Transition Networks
S4224 Web User Guide
33558 Rev. C
Page 132 of 669
Static ARP Inspection
The
Configuration
>
Security
>
Network
>
ARP
Inspection
>
Static Table
menu path provides the
default Static ARP Inspection
rules
. The switch supports a maximum of 256 rules
.
Click the
Add New
Entry
button to display the entry table.
The Static ARP Inspection Table parameters are explained below.
Delete
Check to delete the entry. It will be deleted during the next save.
Port
The logical port for the settings.
VLAN ID
The VLAN ID (VID) for the settings.
MAC Address
Allows Source MAC address in ARP request packets (e.g., enter 00-c0-f2-56-08-b0).
IP Address
Allows Source IP address in ARP request packets.
Add New Entry
Click to add a new entry to the Static ARP Inspection table. Specify the Port, VLAN ID, MAC address,
and IP address for the new entry. Click "Save" when done.
Buttons
Save
: Click to save changes.
Reset
: Click to undo any changes made locally and revert to previously saved values.
Add New Entry
: Click to add a new entry to the Static ARP Inspection table. See above.