background image

12 

IQ41x Installation Instructions - Confi guring TG201251 Issue 5, 22-Aug-2014

IQ41x

InstallationInstructions-Configuring

Please send any comments about this or any other Trend technical publication to [email protected]

© 

2014 Honeywell Technologies Sàrl, ECC Division. All rights reserved. Manufactured for and on behalf of the Environmental and Combustion Controls 

Division of Honeywell Technologies Sàrl, Z.A. La Pièce, 16, 1180 Rolle, Switzerland by its Authorized Representative, Trend Control Systems Limited.

 Trend Control Systems Limited reserves the right to revise this publication from time to time and make changes to the content hereof without obligation 

to notify any person of such revisions or changes.

trendControlSystemsLimited

Albery House, Springfi eld Road, Horsham, West Sussex, RH12 2PQ, UK. Tel:+44 (0)1403 211888 Fax:+44 (0)1403 241608 www.trendcontrols.com

trendControlSystemsuSA

6670  185th  Avenue  NE,  Redmond,  Washington  98052,  USA.  Tel:(425)  869-3900  Fax:(425)  869-8445  www.trend-americas.com

3

Reset Controller

4

Re-configureController

 2

CloseRotatingCovers

1

open Panel

4

ReSettoDeFAuLtS

Switch Off, Isolate I/O, Open Panel, Open Rotating Covers, 

and Disconnect I/O as per steps (1) to (5) of the ‘Installation 

- Confi guring’ section.

5

DISPoSAL

WEEE Directive:

At  the  end  of  their  useful  life  the  packaging  and 

product  should  be  disposed  of  by  a  suitable 

recycling centre.

Do not dispose of with normal household waste.

Do not burn.

Re-confi gure controller as described in these instructions.

Press and hold down the service button,

 

the service button 

LED  will  fl ash

While  continuing  to  hold  down  the  button, 

switch on the controller. Ensure the button remains pressed 

for 2 to 5 s after power is switched on. Do not switch off the 

controller for at least 1 minute.

O

I

2 to 5 s

22

23

24

25

RX+

28

29

WMB

RX- TX+ TX-

RX

OK

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

1

2

3

230V

19

4

5

10

24V

0V

0V

0V

0V

0V

0V

9

8

6

7

1

2

3

Press

22

23

24

25

RX+

28

29

WMB

RX- TX+ TX-

RX

OK

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

1

2

3

230V

19

4

5

10

24V

0V

0V

0V

0V

0V

0V

9

8

6

7

1

2

3

Release

WARNING FoR /230 versions: 

Hazardous 

voltages  exist  in  this  area  when  the  unit  is 

powered. This operation should only be performed 

after taking suitable precautions

The strategy, user modules (passwords, PINs etc), alarm logs, 

and plots are cleared down and the following parameters set 

to defaults:

Lan number,

outstation address

IP addressing mode

IP address,

subnet mask

UDP port

identifi er

Router 1

remote Trend devices,

Virtual vCNC). 

Backdrop fi les are unchanged and time and date left at their 

current settings.

Draft

Содержание IQ41 Series

Страница 1: ...Applet Manual TE201298 IQTool Addresser Applet Manual TE201299 IQ4 Configuration Manual TE201263 Note PDF copies are included with SET installation in the following folder C Trend Control Systems Docu...

Страница 2: ...Re continued Serial Number n q 4 e y e c p 4 1 2 3 4 5 Q411B_V53440388 O S Q411B_V53440388 n q 4 e y e c p 4 1 2 3 4 5 00 10 70 0D 1E 92 MAC Addr IQ411 1010U5000 Part No LAN 4 MAC Addr IP Addr LAN Loc...

Страница 3: ...d 22 23 24 25 RX 28 29 WMB RX TX TX RX OK 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1 2 3 230V 19 4 5 10 24V 0V 0V 0V 0V 0V 0V 9 8 6 7 1 2 3 Watchdog red Power green 11 Check ethernet LeDs if Ethernet is...

Страница 4: ...addressing the unit automatical obtains its IP addressing details IP address subnet mask default router WINS server and DNS server from the network s DHCP Dynamic Host Configuration Protocol server I...

Страница 5: ...run the IQTool Addresser Applet and click to run the Discovery Wizard Select either Automatic Discovery recommended or Manual Discovery If Automatic Discovery was selected you should also select Dupl...

Страница 6: ...IQTool Monitor Applet Manual TE201298 20 Set up Additional Trend Addressing if required IQTool Monitor Applet Manual TE201298 If the IQ41x is to provide a network connection for supervisors and tools...

Страница 7: ...nd switch off all other devices on the network If still OFF check network cabling for short circuits with a multimeter NOT Megger If ON switch on other devices until faulty device found i e OK LED goe...

Страница 8: ...9k6 Note SET will set up the controller s date and time to that of the PC during download However they may be set up from a controller configured as timemaster Configure the strategy using SET and te...

Страница 9: ...supervisors tools and displays as described in Connect to IQ4 on page 10 Connection of PCs displays etc can be made directly to controller via the RS232 Local supervisor Port USB Local Engineering Por...

Страница 10: ...o IQ4 can be made directly via the RS232 Local Supervisor Port USB Local Engineering Port or Ethernet Port Connection can also be made over a network Ethernet Connection use Notes IPTool SET Web Brows...

Страница 11: ...vice on the same Ethernet Trend network Note If connecting with IP Tool the PC should be on the same Ethernet segment as the IQ4 Note To make a connection with a web browser use IQ4 s IP address or ho...

Страница 12: ...r steps 1 to 5 of the Installation Configuring section 5 DISPoSAL WEEE Directive At the end of their useful life the packaging and product should be disposed of by a suitable recycling centre Do not d...

Отзывы: