Message
:
Internet Explorer cannot display the webpage
Meaning
: The S4224 web interface connection via Microsoft Internet Explorer is down.
Recovery
:
1. Try reconnecting via the S4224 web interface in IE.
2. At the S4224 CLI prompt, press the
Enter
key.
3. Enter the CLI command “
config default keep_ip
” and press the
Enter
key. For example:
>
config default keep_ip
>
4. Try reconnecting in IE.
5. If necessary, try another supported web browser.
Problem
: The S4224 screen locks up or displays incorrectly in Internet Explorer.
Description
: Internet Explorer 9 has some glitches in its operations. Some web pages do not render
correctly with IE because the web pages were designed for earlier functions.
Resolution
:
1. Enable compatibility view in Internet Explorer (at IE >
Tools
>
Compatibility
View
).
2. Continue operation.
Message
:
The Connection has timed out
Meaning
: The S4224 switch cannot communicate with the PC after enabling Flow Control from the
Configuration
>
Port
>
Configuration
menu path. Increasing the CONSOLE Port Max Frame size to
the tagged frame length fixes the problem.
Recovery
:
1.
Change the MGMT port to
10056
as the default frame size.
Problem
:
A Reboot will stop Fault Management and Performance Management measurements.
Meaning
:
After a system reboot, the MEP PM and FM become disabled.
Recovery
:
At
Configuration
>
MEP
>
MEP
Configuration
, re-enable the FM (LB, LT, TST, AIS,
LCK) and PM (Loss Measurement and Delay Measurement) after a system Reboot.