Pair and Length measurement (PAIR & LENGTH) function:

Whether or not there is a far-end recogniser, (ID), at the far-end of the cable, the 

LAN Network Cable Tester is capable of carrying out a ‘Pair and Length’ (PAIR 

& LENGTH) measurement.  Therefore, the far-end recogniser, (ID), can remain 

connected during a wiring diagram, (WIREMAP), and pair and length (PAIR & 

LENGTH) measurement. This avoids it being repeatedly inserted and removed. 

When the pair and length (PAIR & LENGTH) measurement function is selected, the 

LAN Network Cable Tester display will display an image typical to that shown below 

as the measurement is being made:

Note:  Due to different technical parameters in various branded cables, the user should carry 

out the LAN Network Cable Tester Dynamic Calibration function before making a length 

measurement. (See page 12)

Test 1: Short circuit (SHORT)

The LAN Network Cable Tester will display an image typical to that shown below if 

there are any short circuits on the cable or terminal, (12 short circuits are shown in 

the example below).

(The tester cannot show the exact location of the short circuit). Press the 

p

 or 

q

 

key to restart the test or press the ‘PAIR&L’ key to return to the main menu.  

Always correct a short circuit error first and then start further test measurements.

9

Содержание 157011

Страница 1: ...LAN Network Tester Part No 157011 Operating Manual TRIAX your ultimate connection...

Страница 2: ...esult or test results could be affected Ensure that the batteries are correctly inserted Refer to the polarity symbols within the battery compartment To ensure efficient use and increase battery life...

Страница 3: ...nd Key Description 4 Operation Procedures 5 Wiring Diagrams and Test Functions 6 Pair and Length Measurement 9 Coaxial Cable and Telephone Line Measurement Function 11 Calibration and Setup Function 1...

Страница 4: ...ors such as open circuit short circuit jumper wire reverse connection or cross talk interference can be detected Locates the wiring or connection error Measures the cable length and estimates the dist...

Страница 5: ...d if the tester is not used for a long time to prevent the battery pack from leaking which will result in corrosion Note disposal advice on page 1 LAN Network Cable Tester Front Panel and Ports Interf...

Страница 6: ...L and R and locate errors Pair and Length Pair and length measurement to verify cable length pen circuit distance pairing and cross talk interference Coax Tel Coaxial cable and telephone line measurem...

Страница 7: ...ress the p or q key to restart the test or press the PAIR L key to return to the main menu Always correct a short circuit fault first and then start further test measurements Test 2 Far end matcher ID...

Страница 8: ...p or q key to restart the test or press the PAIR L key to return to the main menu Test 4 Wiring diagram WIREMAP display when there is an open circuit at the far end of the cable On the R line pins 3...

Страница 9: ...th measured from the near end plug Test 6 Wiring diagram WIREMAP display when there is an open circuit in the middle of the cable The display will show a wiring diagram WIREMAP as shown below if there...

Страница 10: ...ay an image typical to that shown below as the measurement is being made Note Due to different technical parameters in various branded cables the user should carry out the LAN Network Cable Tester Dyn...

Страница 11: ...the PAIR L key to return to main menu Test 3 Abnormal pair and length PAIR LENGTH display If Paired and Unpaired lines are detected in the pair and length PAIR LENGTH measurement the LAN Network Cable...

Страница 12: ...below It will display OPEN if there are any open circuits or if the coaxial cable or telephone line is not connected It will display SHORT if there are any short circuits Press the p or q key to repe...

Страница 13: ...bration section below QUIT Return to the main menu Dynamic Calibration CALIBRATION function Note A shortcut to entering the Dynamic Calibration function is to press and hold the PAIR L key while switc...

Страница 14: ...lso prompted as to whether they want to continue calibrating or not Press the q key to select No and exit the calibration function Press the p key to select Yes and repeat the measurement If there is...

Страница 15: ...an be used to measure and check the continuity of coaxial cable and telephone lines Twin Twisted Cable Length Scope 1 350m 3 1 200ft Calibration Accuracy 3 0 5m or 1 5ft calibrating cable 5m Shipment...

Страница 16: ...Issue 2 Triax reserves the right to change the specifications without prior notification...

Отзывы: