background image

Technical Specification

Overall Dimension

180 x 80 x 40mm.

Power Supply

4 x 1.5V Size AA batteries with power consumption 

16mA. (Included)

Display

Special 4 x 16 character big screen LCD

lattice (valid visual field 61.6 x 25.2mm).

Type of test Cable

STP/UTP twin twisted cable. Coaxial cable, telephone 

line.

Working Ambient Temp.

-10⁰ C to + 60⁰ C.

Tester Port

Test RJ45 master port (M), test LOOPBACK RJ45 port 

(L), far-end Recogniser RJ45 port (R). The BNC and 

RJ11 adaptor accessories can be used to measure and 

check the continuity of coaxial cable and telephone 

lines.

Twin Twisted Cable Length

Scope: 1 - 350m, (3 - 1,200ft)

Calibration Accuracy

3% (+/- 0.5m or +/- 1.5ft) (calibrating cable >5m)

Shipment Accuracy

5% (+/- 0.5m or +/- 1.5ft) (AMP, AT&T Class 5 cable)

Display

Meters or feet.

Length Calibration

The user can set the calibration factor with a given 

length of cable. The length of the calibrating cable 

should be more than 5m.

Wire Sequence and Locating

Cable Error

Check errors such as open circuit, short circuit, reverse 

connection, cross-over or cross-talk interference.

Locating Cable

8 far-end passive test jacks (ID 1 ≥ ID 8)

Automatic Time-Delay Shut Off Time

30 minutes

14

Содержание 157011

Страница 1: ...LAN Network Tester Part No 157011 Operating Manual TRIAX your ultimate connection...

Страница 2: ...esult or test results could be affected Ensure that the batteries are correctly inserted Refer to the polarity symbols within the battery compartment To ensure efficient use and increase battery life...

Страница 3: ...nd Key Description 4 Operation Procedures 5 Wiring Diagrams and Test Functions 6 Pair and Length Measurement 9 Coaxial Cable and Telephone Line Measurement Function 11 Calibration and Setup Function 1...

Страница 4: ...ors such as open circuit short circuit jumper wire reverse connection or cross talk interference can be detected Locates the wiring or connection error Measures the cable length and estimates the dist...

Страница 5: ...d if the tester is not used for a long time to prevent the battery pack from leaking which will result in corrosion Note disposal advice on page 1 LAN Network Cable Tester Front Panel and Ports Interf...

Страница 6: ...L and R and locate errors Pair and Length Pair and length measurement to verify cable length pen circuit distance pairing and cross talk interference Coax Tel Coaxial cable and telephone line measurem...

Страница 7: ...ress the p or q key to restart the test or press the PAIR L key to return to the main menu Always correct a short circuit fault first and then start further test measurements Test 2 Far end matcher ID...

Страница 8: ...p or q key to restart the test or press the PAIR L key to return to the main menu Test 4 Wiring diagram WIREMAP display when there is an open circuit at the far end of the cable On the R line pins 3...

Страница 9: ...th measured from the near end plug Test 6 Wiring diagram WIREMAP display when there is an open circuit in the middle of the cable The display will show a wiring diagram WIREMAP as shown below if there...

Страница 10: ...ay an image typical to that shown below as the measurement is being made Note Due to different technical parameters in various branded cables the user should carry out the LAN Network Cable Tester Dyn...

Страница 11: ...the PAIR L key to return to main menu Test 3 Abnormal pair and length PAIR LENGTH display If Paired and Unpaired lines are detected in the pair and length PAIR LENGTH measurement the LAN Network Cable...

Страница 12: ...below It will display OPEN if there are any open circuits or if the coaxial cable or telephone line is not connected It will display SHORT if there are any short circuits Press the p or q key to repe...

Страница 13: ...bration section below QUIT Return to the main menu Dynamic Calibration CALIBRATION function Note A shortcut to entering the Dynamic Calibration function is to press and hold the PAIR L key while switc...

Страница 14: ...lso prompted as to whether they want to continue calibrating or not Press the q key to select No and exit the calibration function Press the p key to select Yes and repeat the measurement If there is...

Страница 15: ...an be used to measure and check the continuity of coaxial cable and telephone lines Twin Twisted Cable Length Scope 1 350m 3 1 200ft Calibration Accuracy 3 0 5m or 1 5ft calibrating cable 5m Shipment...

Страница 16: ...Issue 2 Triax reserves the right to change the specifications without prior notification...