Horizontal Terminations with 1 Vertical Elbow (Top Vent Configuration)
The termination must fall within the shaded area shown in the chart. Use the indicated restrictor position.
NOTE:
• One horizontal elbow (45° or 90°) is allowed. The
horizontal vent length is calculated by adding the length
before and after the elbow (H1 + H2 = horizontal vent
length).
• Horizontal sections require a 1/4" rise every 12" of travel.
• The maximum vertical height is 20'.
• The maximum horizontal length is 24'.