Optional Equipment
(for qualified installers only)
Travis Industries
9 3 5 0 8 1 3 4
4 0 3 0 6 2 4
Thermostat (Part # 99300650)
!
Do not connect 240 VAC to the gas control valve or wiring of this unit.
1
Attach the thermostat wire to the on/off switch and route it through the grommet located on either side
of the fireplace (see the illustration below). Pull through all the slack.
Remove the jumper wire on
the back of the on/off switch
and discard.
Back of
on/off switch
Red & brown wires
leading to the gas
control valve.
a
b
Connect the thermostat wires to back
of the on/off switch (orientation does
not matter).
c
Route the thermostat wire out the grommet-lined
thermostat hole (located behind the hole for the
gas line on either side).
Jumper Wire
(green wire)
Thermostat Wire
Hole (with grommet)
Gas Line
2
Determine a location for the thermostat that is within range of the 50' (15 M) length of thermostat wire.
It should be centralized in the room and away from the fireplace. The wire may be routed externally on
the wall or behind the wall (preferred).
3
Cut the thermostat wire so there is approximately 6" (152 mm) of slack (NOTE: Do not splice
thermostat wires together–this leads to too much electrical resistance). Follow the directions below to
install the thermostat.
50 60 70 80 90
50 60 70 80 90
Robertshaw
Run the thermostat wires
through the wall (cut off excess
wire, leaving 6” (150 mm) of
slack).
Pull the cover off the thermostat
Expose 1/2” (10 mm) of
wire and attach to these
two posts.
Standard
Screwdriver
Attach the thermostat to
the wall through these
two holes.
a
b
c
d
Re-attach the cover
removed in step “a”.