iii
TABLE OF CONTENTS
PRODUCT AND SAFETY INFORMATION ......................................................................... VII
CHAPTER 1 - PRE-INSTALLATION REQUIREMENTS ........................................................ 1
1.1.
Code Compliance ............................................................................................................................ 1
1.2.
Code Restrictions ............................................................................................................................ 1
1.3.
Operating Restrictions .................................................................................................................... 1
1.4.
Locating Water Heater ....................................................................................................................2
1.5.
Recommended Clearances ............................................................................................................2
1.6.
Residential Garage Installations ....................................................................................................2
CHAPTER 2 - DOMESTIC PIPING .......................................................................................3
2.1.
Temperature & Pressure (T&P) Relief Valve .................................................................................3
2.2. Standard Installation ......................................................................................................................3
2.3. Commonwealth of Massachusetts Installation ............................................................................4
2.4. T&P Relief Valve Discharge Piping .................................................................................................4
2.5.
Domestic Drain Valve ......................................................................................................................4
2.5.1 Standard Installation .............................................................................................................4
2.5.2 Commonwealth of Massachusetts Installation ..................................................................5
2.6. Manual Air Vent ..............................................................................................................................5
2.7.
Thermal Expansion .........................................................................................................................5
2.8. Water Hammer ................................................................................................................................5
2.9.
Vacuum Breaker ..............................................................................................................................5
2.10. General Piping .................................................................................................................................5
2.11. Domestic Piping ..............................................................................................................................5
2.12. Thermostatic Mixing Valve .............................................................................................................6
2.13. Recirculation Piping ........................................................................................................................6
2.14. Storage Tank Application ...............................................................................................................6
CHAPTER 3 - WATER HEATER START-UP ..........................................................................9
3.1.
Filling the Inner (Domestic Water) Tank ........................................................................................9
3.2. Filling the Outer (Boiler Water) Tank .............................................................................................9
3.3. Setting the Thermostatic Mixing Valve .........................................................................................9
3.4. Domestic Hot Water EZ Setup
.............................................................................................11
3.5. DHW Frost Protection ...................................................................................................................12
3.6. CTRLMax Factory Settings ..........................................................................................................12
Содержание PRESTIGE Excellence 110
Страница 2: ...INTENTIONALLY LEFT BLANK...
Страница 6: ...INTENTIONALLY LEFT BLANK...
Страница 24: ...INTENTIONALLY LEFT BLANK...
Страница 28: ...20 CHAPTER 6 CHAPTER 6 WATER HEATER SPECIFICATIONS 6 1 Performance...
Страница 29: ...21...
Страница 30: ...22...
Страница 31: ...23...