4 8
Optional Equipment
(for qualified installers only)
Travis Industries
4 0 2 0 8 1 2
9 3 5 0 8 1 1 0
4
Remove the pilot orifice following the instructions below. Replace with the propane pilot orifice
Lift the pilot hood
off the pilot
assembly.
5/32" Hex
Use a hex wrench to
unscrew the orifice.
Remove the orifice and replace with the LP orifice. Screw the
orifice all the way in and replace the pilot hood.
LP (Propane) Orifice
Orifice Identification:
NG (Natural Gas) Orifice
35
62
35
a
b
c
NOTE: when re-attaching,
this pin lines up with the
notch in the pilot hood.
5
Install the logs and embers.
6
Remove the regulator from the front of the gas control valve. Replace with the propane regulator,
using the new gasket and screws included with the regulator. NOTE: Leak test this area after
the heater is installed, gas is connected, and the main burner is lit.
These screws hold the
regulator in place.
NOTE: use the new
screws included with
the regulator.
Phillips
Screwdriver
PILOT ADJ
T
O
L
PI
ON
OFF
VENT
HI
LO
VENT
HI
LO
Align the regulator
gasket so it is flat
and the two tabs fit
through the two
holes on the
gasket.
Regulator Gasket
NOTE: use the new gasket
included with the regulator.
LP (propane) regulators have a
11.0 2.7 stamped here.
NOTE: These holes strip
easily. Use a hand
screwdriver and tighten
each screw evenly.
9
Install the logs and embers.
1 0 Replace glass and face.