Finalizing the Installation
(for qualified installers only)
© Travis Industries
4100519
100-01197_001
6
The gas control valve has a propane conversion shaft that alters the outlet pressure. Remove
the
aluminum
cap over the propane conversion shaft and twist the small knob so the line points to
“LP” (see Figure 31).
Pilot Adj.
Inlet
Outlet
NATURAL TO PROPANE
CONVERSION SHAFT
(UNDER RUBBER CAP)
LP
NAT
NAT
LP
Main
Pilot
Side View
NG
(Natural Gas)
LP
(Propane)
Conversion Shaft
(Note how it is in a lower
position when switched to LP)
Figure 31
7
Remove the NG rate screw and replace it with the LP rate screw included in the owner’s pack
(see Figure 32). Take care to not damage the rubber o-ring on the rate screw when installing.
Pilot Adj.
Inlet
Outlet
RATE SCREW (BRASS)
LP
NAT
NA T
LP
Main
Pilot
LP
(Propane)
NG
(Natural Gas)
Rate Screws
Figure 32
8
Replace the burner tray, burner assembly, and grate. Install the logs and embers and replace
the glass.
9
Make the gas line connection, bleed the gas line (if applicable), start the heater and thoroughly
leak-test all gas connections and the gas control valve (see page 16 for details). Check the
pilot and adjust if necessary.