Calibration and setup, (SETUP), function:
When the Calibration and Setup function is selected, the LAN Network Cable Tester
will show a display typical to that shown below:
Press the
p
or
q
keys to move the cursor ‘->’ indicator up and down to the
required item and then press ‘PAIR&L’ to select the required setup function.
UNIT - This is used to set up the length unit. The options are metre (m) and feet (ft).
CALIBRATION -Selects the Calibration function (See Calibration section below).
QUIT - Return to the main menu.
Dynamic Calibration, (CALIBRATION), function:
Note: A shortcut to entering the ‘Dynamic Calibration’ function is to press and hold
the ‘PAIR&L’ key while switching on the LAN Network Cable Tester.
For an accurate measurement of cable length, the calibration operation should be
carried out as follows.
When Dynamic Calibration is selected, the tester shall display the following:
Press the
p
key to select ‘Yes’ and continue with the calibration.
Press the
q
key to select ‘No’ and exit the calibration function.
Insert a cable of given length into the ‘M’ port, there is no need to insert the far-end
recogniser.