IQ41x Installation Instructions - Confi guring TG201251 Issue 5, 22-Aug-2014

 3

InstallationInstructions-Configuring

IQ41x

 12

ChecktrendCurrentLoopnetworkLeDs

(IQ41x/LAN only)

10s

 9

Switch on

 8

CloseRotatingCovers

 10

CheckWatchdog/PowerLeDs

Normal operation indication

Watchdog
Power

Fault indications

Watchdog

Device faulty reset to defaults, see ‘Reset 

to Defaults on page 12.

Power

Check input power supply

Note: All LEDs illuminate for several seconds after switch on.

2

ConFIguRAtIonPRoCeDuRe

(continued)

22

23

24

25

RX+

28

29

WMB

RX- TX+ TX-

RX

OK

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

1

2

3

230V

19

4

5

10

24V

0V

0V

0V

0V

0V

0V

9

8

6

7

1

2

3

Watchdog

(red)

Power

(green

 11

CheckethernetLeDs

(if Ethernet is connected)

Normal operation indication

RX (yellow)

   

 or 

OK (green)

Fault indications

OK (green)

Check Ethernet 

Note: All LEDs illuminate for several seconds after switch on.

oK

(green)

RX

(yellow)

Normal operation indication

RX

TX

Fault indications

RX

No TX signal from previous device on network 

– check device/wiring

TX

Signal  not  reaching  RX  on  next  device  on 

network – check device/wiring

Note: All LEDs illuminate for several seconds after switch on.

22

23

24

25

RX+

28

29

WMB

RX- TX+ TX-

RX

OK

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

1

2

3

230V

19

4

5

10

24V

0V

0V

0V

0V

0V

0V

9

8

6

7

1

2

3

tX

(yellow)

RX

(yellow)

O

I

Draft

Содержание IQ41 Series

Страница 1: ...Applet Manual TE201298 IQTool Addresser Applet Manual TE201299 IQ4 Configuration Manual TE201263 Note PDF copies are included with SET installation in the following folder C Trend Control Systems Docu...

Страница 2: ...Re continued Serial Number n q 4 e y e c p 4 1 2 3 4 5 Q411B_V53440388 O S Q411B_V53440388 n q 4 e y e c p 4 1 2 3 4 5 00 10 70 0D 1E 92 MAC Addr IQ411 1010U5000 Part No LAN 4 MAC Addr IP Addr LAN Loc...

Страница 3: ...d 22 23 24 25 RX 28 29 WMB RX TX TX RX OK 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1 2 3 230V 19 4 5 10 24V 0V 0V 0V 0V 0V 0V 9 8 6 7 1 2 3 Watchdog red Power green 11 Check ethernet LeDs if Ethernet is...

Страница 4: ...addressing the unit automatical obtains its IP addressing details IP address subnet mask default router WINS server and DNS server from the network s DHCP Dynamic Host Configuration Protocol server I...

Страница 5: ...run the IQTool Addresser Applet and click to run the Discovery Wizard Select either Automatic Discovery recommended or Manual Discovery If Automatic Discovery was selected you should also select Dupl...

Страница 6: ...IQTool Monitor Applet Manual TE201298 20 Set up Additional Trend Addressing if required IQTool Monitor Applet Manual TE201298 If the IQ41x is to provide a network connection for supervisors and tools...

Страница 7: ...nd switch off all other devices on the network If still OFF check network cabling for short circuits with a multimeter NOT Megger If ON switch on other devices until faulty device found i e OK LED goe...

Страница 8: ...9k6 Note SET will set up the controller s date and time to that of the PC during download However they may be set up from a controller configured as timemaster Configure the strategy using SET and te...

Страница 9: ...supervisors tools and displays as described in Connect to IQ4 on page 10 Connection of PCs displays etc can be made directly to controller via the RS232 Local supervisor Port USB Local Engineering Por...

Страница 10: ...o IQ4 can be made directly via the RS232 Local Supervisor Port USB Local Engineering Port or Ethernet Port Connection can also be made over a network Ethernet Connection use Notes IPTool SET Web Brows...

Страница 11: ...vice on the same Ethernet Trend network Note If connecting with IP Tool the PC should be on the same Ethernet segment as the IQ4 Note To make a connection with a web browser use IQ4 s IP address or ho...

Страница 12: ...r steps 1 to 5 of the Installation Configuring section 5 DISPoSAL WEEE Directive At the end of their useful life the packaging and product should be disposed of by a suitable recycling centre Do not d...

Отзывы: