beeps.

 3. Enter "# #" to exit Program Mode, otherwise,
continue programming by entering the desired
function code.

(K) Programming Time-of-Day Clock:

The time of day clock allows automatic operation of
the output relay.

1. Unit  must be in Program Mode (see section A).

2. Enter  " #  3 " .

3. Enter the Month.  (01=Jan., 02=Feb.,... 12=
Dec).
  

Be sure to include the zeros when setting the

clock.

4. Enter the Monthly Date.  (01 thru 31).

5. Enter the last two digits of the Year  

(i.e., 1995

would be 95).

6. Enter the Hour. 

Use military time; 00 thru 23 hrs.

7. Enter the Minutes. (00 thru 59).

8. Enter the Day of Week. 

(1= Mon.,  2=Tues, ...

7=Sun.).

You will hear two beeps.

Note:  A military time format (24 hour clock) is used
clock programming .

9. Enter "# #" to exit Program Mode, otherwise,
continue programming by entering the desired
function code.

Содержание MiniGuard IID

Страница 1: ...der Circle Corona CA 92880 951 371 1730 Facsimile 951 371 2592 www TrigonElectronics com October 28 2004 Multi Number Handsfree Telephone Entry System INSTALLATION and PROGRAMMING INSTRUCTIONS MiniGuard IID TM ...

Страница 2: ...hone Numbers 7 Programming Entry Codes 7 Changing the Factory Program Code 7 Deleting Entry Codes 7 Entering Access Cards 8 Deleting Cards 8 Programming Site ID Code 8 Programming Tamper Code 8 Programming Time of Day Clock 8 Programming Output Relay 1 On time 9 Programming Output Relay 2 On time 9 Master Erase 9 Editing the Electronic Display 10 Remote Editing of Display 11 OPERATION Calling a Te...

Страница 3: ... IID has a capacity of up to 400 telephone numbers and up to 400 personal entry codes and is Analog Port compatible It features a LCD directory for integrated design It is constructed for rugged outdoor use Its long lasting brushed finish stainless steel housing complements its thin design lines A matching flush mount trim ring or lighted hood may be selected to add the finishing touches to an ins...

Страница 4: ...g 5 for wire connection information 2 Do not energize wires until installation is completed 3 Do not power any other device from the Trigon s 12 VAC transformer If a substitute transformer is used be sure it is rated 12 VAC 20VA UL Class 2 listed The 12 VAC input power wires should be 18AWG 600V insulated wire This should be sufficient for distances up to 200 feet 4 Ground the unit by attaching a ...

Страница 5: ...H GROUND TELEPHONE LINE MICROPROCESSOR AUDIO SPEAKER VOLUME PRIMARY RELAY 12V AC DC NO C NC RELAY INPUT POWER 5 Amp MAX 1 4 Amp NC MEMORY P S G C NO Telephone line cabling Voice Grade 24 to 48V 22AWG Shielded or Twisted up to 2400 Busy Com Printer In DB 9 Computer In Com Out Keypad Secondary Relay Contacts RTS Microphone Sensitivity Adjustment Secondary Relay 5 Amp MAX PG EARPHONE MOUTH SPEAKER Mi...

Страница 6: ...TUP SYSTEM SETUP SYSTEM SETUP SYSTEM SETUP SYSTEM SETUP General Programming Information The Initial Setup for the Miniguard IID has been programmed at the factory These factory default settings may be changed to better suit your particular application If you decide to alter these settings follow the instructions below It is important that each programming step be taken in order When reprogramming ...

Страница 7: ...amming Entry Codes Entry Codes make it possible for the resident to enter a Code P I N number at the unit and gain access without placing a call 1 Unit must be in Program Mode see section A 2 Enter 1 3 Enter any 4 digit number between 0000 and 8999 You will hear two beeps indicating the number has been recorded in the Miniguard IID s memory Repeat steps 2 and 3 until you are finished Note Three be...

Страница 8: ...red function code 5 Enter to exit Program Mode otherwise continue programming by entering the desired function code I Programming Site Identification Code In the case of multi unit installations the Site Identification Code makes it possible for the party receiving a call from a Miniguard IID to identify which gate is calling 1 Unit must be in Program Mode see section A 2 Enter 8 and the 4 digit n...

Страница 9: ...hin a certain part of the week i e Tuesday through Friday Note A military time format 24 hour clock is used in clock programming To program Output Relay 2 do the following 1 Unit must be in Program Mode see section A 2 Enter 5 3 Enter Start Time Use military format hours minutes i e 06 00 15 00 Entry must be four digits 4 Enter End Time same four digit format as above Enter Start Day and End Day 1...

Страница 10: ...tion for letter T Enter 4 2 key 4 SECOND position for letter H Enter 1 1 key 1 FIRST position for space Enter 5 1 key 5 FIRST position for letter J The symbol is displayed so use a single 0 to skip the and move to the next charcter location Use 11 11 11 etc to replace the remainder of the periods on that line with SPACES 4 Press to continue with the next listing Character Table A 21 N 62 Space 11 ...

Страница 11: ...tion A 2 Press 92 to enter the display edit mode You will hear two beeps 3 Press the resident code to be edited You will hear one beep 4 Enter the resident s name by pressing a two digit number for each character to appear on the display The name entry may be up to 16 characters Use the numbers from the Character table that follows Note If modifying a name simply overwrite the existing name Use sp...

Страница 12: ... located next to the tenant s name on the LCD directory You will hear tenant answer Granting Visitor Entry Answer telephone and identify visitor You may choose from the following options fig 4 1 Enter 0 to activate Relay 1 and disconnect 2 Enter 8 to activate Relay 2 and disconnect 3 Enter 9 to activate Relay 2 and continue conversation Note On rotary telephones 5 or higher can be used to activate...

Страница 13: ...rs choose from the following 1 Enter 0 for touch tone echo test Unit will echo any touch tone you send with your phone 2 Press to escape from this test 3 Enter 1 for memory test One tone good two tones bad 4 Enter 2 for touch tone sequence Unit answers by transmitting touch tones 1 through 9 and Printer Operation Optional The Miniguard IID can support an audit log output to a remote serial printer...

Страница 14: ...t contacts and wires are clean and tight CANNOT PROGRAM 1 Incorrect lost program code 2 Not entering before program code 3 Try NO DIAL TONE troubleshooting procedures 4 Keypad damaged Check for vandalism 5 Check that the Program Prom Microprocessor is fully seated LOSES MEMORY 1 Electrical noise on power line Install EMI RFI filter 2 Excessive electrical noise from strike Use low current strike 3 ...

Страница 15: ...e accepted Send Site ID Code iiii error not set Note Warning tone occurs 10 seconds before auto hang up Program Phone Number s Press rrrr nnn nnnn Add Entry Code Press 1 eeee memory full Delete Entry Code Press 2 eeee already in memory Set Clock Optional Press 3 MMDDYhhmmd Set Primary Relay on off schedule Press 4 hhmm hhmm d d start and stop time FROM day and TO day Set Secondary Relay on off sch...

Страница 16: ... minutes Programming Directly on keypad or remotely by DTMF tones Power 120VAC 12VAC 40VA Class 2 trans former included Output Ratings Power Relays 5 AMPS 30 VDC 250VAC 1 8 HP 120VAC Alarm Shunt Relay 250ma 12VAC Output Duration Programmable momentary to 45 seconds or latched Manual Inputs Keypad direct entry or postal lock box push to exit button Telephone Line Standard touch tone or rotary Dedic...

Страница 17: ...Page 17 Miniguard IID ...

Отзывы: