Installation
(for qualified installers only)
31
© Travis Industries
4100519
100-01197_001
Facing Requirements
•
Attach the included fiber board (or other non-combustible) to the fireplace and framing (see
Figure 21 below). This non-combustible facing must extend from the base of the fireplace to
the header and to the framing members on both sides.
Use screws to attach the included non-
combustible fiber board to the fireplace
and framing as shown.
WARNING: Do not use adhesive to
secure the cement board or facing. The
high temperatures of the fireplace may
cause adhesives to emit odors. Use
mastic or thin set (or other non-
combustible, non-odorous adherent) to
attach the facing to the cement board.
Adhesive
Drywall
Flanges are provided on the fireplace
for the screws to attach to.
Fiber Board (or other non-combustible) is
required from the glass frame edge to the
side and top framing.
AAAAA
AAAAA
AAAAA
AAAAA
AAAAA
AAAAA
AAAAA
AAAAA
AAAAA
AAAAA
Fiber
Board
Figure 21