background image

Maintenance

In order to get the best performance, please follow the  

instructions below.

Put in a dry place and avoid the sunshine

Avoid intense shaking

and collisions

Using wet cloths to remove dirt

Avoid touching water,

clean it with a dry cloth in case.

Avoid dusty and unstable

temperature environment

Avoid washing the cuff

Only a physician can tell your normal BP range.

Please contact a physician if your measuring 

result falls out of the range. Please note that only 

a physician can tell whether your blood pressure 

value has reached a dangerous point.

What are systolic pressure and diastolic pressure? 

press

artery

vein

blood discharging

Systolic

relax

blood entering

Diastolic  

When ventricles contract and pump blood out 

of the heart, the blood pressure reaches its 

maximum value in the cycle, which is called 

systolic pressure. When the ventricles relax, 

the blood pressure reaches its minimum value 

in the cycle, which is called diastolic pressure.

What is the standard blood pressure classification?

The blood pressure classification published 

by World Health Organization (WHO) and 

International Society of Hypertension (ISH) 

in 1999 is as follows:

Irregular Heartbeat Detector

CAUTION

The appearance of the IHB icon indicates that a pulse irregularity consistent with an 

irregular heart-beat was detected during measurement. Usually this is NOT a cause for 

concern. However, if the symbol appears often, we recommend you seek medical advice. 

Please note that the device does not replace a cardiac examination, but serves to detect 

pulse irregularities at an early stage.

CAUTION

SYS

DIA

<120

<80

120-129

80-84

130-139

85-89

140-159

90-99

160-179

100-109

≥180

≥110

Level

Blood

Pressure (mm Hg) 

Optimal

Normal

High-normal

Mild

Moderate

Severe

An irregular heartbeat is detected when a heartbeat rhythm varies while the unit is 

measuring the systolic and diastolic blood pressure.During each measurement, 

this equipment records the heartbeat intervals and works out the standard deviation. 

If the calculated value is larger than or equal to 25%,the irregular heartbeat symbol 

appears on the symbol when the measurement results are displayed.

15

14

ABOUT BLOOD PRESSURE

INFORMATION FOR USER

Содержание TMB-1018-A

Страница 1: ...r selecting TRANSTEK Blood Pressure Monitor TMB 1018 A Please keep this manual well in order to reference in future Arm Type Version 1 0 EC REP Guangdong Transtek Medical Electronics Co Ltd Zone A No...

Страница 2: ...ON FOR USER 13 Tips for measurement Maintenances ABOUT BLOOD PRESSURE 15 What are systolic pressure and diastolic pressure What is the standard blood pressure classification Why does my blood pressure...

Страница 3: ...deflate Should the cuff not deflate when pressures exceeds 40 kPa 300 mmHg detach the cuff from the arm and press the START STOP button to stop inflation The equipment is not AP APG equipment and not...

Страница 4: ...ure 1kPa 7 5mmHg Low battery Batteries are low and need to be replaced Shocking reminding Shocking will result in inaccurate Average The average of blood pressure Recalling The records will be showed...

Страница 5: ...ery cover Install the batteries by matching the correct polarity as shown Replace the cover 1 Battery powered mode 6VDC 4 AAA batteries 2 AC adaptor powered mode 6V 1A Please only use the recommended...

Страница 6: ...he cuff should be snug but not too tight You should be able to insert one finger between the cuff and your arm 3 Sit comfortably with your tested arm resting on a flat surface 2 3cm 4 Repeat steps 2 a...

Страница 7: ...st CAUTION The order of the record date time will display alternately 1 When the monitor is off press the START STOP to turn on the monitor and it will finish the whole measurement Adjust the zero LCD...

Страница 8: ...3 If you don t want to delete the records press START STOP to escape If you did not get the correct measurement you can delete all results by following steps below Delete the Records 4 If there is no...

Страница 9: ...classification The blood pressure classification published by World Health Organization WHO and International Society of Hypertension ISH in 1999 is as follows Irregular Heartbeat Detector CAUTION Th...

Страница 10: ...fer to the warranty for contact information and return instructions E21 shows The treatment of the measurement failed Relax for a moment and then measure again AC adaptor is inserted incorrectly Inser...

Страница 11: ...00 240V 50 60Hz 400mA Output 6V 1A Type UE08WCP 060100SPA Conforms to UL certificate Contact Information For more information about our products please visit www transtek cn you can get customer servi...

Страница 12: ...ablishments and those directly connected to the public low voltage power supply network that supplies buildings used for domestic purposes Risk management Labeling User manual General Requirements for...

Страница 13: ...G Guidance and manufacturer s declaration electromagnetic immunity IMMUNITY test Not applicable 3 V m Compliance level IEC 60601 TEST LEVEL Conducted RF IEC 61000 4 6 Radiated RF IEC 61000 4 3 3 V m 8...

Страница 14: ...the device as recommended below according to the maximum output power of the communications equipment Rated maximum output power of transmitter W Separation distance according to frequency of transmit...

Отзывы: