Finalizing the Installation
(for qualified installers only)
2 7
Travis Industries
9 3 5 0 8 1 3 4
4 0 3 0 6 2 4
!
If the vent configuration is installed incorrectly the vent may cause the flames inside the fireplace to lift
or "ghost" – a dangerous situation. Inspect the flames after installation to insure proper performance.
If the vent configuration is correct, yet the flames are lifting or ghosting, shut off gas to the fireplace
and contact the dealer for information on remedying the problem.
!
This fireplace has been tested at altitudes up to 8,000 feet (2,440 M). In this testing we have found
that the fireplace, with its standard orifice, burns correctly with just an air shutter adjustment. If local
codes require resizing the orifice, in the U.S.A. refer to ANSI 223.1, Appendix P, in Canada B-149.1
or B-149.2
The flames should burn right off
the top of the burner ports.
If the flames are lifting, yet the
vent configuration is correct,
contact your dealer.
Burner Pan
Burner Ports
(holes)
If the flames are ghosting, yet the
vent configuration is correct,
contact your dealer.
7
The flames should burn off of each burner hole. If the heater does not work correctly, contact your
dealer for a remedy.
8
Give this manual to the home owner and fully explain the operation of this heater.