Transition Networks
S4224 Web User Guide
33558 Rev. C
Page 88 of 669
Sample Type
The method of sampling the selected variable and calculating the value to be compared against the
thresholds, possible sample types are:
Absolute
: Get the sample directly.
Delta
: Calculate the difference between samples (default).
Value
The value of the statistic during the last sampling period.
Startup Alarm
The method of sampling the selected variable and calculating the value to be compared against the
thresholds. The valid sample types are:
Rising
:
Trigger alarm when the first value is larger than the rising threshold.
Falling
:
Trigger alarm when the first value is less than the falling threshold.
RisingOrFalling
:
Trigger alarm when the first value is larger than the rising threshold or less than
the falling threshold (default).
Rising Threshold
Rising threshold value (
-2147483648
-
2147483647
). The Rising Threshold must be larger than
the Falling Threshold.
Rising Index
Rising event index (
1
-
65535
). The Rising Threshold must be larger than the Falling Threshold.
Falling Threshold
Falling threshold value (
-2147483648
-
2147483647
). The Falling Threshold must be smaller than
the Rising Threshold.
Falling Index
Falling event index (
1
-
65535
). The Falling Index must be smaller than the Rising Index.
Buttons
Add New Entry
: Click to add a new community entry.
Save
: Click to save changes.
Reset
: Click to undo any changes made locally and revert to previously saved values.