background image

Transition Networks 

 

                                            SISGM1040-244 

 

24-Hour Technical Support: 1-800-260-1312                            International: 00-1-952-941-7600 

 

IGMP Commands Set ..................................................... 43

 

Mac / Filter Table Commands Set ................................... 44

 

SNMP Commands Set .................................................... 45

 

Port Mirroring Commands Set ......................................... 47

 

802.1x Commands Set.................................................... 48

 

TFTP Commands Set...................................................... 50

 

SystemLog, SMTP and Event Commands Set ................ 51

 

SNTP Commands Set ..................................................... 53

 

X-ring Commands Set ..................................................... 54

 

Web-Based Management ................................55

 

About Web-based Management ............................ 55

 

Preparing for Web Management ............................ 55

 

System Login ......................................................... 56

 

Main interface......................................................... 57

 

System Information ................................................ 58

 

IP Configuration ..................................................... 58

 

DHCP Server – System configuration.................... 59

 

DHCP Client – System Configuration .................... 60

 

DHCP Server - Port and IP Bindings ..................... 61

 

Содержание SISGM1040-244

Страница 1: ...4 10 100 1000T 4 100 1000 Mini GBIC w X Ring L2 Managed Industrial Switch User Manual SISGM1040 244 Version 1 00 February 8 2010 ...

Страница 2: ... 7600 Content Overview 1 Introduction 1 Features 4 Technical Specification 6 Packing List 9 Safety Precaution 9 Hardware Description 10 Front Panel 10 Top View 11 Wiring the Power Inputs 11 LED Indicators 12 Ports 13 Cabling 14 Mounting Installation 19 DIN Rail Mounting 19 Wall Mount Plate Mounting 20 ...

Страница 3: ...Coupling Ring Application 23 Dual Homing Application 24 Console Management 25 Connecting to the Console Port 25 Pin Assignment 26 Login in the Console Interface 26 CLI Management 28 Commands Level 29 Commands Set List 30 System Commands Set 30 Port Commands Set 33 Trunk Commands Set 36 DMI Commands Set 38 VLAN Commands Set 38 Spanning Tree Commands Set 40 QOS Commands Set 43 ...

Страница 4: ... Set 47 802 1x Commands Set 48 TFTP Commands Set 50 SystemLog SMTP and Event Commands Set 51 SNTP Commands Set 53 X ring Commands Set 54 Web Based Management 55 About Web based Management 55 Preparing for Web Management 55 System Login 56 Main interface 57 System Information 58 IP Configuration 58 DHCP Server System configuration 59 DHCP Client System Configuration 60 DHCP Server Port and IP Bindi...

Страница 5: ...62 System Event Log Syslog Configuration 63 System Event Log SMTP Configuration 64 System Event Log Event Configuration 66 Fault Relay Alarm 68 SNTP Configuration 68 IP Security 71 User Authentication 72 Port Statistics 73 Port Control 74 Port Trunk 75 Aggregator setting 75 Aggregator Information 76 State Activity 77 Port Mirroring 78 Rate Limiting 79 DMI Digital Monitoring Interface 80 ...

Страница 6: ...pid Spanning Tree 88 RSTP System Configuration 88 RSTP Port Configuration 90 SNMP Configuration 91 System Configuration 92 Trap Configuration 93 SNMPV3 Configuration 94 QoS Configuration 97 QoS Policy and Priority Type 97 Port Base Priority 98 COS Configuration 99 TOS Configuration 99 IGMP Configuration 99 X Ring 101 Security 103 802 1X Radius Configuration 103 MAC Address Table 106 ...

Страница 7: ...Transition Networks SISGM1040 244 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Factory Default 109 Save Configuration 109 System Reboot 109 Troubles shooting 110 ...

Страница 8: ...wide band paths in short distance 100 m while the SFP slots can be used for the application of wideband uploading and long distance transmissions to fit the field request flexibility Also the long MTBF Mean Time Between Failures ensures that the 4 10 100 1000T 4 SFP Managed Industrial Switch will continue to operate until a Gigabit network infrastructure has been established without requiring any ...

Страница 9: ... speeds 10 100 1000 Mbps The RJ 45 interface can also be auto detected so MDI or MDI X is automatically selected and a crossover cable is not required All Ethernet ports have memory buffers that support the store and forward mechanism This assures that data is properly transmitted Dual Power Input The redundant power input design of 4 10 100 1000T 4 SFP Managed Industrial Switch is with power rese...

Страница 10: ...SFP Managed Industrial Switch more suitable for harsh environments Wide Operating Temperature The operating temperature of the 4 10 100 1000T 4 SFP Managed Industrial Switch is between 40 75o C With such a wide range you can use the 4 10 100 1000T 4 SFP Managed Industrial Switch in some of the harshest industrial environments that exist Easy Troubleshooting LED indicators make troubleshooting quic...

Страница 11: ...SD protection Power Supply Wide range Redundant Power Design Power Polarity Reverse Protect Overload Current Protection Case Installation IP 30 Protection DIN Rail and Wall Mount Design Spanning Tree Support IEEE802 1d Spanning Tree Support IEEE802 1w Rapid Spanning Tree VLAN Port Based VLAN Support 802 1 Q Tag VLAN GVRP X Ring X Ring Dual Homing and Couple Ring Topology Provide redundant backup f...

Страница 12: ... Alert Relay Alarm Output System Events Security Port Security MAC address entries filter IP Security IP address security management to prevent unauthorized intruder Login Security IEEE802 1X RADIUS SNMP Trap Device cold start Power status Authentication failure X Ring topology changed Port Link up Link down IGMP with Query mode for Multi Media Application TFTP Firmware Update and System Configure...

Страница 13: ...RJ 45 4 port 10 100 1000TX 4 x 100 1000 SFP sockets 6 pin removable screw terminal Power Relay LED Indicators Unit Power1 Power2 P Fail R Master Ethernet port Link Active 1000M SFP Link Active Network Management Configuration Web browser Telnet Serial Console Windows Utility TFTP SNMP v1 v2c v3 Port Speed Duplex Configuration VLAN IEEE 802 1Q GVRP Port based VLAN Redundancy X Ring Recovery time 20...

Страница 14: ...tts Power Input 2 x Unregulated 12 48 VDC 24VAC 18 30V Fault Output 1 Relay Output Mechanism Dimensions WxHxD 59 6 x 152 x 105 mm Enclosure IP 30 Metal shell with solid mounting kits Mounting DIN Rail Wall Mount Protection ESD Ethernet 6 000 VDC Surge EFT for power 3 000 VDC Power Reverse Yes Overload current protection Yes Environment Operating Temperature 40 75o C 40 65 non air flow environment ...

Страница 15: ...E EN61000 6 2 CE EN61000 6 4 CE EN61000 4 2 ESD CE EN61000 4 3 RS CE EN61000 4 4 EFT CE EN61000 4 5 Surge CE EN61000 4 6 CS CE EN61000 4 8 Magnetic Field CE EN61000 4 11 Voltage DIP CE EN61000 3 2 Harmonics Current CE EN61000 3 3 Voltage Fluctuation Flickers Free Fall IEC60068 2 32 Shock IEC60068 2 27 Vibration IEC60068 2 6 ...

Страница 16: ...al 00 1 952 941 7600 Packing List 1 x 4 10 100 1000T 4 SFP Managed Industrial Switch 1 x RS232 Cable 1 x User Manual 2 x Wall Mounting Bracket and Screws Safety Precaution Attention IF DC voltage is supplied by an external circuit please use a protection device on the power supply input ...

Страница 17: ...ription In this paragraph we will introduce the Industrial switch s hardware spec port cabling information and wiring installation Front Panel The Front Panel of 4 10 100 1000T 4 SFP Managed Industrial Switch is shown as below Front Panel of 4 10 100 1000T 4 SFP Managed Industrial Switch ...

Страница 18: ... 100 1000T 4 SFP Managed Industrial Switch is equipped one terminal block connector of two DC power inputs Top panel of the 4 10 100 1000T 4 SFP Industrial Switch Wiring the Power Inputs Please follow the steps below to insert the power wire Insert the positive and negative wires into the V and V contacts on the terminal block connector ...

Страница 19: ... of 4 10 100 1000T 4 SFP Industrial Switch each of them has its own specific meaning as tabled below LED Color Description On The industrial switch is the master of the X ring group R Master Green Off The industrial switch is not the master of the X ring group On Power input 1 is active PWR1 Green Off Power input 1 is inactive On Power input 2 is active PWR2 Green Off Power input 2 is inactive On ...

Страница 20: ...X or 1000Base T devices connections Auto MDI MDIX means that you can connect to another switch or workstation without changing straight through or crossover cabling See figures as below for straight through and crossover cable schematic RJ 45 Pin Assignments Pin Number Assignment 1 Tx 2 Tx 3 Rx 6 Rx Note and signs represent the polarity of the wires that make up each wire pair All ports on this in...

Страница 21: ... Schematic Cabling Use the four twisted pair Category 5e or above cabling for RJ 45 port connection The cable between the switch and the link partner switch hub workstation etc must be less than 100 meters 328 ft long As for the small form factor pluggable SFP which is a compact optical transceiver used in optical communications for both telecommunication and data communication applications To con...

Страница 22: ...Transition Networks SISGM1040 244 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Transceiver to the SFP module Transceiver Inserted ...

Страница 23: ... 1 952 941 7600 Second insert the fiber cable of LC connector into the transceiver LC connector to the transceiver To remove the LC connector from the transceiver please follow the steps shown below First press the upper side of the LC connector from the transceiver and pull it out to release ...

Страница 24: ...Transition Networks SISGM1040 244 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Remove LC connector ...

Страница 25: ...ion Networks SISGM1040 244 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Second push down the metal loop and pull the transceiver out by the plastic part Pull out from the SFP module ...

Страница 26: ... Rail is screwed on the industrial switch when out of factory If the DIN Rail is not screwed on the industrial switch please see the following figure to screw the DIN Rail on the switch Follow the below steps to hang the industrial switch Step 1 Use the screws to screw on the DIN Rail on the industrial switch Step 2 To remove the DIN Rail reverse step 1 ...

Страница 27: ...n lightly push the button of DIN Rail into the track 3 Check the DIN Rail is tightly on the track 4 To remove the industrial switch from the track reverse the steps above Wall Mount Plate Mounting Follow the steps as below to mount the industrial switch with wall mount plate 1 Remove the DIN Rail from the industrial switch loose the screws to remove the DIN Rail ...

Страница 28: ...late on the rear panel of the industrial switch 3 Use the screws to screw the wall mount plate on the industrial switch 4 Use the hook holes at the corners of the wall mount plate to hang the industrial switch on the wall 5 To remove the wall mount plate reverse steps above Use screws to screw the wall mount plate on the rear side ...

Страница 29: ... please refer to the Wiring the Power Inputs section The power LED on the Industrial switch will light up Please refer to the LED Indicators section for meaning of LED lights 5 Prepare the twisted pair straight through Category 5e above cable for Ethernet connection and SFP transceiver with LC cable for fiber connection 6 Insert one side of Category 5e or above cables into the Industrial switch Et...

Страница 30: ...tem more reliable The X Ring algorithm is similar to Spanning Tree Protocol STP and Rapid STP RSTP algorithm but its recovery time is less than STP RSTP The figure below is a sample of X Ring application Coupling Ring Application In the network it may have more than one X Ring group Using the coupling ring function can connect each X Ring for the redundant backup It can ensure the transmissions be...

Страница 31: ...n loss from between X Ring group and upper level core switch Assign two ports to be the Dual Homing port that is backup port in the X Ring group The Dual Homing function only works when the X Ring function is active Each X Ring group only has one Dual Homing port Note In dual Homing application architecture the upper level switches need to enable the Rapid Spanning Tree protocol ...

Страница 32: ...gement Connecting to the Console Port The supplied cable which one end is RS 232 connector and the other end is RJ 45 connector Attach the end of RS 232 connector to PC or terminal and the other end of RJ 45 connector to the console port of switch The connected terminal or PC must support the terminal emulation program ...

Страница 33: ... NC 4 Blue 5 5 Blue White NC 6 Green NC 7 Brown White NC 8 Brown Login in the Console Interface When the connection between Switch and PC is ready turn on the PC and run a terminal emulation program or Hyper Terminal and configure its communication parameters to match the following default characteristics of the console port Baud Rate 9600 bps Data Bits 8 Parity none Stop Bit 1 Flow control None ...

Страница 34: ...n parameters After finishing the parameter settings click OK When the blank screen shows up press Enter key to bring out the login prompt Key in the root default value for the both User name and Password use Enter key to switch then press Enter key and the Main Menu of console management appears Please see below figure for login screen ...

Страница 35: ...t 1 800 260 1312 International 00 1 952 941 7600 Console login interface CLI Management The system supports the console management CLI command After you login to the system you will see a command prompt To enter CLI management interface type in enable command ...

Страница 36: ...at the privileged level Use this mode to Perform basic tests Displays system information Privileged EXEC Enter the enable command while in user EXEC mode switch Enter disable to exit The privileged command is advance mode Privileged this mode to Displays advance function status Save configures Global Configuration Enter the configure command while in privileged EXEC mode switch config To exit to p...

Страница 37: ...tio n mode enter exit To exist to privileged EXEC mode or end Use this mode to configure parameters for the switch and Ethernet ports Commands Set List System Commands Set Commands Level Description Example show config E Show switch configuration switch show config show terminal P Show console information switch show terminal write memory P Save user configuration into permanent memory flash rom s...

Страница 38: ...ow IP information of switch switch show ip no ip dhcp G Disable DHCP client function of switch switch config no ip dhcp reload G Halt and perform a cold restart switch config reload default G Restore to default switch config default admin username Username G Changes a login username maximum 10 words switch config admin username xxxxxx admin password Password G Specifies a password maximum 10 words...

Страница 39: ...hernet 2 switch config if dhcpserver ipbinding 192 168 1 1 show dhcpserver configuration P Show configuration of DHCP server switch show dhcpserver configuration show dhcpserver clients P Show client entries of DHCP server switch show dhcpserver clients show dhcpserver ip binding P Show IP Binding information of DHCP server switch show dhcpserver ip binding no dhcpserver G Disable DHCP server func...

Страница 40: ...n switch config interface fastEthernet 2 duplex full half I Use the duplex configuration command to specify the duplex mode of operation for Fast Ethernet switch config interface fastEthernet 2 switch config if duplex full speed 10 100 1000 auto I Use the speed configuration command to specify the speed mode of operation for Fast Ethernet the speed can t be set to 1000 if the port isn t a giga por...

Страница 41: ...icast flooded uni cast bandwidth type broadcast multicast I Set interface ingress limit frame type to accept broadcast and multicast frame switch config interface fastEthernet 2 switch config if bandwidth type broadcast multicast bandwidth type broadcast only I Set interface ingress limit frame type to only accept broadcast frame switch config interface fastEthernet 2 switch config if bandwidth ty...

Страница 42: ...mmand to disable the port switch config interface fastEthernet 2 switch config if state Disable show interface configuration I show interface configuration status switch config interface fastEthernet 2 switch config if show interface configuration show interface status I show interface actual status switch config interface fastEthernet 2 switch config if show interface status show interface accoun...

Страница 43: ...ACP active GroupID 1 4 Port list Member port list This parameter could be a port range ex 1 4 or a port list separate by a comma ex 2 3 6 Workport The amount of work ports this value could not be less than zero or be large than the amount of member ports switch config aggregator group 1 1 4 lacp workp 2 or switch config aggregator group 2 1 4 3 lacp workp 3 aggregator group GroupID Port list nolac...

Страница 44: ...regator P Show the information of trunk group switch show aggregator 1 or switch show aggregator 2 or switch show aggregator 3 no aggregator lacp GroupID G Disable the LACP function of trunk group switch config no aggreator lacp 1 no aggregator group GroupID G Remove a trunk group switch config no aggreator group 2 ...

Страница 45: ...ode switch vlan vlanmode portbase or switch vlan vlanmode 802 1q or switch vlan vlanmode gvrp no vlan V No VLAN Switch vlan no vlan Ported based VLAN configuration vlan port based grpname Group Name grpid GroupID port PortNumbers V Add new port based VALN switch vlan vlan port based grpname test grpid 2 port 2 4 or switch vlan vlan port based grpname test grpid 2 port 2 3 4 show vlan GroupID or sh...

Страница 46: ...untag UntaggedVID tag TaggedVID List V Assign a hybrid link for VLAN by port if the port belong to a trunk group this command can t be applied switch vlan vlan 8021q port 3 hybrid link untag 4 tag 3 6 8 or switch vlan vlan 8021q port 3 hybrid link untag 5 tag 6 8 vlan 8021q trunk PortNumber access link untag UntaggedVID V Assign a access link for VLAN by trunk group switch vlan vlan 8021q trunk 3 ...

Страница 47: ...ble spanning tree switch config spanning tree enable spanning tree priority 0 61440 G Configure spanning tree priority parameter switch config spanning tree priority 32767 spanning tree max age seconds G Use the spanning tree max age global configuration command to change the interval between messages the spanning tree receives from the root switch If a switch does not receive a bridge protocol da...

Страница 48: ...ning tree forward time global configuration command to set the forwarding time for the specified spanning tree instances The forwarding time determines how long each of the listening and learning states last before the port begins forwarding switch config spanning tree forward time 20 stp path cost 1 200000000 I Use the spanning tree cost interface configuration command to set the path cost for Sp...

Страница 49: ... priority 128 stp admin p2p Auto True False I Admin P2P of STP priority on this interface switch config interface fastEthernet 2 switch config if stp admin p2p Auto stp admin edge True False I Admin Edge of STP priority on this interface switch config interface fastEthernet 2 switch config if stp admin edge True stp admin non stp True False I Admin NonSTP of STP priority on this interface switch c...

Страница 50: ...igh G Configure COS Priority switch config qos priority cos 0 middle qos priority tos Priority lowest low mid dle high G Configure TOS Priority switch config qos priority tos 3 high show qos P Displays the information of QoS configuration Switch show qos no qos G Disable QoS function switch config no qos IGMP Commands Set Commands Level Description Example igmp enable G Enable IGMP snooping functi...

Страница 51: ...ch config mac address table filter hwaddr 000012348678 show mac address table P Show all MAC address table switch show mac address table show mac address table static P Show static MAC address table switch show mac address table static show mac address table filter P Show filter MAC address table switch show mac address table filter no mac address table static hwaddr MAC I Remove an entry of MAC a...

Страница 52: ...ig snmp agent mode v1v2cv3 snmp community strings Community right RO RW G Add SNMP community string switch config snmp community strings public right rw snmp server host IP address community Community string trap version v1 v2c G Configure SNMP server host information and community string switch config snmp server host 192 168 1 50 community public trap version v1 remove Switch config no snmp serv...

Страница 53: ...xcluded Included sub oid OID G Configure the mibview table of SNMPV3 agent switch config snmpv3 mibview view V1 type Excluded sub oid 1 3 6 1 show snmp P Show SNMP configuration switch show snmp no snmp community strings Community G Remove the specified community switch config no snmp community strings public no snmp server host Host address G Remove the SNMP server host switch config no snmp serv...

Страница 54: ...bview table of SNMPV3 agent switch config no snmpv3 mibview view V1 type Excluded sub oid 1 3 6 1 Port Mirroring Commands Set Commands Level Description Example monitor rx G Set RX destination port of monitor function switch config monitor rx monitor tx G Set TX destination port of monitor function switch config monitor tx show monitor P Show port monitor information switch show monitor monitor RX...

Страница 55: ...x system radiusip IP address G Use the 802 1x system radius IP global configuration command to change the radius server IP switch config 8021x system radiusip 192 168 1 1 8021x system serverport port ID G Use the 802 1x system server port global configuration command to change the radius server port switch config 8021x system serverport 1815 8021x system accountport port ID G Use the 802 1x system...

Страница 56: ...quietperiod 10 8021x misc txperiod sec G Use the 802 1x misc TX period global configuration command to set the TX period switch config 8021x misc txperiod 5 8021x misc supportimeout sec G Use the 802 1x misc supp timeout global configuration command to set the supplicant timeout switch config 8021x misc supportimeout 20 8021x misc servertimeout sec G Use the 802 1x misc server timeout global confi...

Страница 57: ...net 3 switch config if 8021x portstate accept show 8021x E Displays a summary of the 802 1x properties and also the port sates switch show 8021x no 8021x G Disable 802 1x function switch config no 8021x TFTP Commands Set Commands Level Description Defaults Example backup flash backup_cfg G Save configuration to TFTP and need to specify the IP of TFTP server and the file name of image switch config...

Страница 58: ... system log client server information switch show systemlog no systemlog G Disable systemlog functon switch config no systemlog smtp enable G Enable SMTP function switch config smtp enable smtp serverip IP address G Configure SMTP server IP switch config smtp serverip 192 168 1 5 smtp authentication G Enable SMTP authentication switch config smtp authentication smtp account account G Configure aut...

Страница 59: ... smtp Link UP Link Down Bot h I Set port event for SMTP switch config interface fastethernet 3 switch config if event smtp both show event P Show event selection switch show event no event device cold start G Disable cold start event type switch config no event device cold start no event authentication failure G Disable Authentication failure event typ switch config no event authentication failure...

Страница 60: ...NTP function is inactive this command can t be applied Parameter format yyyymmdd hh mm switch config sntp daylight period 20060101 01 01 20060202 01 01 sntp daylight offset Minute G Set offset of daylight saving time if SNTP function is inactive this command can t be applied switch config sntp daylight offset 3 sntp ip IP G Set SNTP server IP if SNTP function is inactive this command can t be appl...

Страница 61: ...g dualhoming G Enable dual homing switch config ring dualhoming ring ringport 1st Ring Port 2nd Ring Port G Configure 1st 2nd Ring Port switch config ring ringport 7 8 ring couplingport Coupling Port G Configure Coupling Port switch config ring couplingport 1 ring controlport Control Port G Configure Control Port switch config ring controlport 2 ring homingport Dual Homing Port G Configure Dual Ho...

Страница 62: ... such as Microsoft Internet Explorer The Web Based Management supports Internet Explorer 6 0 or later version And it is applied for Java Applets for reducing network bandwidth consumption enhance access speed and present an easy viewing screen Preparing for Web Management Before using the web management install the industrial switch on the network and make sure that any one of the PCs on the netwo...

Страница 63: ...he Internet Explorer on the PC 2 Key in http the IP address of the switch and then Press Enter 3 The login screen will appear right after 4 Key in the user name and password The default user name and password are the same as root 5 Press Enter or OK and then the home screen of the Web based management appears as below Login screen ...

Страница 64: ...Transition Networks SISGM1040 244 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Main interface Main interface ...

Страница 65: ... name of contact person or organization Firmware Version Displays the switch s firmware version Kernel Version Displays the kernel software version MAC Address Displays the unique hardware address assigned by manufacturer default System information interface IP Configuration User can configure the IP Settings and DHCP client function DHCP Client To enable or disable the DHCP client function When D...

Страница 66: ... this column The default IP is 192 168 1 77 Subnet Mask Assign the subnet mask of the IP address If DHCP client function is enabling and then user do not need to assign the subnet mask Gateway Assign the network gateway for the industrial switch The default gateway is 192 168 1 254 DNS1 Assign the primary DNS IP address DNS2 Assign the secondary DNS IP address And then click Apply IP configuration...

Страница 67: ...amic IP assign range is from 192 168 16 100 192 168 16 200 In comparison 192 168 16 200 is the High IP address Subnet Mask the dynamic IP assign range subnet mask Gateway the gateway in your network DNS Domain Name Server IP Address in your network Lease Time sec It is the time period that system will reset the dynamic IP assignment to ensure the dynamic IP will not been occupied for a long time o...

Страница 68: ...vice is connecting to the port and asks for dynamic IP assigning the system will assign the IP address that has been assigned before to the connected device Port and IP Bindings interface TFTP Update Firmware It provides the functions to allow a user to update the switch firmware Before updating make sure you have your TFTP server ready and the firmware image is on the TFTP server 1 TFTP Server IP...

Страница 69: ...tore EEPROM value from TFTP server but you must put the image file on TFTP server first switch will download back flash image 1 TFTP Server IP Address fill in the TFTP server IP 2 Restore File Name fill in the correct restore file name 3 Click Apply Restore Configuration interface TFTP Backup Configuration You can save current EEPROM value from the switch to TFTP server then go to the ...

Страница 70: ...e file name 3 Click Apply Backup Configuration interface System Event Log Syslog Configuration Configuring the system event mode that want to be collected and system log server IP 1 Syslog Client Mode select the system log mode client only server only or both S C 2 System Log Server IP Address assigned the system log server IP 3 Click Reload to refresh the events log 4 Click Clear to clear all cur...

Страница 71: ...rface System Event Log SMTP Configuration You can set up the mail server IP mail account account password and forwarded email account for receiving the event alert 1 Email Alert enable or disable the email alert function 2 SMTP Server IP set up the mail server IP address when Email Alert enabled this function will then be available ...

Страница 72: ...and password for authentication when Email Alert enabled this function will then be available 5 Mail Account set up the email account e g johnadmin to receive the alert It must be an existing email account on the mail server which you had set up in SMTP Server IP Address column 6 Password The email account password 7 Confirm Password reconfirm the password 8 Rcpt e mail Address 1 6 you can assign ...

Страница 73: ... configure Click Apply System event selection 4 selections Device cold start Device warm start SNMP Authentication Failure and X ring topology change Mark the checkbox to select the event When selected events occur the system will issue the logs Device cold start when the device executes cold start action the system will issue a log event Authentication Failure when the SMTP authentication fails t...

Страница 74: ...ort events and per port SMTP events It has 3 selections Link UP Link Down and Link UP Link Down Disable means no event is selected Link UP the system will issue a log message when port connection is up only Link Down the system will issue a log message when port connection is down only Link UP Link Down the system will issue a log message when port connection is up and down ...

Страница 75: ...e SNTP Configuration You can configure the SNTP Simple Network Time Protocol settings The SNTP allows you to synchronize switch clocks in the Internet 1 SNTP Client enable or disable SNTP function to get the time from the SNTP server 2 Daylight Saving Time enable or disable daylight saving time function When daylight saving time is enabling you need to configure the daylight saving time period 3 U...

Страница 76: ...hours 7 am CST Central Standard MDT Mountain Daylight 6 hours 6 am MST Mountain Standard PDT Pacific Daylight 7 hours 5 am PST Pacific Standard ADT Alaskan Daylight 8 hours 4 am ALA Alaskan Standard 9 hours 3 am HAW Hawaiian Standard 10 hours 2 am Nome Alaska 11 hours 1 am CET Central European FWT French Winter MET Middle European MEWT Middle European Winter SWT Swedish Winter 1 hour 1 pm EET East...

Страница 77: ...ndard USSR Zone 8 9 hours 9 pm EAST East Australian Standard GST Guam Standard USSR Zone 9 10 hours 10 pm IDLE International Date Line NZST New Zealand Standard NZT New Zealand 12 hours Midnight 4 SNTP Sever URL set the SNTP server IP address 5 Daylight Saving Period set up the Daylight Saving beginning time and Daylight Saving ending time Both will be different in every year 6 Daylight Saving Off...

Страница 78: ...net Server check boxes will then be available Enable HTTP Server when this check box is checked the IP addresses among Security IP1 IP10 will be allowed to access via HTTP service Enable Telnet Server when checked the IP addresses among Security IP1 IP10 will be allowed to access via telnet service Security IP 1 10 Assign up to 10 specific IP address Only these 10 IP address can access and manage ...

Страница 79: ...0 IP Security interface User Authentication Change web management login user name and password for the management security issue 1 User name Key in the new user name The default is root 2 Password Key in the new password The default is root 3 Confirm password Re type the new password 4 And then click Apply ...

Страница 80: ...itting good packets via this port Tx Bad Packet The counts of transmitting bad packets including undersize less than 64 octets oversize CRC Align errors fragments and jabbers packets via this port Rx Good Packet The counts of receiving good packets via this port Rx Bad Packet The counts of receiving good packets including undersize less than 64 octets oversize CRC error fragments and jabbers via t...

Страница 81: ...rrent port status The port can be set to disable or enable mode If the port setting is disable then will not receive or transmit any packet 3 Negotiation set auto negotiation status of port 4 Speed set the port link speed 5 Duplex set full duplex or half duplex mode of the port 6 Flow Control set flow control function is Symmetric or Asymmetric in Full Duplex mode The default value is Symmetric 7 ...

Страница 82: ...ify the active LACP The switch with the lowest value has the highest priority and is selected as the active LACP 2 Group ID There are three trunk groups to provide configure Choose the Group ID and click Select 3 LACP If enable the group is LACP static trunk group If disable the group is local static trunk group All ports support LACP dynamic trunk group If connecting to the device that also suppo...

Страница 83: ...00 State Activity page 7 Click Apply 8 Use Delete button to delete Trunk Group Select the Group ID and click Delete button Port Trunk Aggregator Setting interface Aggregator Information When you have setup the aggregator setting with LACP disabled you will see the local static trunk group information here ...

Страница 84: ...assive Active The port automatically sends LACP protocol packets Passive The port does not automatically send LACP protocol packets and responds only if it receives LACP protocol packets from the opposite device Note 1 A link having either two active LACP ports or one active port can perform dynamic LACP trunk 2 A link has two passive LACP ports will not perform dynamic LACP trunk because both por...

Страница 85: ... into mirror destination port Destination Port There is only one port can be selected to be destination mirror port for monitoring both RX and TX traffic which come from source port Or use one of two ports for monitoring RX traffic only and the other one for TX traffic only User can connect mirror port to LAN analyzer or Netxray Source Port The ports that user wants to monitor All monitored port t...

Страница 86: ... s bandwidth rate and frame limitation type Ingress Limit Frame type select the frame type that wants to filter The frame types have 4 options for selecting All Broadcast Multicast Flooded Unicast Broadcast Multicast and Broadcast only Broadcast Multicast Flooded Unicast Broadcast Multicast and Bbroadcast only types are only for ingress frames The egress rate only supports All type ...

Страница 87: ...ounter to meet the specified rate Ingress Enter the port effective ingress rate The default value is 0 Egress Enter the port effective egress rate The default value is 0 And then click Apply to apply the settings DMI Digital Monitoring Interface You can see the transceiver s status by ports and set up the action when detecting the exceptional value The action includes the following options Off The...

Страница 88: ...N configuration A Virtual LAN VLAN is a logical network grouping that limits the broadcast domain which would allow you to isolate network traffic so only the members of the VLAN will receive traffic from the same members of VLAN Basically creating a VLAN from a switch is logically equivalent of reconnecting a group of network devices to another Layer 2 switch However all the network devices are s...

Страница 89: ... treated as belonging to another single VLAN If the port based VLAN enabled the VLAN tagging is ignored In order for an end station to send packets to different VLAN groups it itself has to be either capable of tagging packets it sends with VLAN tags or attached to a VLAN aware bridge that is capable of classifying and tagging the packet with different VLAN ID based on not only default PVID but al...

Страница 90: ...Support 1 800 260 1312 International 00 1 952 941 7600 VLAN Port Based interface Click Add to add a new VLAN group The maximum VLAN group is up to 64 VLAN groups Entering the VLAN name group ID and grouping the members of VLAN group And then click Apply ...

Страница 91: ...al 00 1 952 941 7600 VLAN Port Based Add interface You will see the VLAN displays Use Delete button to delete unwanted VLAN Use Edit button to modify existing VLAN group Note Remember to execute the Save Configuration action otherwise the new configuration will lose when switch power off ...

Страница 92: ...ns a VLAN Identifier VID that indicates the VLAN numbers You can create Tag based VLAN and enable or disable GVRP protocol There are 256 VLAN groups to provide configure Enable 802 1Q VLAN the all ports on the switch belong to default VLAN VID is 1 The default VLAN can t be deleting GVRP allows automatic VLAN configuration between the switch and nodes If the switch is connected to a device with GV...

Страница 93: ...ct the port that wants to configure 3 Link Type there are 3 types of link type Access Link single switch only allow user to group ports by setting the same VID Trunk Link extended application of Access Link allow user to group ports by setting the same VID with 2 or more switches Hybrid Link Both Access Link and Trunk Link are available 4 Untagged VID assign the untagged frame VID 5 Tagged VID ass...

Страница 94: ... 1 952 941 7600 6 Click Apply 7 You can see each port setting in the below table on the screen Group Configuration Edit the existing VLAN Group 1 Select the VLAN group in the table list 2 Click Apply Group Configuration interface 3 You can Change the VLAN group name and VLAN ID 4 Click Apply ...

Страница 95: ...ect the connected device that is running STP or RSTP protocol RSTP System Configuration User can view spanning tree information about the Root Bridge User can modify RSTP state After modification click Apply button RSTP mode user must enable or disable RSTP function before configure the related parameters Priority 0 61440 a value used to identify the root bridge The bridge with the lowest value ha...

Страница 96: ... 40 Hello Time 1 10 the time that controls switch sends out the BPDU packet to check RSTP current status Enter a value between 1 through 10 Forward Delay Time 4 30 the number of seconds a port waits before changing from its Rapid Spanning Tree Protocol learning and listening states to the forwarding state Enter a value between 4 through 30 Note Follow the rule to configure the MAX Age Hello Time a...

Страница 97: ...mber 1 through 200000000 2 Priority Decide which port should be blocked by priority in LAN Enter a number 0 through 240 The value of priority must be the multiple of 16 3 P2P Some of the rapid state transactions that are possible within RSTP are dependent upon whether the port concerned can only be connected to exactly one other bridge i e it is served by a point to point LAN segment or can be con...

Страница 98: ...nfigure the port as an edge port set the port to True status 5 Non Stp The port includes the STP mathematic calculation True is not including STP mathematic calculation False is including the STP mathematic calculation 6 Click Apply RSTP Port Configuration interface SNMP Configuration Simple Network Management Protocol SNMP is the protocol developed to manage nodes servers workstations routers swi...

Страница 99: ... new community string set and remove unwanted community string 1 String fill the name of string 2 RO Read only Enables requests accompanied by this string to display MIB object information 3 RW Read write Enables requests accompanied by this string to display MIB object information and to set MIB objects 1 Click Add 2 To remove the community string select the community string that you have defined...

Страница 100: ...Create a trap manager by entering the IP address of the station and a community string To define management stations as trap manager and enter SNMP community strings and selects the SNMP version 1 IP Address Enter the IP address of trap manager 2 Community Enter the community string 3 Trap Version Select the SNMP trap version type v1 or v2c 4 Click Add 5 To remove the community string select the c...

Страница 101: ... Configure SNMP v3 context table Assign the context name of context table Click Add to add context name Click Remove to remove unwanted context name User Profile Configure SNMP v3 user table User ID set up the user name Authentication Password set up the authentication password Privacy Password set up the private password Click Add to add context name Click Remove to remove unwanted context name ...

Страница 102: ...Transition Networks SISGM1040 244 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 SNMP V3 configuration interface ...

Страница 103: ...t name Access Table Configure SNMP v3 access table Context Prefix Set up the context name Group Name Set up the group Security Level Set up the access level Context Match Rule Select the context match rule Read View Name Set up the read view Write View Name Set up the write view Notify View Name Set up the notify view Click Add to add context name Click Remove to remove unwanted context name MIBvi...

Страница 104: ...mes of the middle queue and 8 frames of the high queue will be processed at the same time in accordance with the 8 4 2 1 policy rule Use the strict priority scheme Always higher queue will be processed first except higher queue is empty Priority Type there are 5 priority type selections available Disable means no priority type is selected Port base the port priority will follow the Port base that ...

Страница 105: ...Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Click Apply QoS Configuration interface Port Base Priority Configure per port priority level Port each port has 4 priority levels High Middle Low and Lowest Click Apply ...

Страница 106: ...IP packet that has received For example user set the TOS level 25 is high The port 1 is following the TOS priority policy only When the port 1 packet received the system will check the TOS value of the received IP packet If the TOS value of received IP packet is 25 priority high and then the packet priority will have highest priority Click Apply IGMP Configuration The Internet Group Management Pro...

Страница 107: ...dicated in the report message Leave Group A message sent by a host to the querier to indicate that the host has quit being a member of a specific multicast group The switch support IP multicast you can enable IGMP protocol on web management s switch setting advanced page then displays the IGMP snooping information IP multicast addresses range are from 224 0 0 0 through 239 255 255 255 IGMP Protoco...

Страница 108: ... place command to other switches in the X Ring group If there are 2 or more switches in master mode then software will select the switch with lowest MAC address number as the ring master The X Ring master ring mode will be enabled by the X Ring configuration interface Also user can identify the switch as the ring master from the R M LED panel of the LED panel on the switch The system also supports...

Страница 109: ...et up one of port on the switch to be the Dual Homing port In an X Ring group maximum Dual Homing port is one Dual Homing only work when the X Ring function enable And then click Apply to apply the configuration X ring Interface Note 1 When X Ring function is enabled user must disable the RSTP first X Ring and RSTP function cannot exist at the same time 2 Remember to execute the Save Configuration...

Страница 110: ...e server System Configuration After enabling the IEEE 802 1X function you can configure the parameters of this function 1 IEEE 802 1x Protocol enable or disable 802 1x protocol 2 Radius Server IP set the Radius Server IP address 3 Server Port set the UDP destination port for authentication requests to the specified Radius Server 4 Accounting Port set the UDP destination port for accounting request...

Страница 111: ... and Authorize Use Space key change the state value Reject the specified port is required to be held in the unauthorized state Accept the specified port is required to be held in the Authorized state Authorized the specified port is set to the Authorized or Unauthorized state in accordance with the outcome of an authentication exchange between the Supplicant and the authentication server Disable T...

Страница 112: ...it next EAPOL PDU during an authentication session 3 Supplicant Timeout set the period of time the switch waits for a supplicant response to an EAP request 4 Server Timeout set the period of time the switch waits for a server response to an authentication request 5 Max Requests set the number of authentication that must time out before authentication fails and the authentication session ends 6 Rea...

Страница 113: ...h This saves the switch from having to re learn a device s MAC address when the disconnected or powered off device is active on the network again You can add modify delete a static MAC address Add the Static MAC Address You can add static MAC address in switch MAC table 1 MAC Address Enter the MAC address of the port that should permanently forward traffic regardless of the device network activity...

Страница 114: ...800 260 1312 International 00 1 952 941 7600 Static MAC Addresses interface MAC Filtering By filtering MAC address the switch can easily filter pre configure MAC address and reduce the un safety You can add and delete filtering MAC address MAC Filtering interface ...

Страница 115: ...ete the MAC address from filtering table select the MAC address and click Delete All MAC Addresses You can view the port that connected device s MAC address and related devices MAC address 1 Select the port 2 The selected port of static MAC address information will be displayed here 3 Click Clear MAC Table to clear the current port static MAC address information on screen All MAC Address interface...

Страница 116: ...t to reset all configurations to the default value Factory Default interface Save Configuration Save all configurations that you have made in the system To ensure the all configuration will be saved Click Save to save the all configuration to the flash memory Save Configuration interface System Reboot Reboot the switch in software reset Click Reboot to reboot the system ...

Страница 117: ...le for 1000Mbps connections Also be sure that the length of any twisted pair connection does not exceed 100 meters 328 feet Diagnosing LED Indicators the Switch can be easily monitored through panel indicators which describes common problems you may encounter and where you can find possible solutions to assist in identifying problems IF the power indicator does not light on when the power cord is ...

Отзывы: