Setting Date, Time and Measurement Unit

  It is important to set the clock before using your blood pressure 

monitor, so that a time stamp can be assigned to each record that 

is stored in the memory. (The setting range of the year :2000—2050,

time:24 H)

1

.When the monitor is off, 

hold pressing “SET” 

for 3 seconds to enter 

the mode for year 

setting.

2

.The [YEAR] blinks,

press the “MEM” 

button to change

the numeral of 

the year. 

3

.When you get the 

right year, press 

“SET” to set down 

and turn to next step. 

The Choice of Power Supply

In order to get the best effect and protect your monitor,please use the right 

battery and special power adapter which complies with CE safety standard.

.

Slide off the battery cover.

.

Install the batteries by matching 

the correct polarity, as shown.

.

Replace the cover.

1

.Battery powered mode:

    6VDC 4*AAA batteries

2

.AC adaptor powered mode:

   6V       1A

(Please only use the recommended  AC 

adaptor model) (Not Included).

Please unplug the adaptor to depart from 
the using utility power.

Installing and Replacing the Batteries

CAUTION

Remove batteries if the device is not likely to be used for some time.
The old batteries are harmful to the environment, do not dispose with other daily trash.
Remove the old batteries from the device and follow your local recycling guidelines.

CAUTION

Replace the batteries whenever the below happen

The                     shows
The display dims

The display does not light up

AC adaptor

Do not dispose of batteries in fire. Batteries may explode or leak.

START   STOP

T

E

S

M

E

M

START   STOP

T

E

S

M

E

M

START   STOP

T

E

S

M

E

M

7

6

BEFORE YOU START

BEFORE YOU START

Содержание TMB-1018-A

Страница 1: ...r selecting TRANSTEK Blood Pressure Monitor TMB 1018 A Please keep this manual well in order to reference in future Arm Type Version 1 0 EC REP Guangdong Transtek Medical Electronics Co Ltd Zone A No...

Страница 2: ...ON FOR USER 13 Tips for measurement Maintenances ABOUT BLOOD PRESSURE 15 What are systolic pressure and diastolic pressure What is the standard blood pressure classification Why does my blood pressure...

Страница 3: ...deflate Should the cuff not deflate when pressures exceeds 40 kPa 300 mmHg detach the cuff from the arm and press the START STOP button to stop inflation The equipment is not AP APG equipment and not...

Страница 4: ...ure 1kPa 7 5mmHg Low battery Batteries are low and need to be replaced Shocking reminding Shocking will result in inaccurate Average The average of blood pressure Recalling The records will be showed...

Страница 5: ...ery cover Install the batteries by matching the correct polarity as shown Replace the cover 1 Battery powered mode 6VDC 4 AAA batteries 2 AC adaptor powered mode 6V 1A Please only use the recommended...

Страница 6: ...he cuff should be snug but not too tight You should be able to insert one finger between the cuff and your arm 3 Sit comfortably with your tested arm resting on a flat surface 2 3cm 4 Repeat steps 2 a...

Страница 7: ...st CAUTION The order of the record date time will display alternately 1 When the monitor is off press the START STOP to turn on the monitor and it will finish the whole measurement Adjust the zero LCD...

Страница 8: ...3 If you don t want to delete the records press START STOP to escape If you did not get the correct measurement you can delete all results by following steps below Delete the Records 4 If there is no...

Страница 9: ...classification The blood pressure classification published by World Health Organization WHO and International Society of Hypertension ISH in 1999 is as follows Irregular Heartbeat Detector CAUTION Th...

Страница 10: ...fer to the warranty for contact information and return instructions E21 shows The treatment of the measurement failed Relax for a moment and then measure again AC adaptor is inserted incorrectly Inser...

Страница 11: ...00 240V 50 60Hz 400mA Output 6V 1A Type UE08WCP 060100SPA Conforms to UL certificate Contact Information For more information about our products please visit www transtek cn you can get customer servi...

Страница 12: ...ablishments and those directly connected to the public low voltage power supply network that supplies buildings used for domestic purposes Risk management Labeling User manual General Requirements for...

Страница 13: ...G Guidance and manufacturer s declaration electromagnetic immunity IMMUNITY test Not applicable 3 V m Compliance level IEC 60601 TEST LEVEL Conducted RF IEC 61000 4 6 Radiated RF IEC 61000 4 3 3 V m 8...

Страница 14: ...the device as recommended below according to the maximum output power of the communications equipment Rated maximum output power of transmitter W Separation distance according to frequency of transmit...

Отзывы: