![TrickleStar TS2501 Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/tricklestar/ts2501/ts2501_user-manual_1162084015.webp)
15
Step 05 - Test the Connection of Each
Output
This step helps you to check if the output
terminals were connected correctly and securely.
During the connection test, check if your HVAC
equipment connected to the respective output
terminal is turned on.
1. Rotate the Jog dial clockwise to turn on the
output as follows:
After you rotate the Jog dial, there may be a few
seconds delay before the HVAC equipment turns on.
This is not a malfunction.
●
: All outputs off
●
: Only Y1 is on, all others off
●
: Only Y2 is on, all others off
●
: Only W1 is on, all others off
●
: Only W2 is on, all others off
●
: Only G is on, all others off
●
: Only O/B is on, all others off
●
: Only ACC is on, all others off
Fig 15-A