2 6
Finalizing the Installation
(for qualified installers only)
Travis Industries
9 3 5 0 8 1 3 4
4 0 3 0 6 2 4
!
We recommend you purge the gas line at this time (with the glass removed). This allows gas to be
detected once it enters the firebox, ensuring gas does not build up.
3
Turn on the gas to the fireplace. Turn on gas to the fireplace. Leak test all gas joints prior to starting
the appliance. Start the pilot (see page 29). Start the main burner. Leak test all gas joints again.
4
Replace the glass frame.
5
Check the pilot flame to make sure it looks like the illustration below. Adjust the pilot flame if
necessary.
Standard
Screwdriver
The pilot flame must contact the thermocouple and
thermopile (see the illustration below). Adjust the pilot up or
down as necessary.
To adjust the pilot flame, turn this screw (NOTE: if totally
unscrewed gas will come out of this port). Clockwise
lowers the flame while counter-clockwise raises it.
6
Let the fireplace burn for fifteen minutes. Observe the flame and compare to the illustrations below. If
the flame is not correct, shut off the appliance and contact your local service provider.
Correct
Flames should be blue at the
base, yellow-orange on the top.
If the flames are over 14" (360 mm) tall
or sooty on the ends, contact your local
service provider.
Not Enough Air
If the flames are all blue and
short, contact your local service
provider.
Too Much Air
Содержание 35 CB Australian