Power supply

Battery powered mode: 

6VDC 4*AAA batteries

AC adaptor powered mode:

6V     1A

(Please only use the recommended AC

adaptor model) (Not Included).

Display mode

Digital  LCD  V.A.140mm*36mm

Measurement mode

Oscillographic testing mode

Measurement range

Accuracy

Normal working condition

Storage & transportation

condition

Measurement perimeter

of the upper arm

About 22cm~32cm

Net Weight

Approx.270g(Excluding the dry cells)

External dimensions

Attachment

Approx.180mm*100mm*40mm

4*AAA batteries,user manual  

Mode of operation

Continuous operation

Degree of protection

Type BF applied part

Protection against 

ingress of water

IP21

WARNING: No modification of this equipment is allowed.

Software Version

V01

Authorized Component

1

.

Please use the TRANSTEK 

authorized adapter

(Not Included).

Adapter

Input:

100~240V

50~60Hz,400mA

Output:

6V      1A

Type:

UE08WCP-060100SPA

( Conforms to UL certificate )

Contact Information

For more information about our products, please visit www.transtek.cn.you 

can get customer service, usual problems and customer download, transtek will 

serve you anytime.

Temperature:5

 to 40

 

Relative humidity ≤85%RH

Atmospheric pressure: 86kPa to 106kPa

Temperature:-20

-60

Relative Humidity: 10%RH-93%RH

Atmospheric Pressure: 50kPa-106 kPa

Rated cuff pressure: 

0kPa - 40kPa (0mmHg~300mmHg)

Measurement pressure: 5.3kPa-30.7kPa

(40mmHg-230mmHg)

pulse value: (40-199) beat/minute

Pressure:

5

-40

within±0.4kPa(3mmHg) 

pulse value:±5%

Authorized European Representative:

Manufactured by:

Company:

Address:

Company:

MDSS - Medical Device Safety Service GmbH

Address:

Schiffgraben 41, 30175 Hannover, Germany

Guangdong Transtek Medical Electronics Co., Ltd.

Zone A, No.105 ,Dongli Road, Torch Development District, 

Zhongshan,528437,Guangdong,China  

Guangdong Transtek Medical Electronics Co., Ltd.

18

19

AUTHORIZED COMPONENT

SPECIFICATIONS

Содержание TMB-1018-A

Страница 1: ...r selecting TRANSTEK Blood Pressure Monitor TMB 1018 A Please keep this manual well in order to reference in future Arm Type Version 1 0 EC REP Guangdong Transtek Medical Electronics Co Ltd Zone A No...

Страница 2: ...ON FOR USER 13 Tips for measurement Maintenances ABOUT BLOOD PRESSURE 15 What are systolic pressure and diastolic pressure What is the standard blood pressure classification Why does my blood pressure...

Страница 3: ...deflate Should the cuff not deflate when pressures exceeds 40 kPa 300 mmHg detach the cuff from the arm and press the START STOP button to stop inflation The equipment is not AP APG equipment and not...

Страница 4: ...ure 1kPa 7 5mmHg Low battery Batteries are low and need to be replaced Shocking reminding Shocking will result in inaccurate Average The average of blood pressure Recalling The records will be showed...

Страница 5: ...ery cover Install the batteries by matching the correct polarity as shown Replace the cover 1 Battery powered mode 6VDC 4 AAA batteries 2 AC adaptor powered mode 6V 1A Please only use the recommended...

Страница 6: ...he cuff should be snug but not too tight You should be able to insert one finger between the cuff and your arm 3 Sit comfortably with your tested arm resting on a flat surface 2 3cm 4 Repeat steps 2 a...

Страница 7: ...st CAUTION The order of the record date time will display alternately 1 When the monitor is off press the START STOP to turn on the monitor and it will finish the whole measurement Adjust the zero LCD...

Страница 8: ...3 If you don t want to delete the records press START STOP to escape If you did not get the correct measurement you can delete all results by following steps below Delete the Records 4 If there is no...

Страница 9: ...classification The blood pressure classification published by World Health Organization WHO and International Society of Hypertension ISH in 1999 is as follows Irregular Heartbeat Detector CAUTION Th...

Страница 10: ...fer to the warranty for contact information and return instructions E21 shows The treatment of the measurement failed Relax for a moment and then measure again AC adaptor is inserted incorrectly Inser...

Страница 11: ...00 240V 50 60Hz 400mA Output 6V 1A Type UE08WCP 060100SPA Conforms to UL certificate Contact Information For more information about our products please visit www transtek cn you can get customer servi...

Страница 12: ...ablishments and those directly connected to the public low voltage power supply network that supplies buildings used for domestic purposes Risk management Labeling User manual General Requirements for...

Страница 13: ...G Guidance and manufacturer s declaration electromagnetic immunity IMMUNITY test Not applicable 3 V m Compliance level IEC 60601 TEST LEVEL Conducted RF IEC 61000 4 6 Radiated RF IEC 61000 4 3 3 V m 8...

Страница 14: ...the device as recommended below according to the maximum output power of the communications equipment Rated maximum output power of transmitter W Separation distance according to frequency of transmit...

Отзывы: