Technical Specifications 

For use with Transition Networks Model CBFTF10xx-10x or equivalent. 
Standards  

 

IEEE Std. 802.3u, 802.3x 

Data Rate  

 

10 Mbps; 100 Mbps 

Weight  

 

1 lbs. [0.45 kg] 

Power Consumption   3 watts 
Max. Packet Size:  

2048 bytes untagged bytes 

 

 

 

2044 bytes tagged bytes 

Filtering & Forwarding   14,880 pps for Ethernet; Rate 148,800 pps for Fast Ethernet 
Dimensions  

 

Width: 0.86” [22 mm] x Depth: 5.0” [127 mm] x Height: 3.4” [86 mm] 

Power Consumption   4.0 Watts 
Environment    

See chassis specifications

 

Regulatory Compliance  FCC Class A, CISPR22/EN55022 
 

 

 

Class A, EN55024, EN61000, CE Mark 

MTBF    

 

Greater than 250,000 hours (MIL-HDBK-217F) 

 

 

 

Greater than 687,500 hours (Bellcore7 V5.0) 

Warranty  

 

Lifetime 

For current information on the 

CBFTF10xx-10x 

see the online user guide at 

https://www.transition.com

Product is certified by the manufacturer to comply with DHHS Rule 21/CFR, Subchapter J applicable at 

the date of manufacture. 
WARNING: Visible and invisible laser radiation when open. Do not stare into the beam or view the beam 

directly with optical instruments. Failure to observe this warning could result in an eye injury or 

blindness. 
WARNING: Use of controls, adjustments or the performance of procedures other than those specified 

herein may result in hazardous radiation exposure. 
The fiber optic transmitters on this device meet Class I Laser safety requirements per IEC-825/CDRH 

standards and comply with 21 CFR1040.10 and 21CFR1040.11. 
*MTBF is estimated using the predictability method. This method is based on MIL-217F and Bellcore 

standards at 40°C ambient temperature, typical enclosure heat rise of 10°C, and nominal operating 

conditions and parameters. Installation and configuration specific MTBF estimates are available upon 

request. Contact Technical Support. 
CAUTION: Copper based media ports, e.g., Twisted Pair (TP) Ethernet, USB, RS232, RS422, RS485, DS1, 

DS3, Video Coax, etc., are intended to be connected to intrabuilding (inside plant) link segments that are 

not subject to lightening transients or power faults. Copper based media ports, e.g., Twisted Pair (TP) 

Ethernet, USB, RS232, RS422, RS485, DS1, DS3, Video Coax, etc., are NOT to be connected to inter-

building (outside plant) link segments that are subject to lightening transients or power faults. 
Failure to observe this caution could result in damage to equipment. 

Содержание CBFTF10xx-1xx

Страница 1: ...er J4 5 Install the Slide in Module 5 Install the Twisted Pair Copper Cable 6 Install the Fiber Cable 6 Operation 7 Status LEDs 7 Product Features 8 Cable Specifications 10 Technical Specifications 12...

Страница 2: ...19 105 10 100BASE TX RJ 45 100 m 328 ft to 100BASE FX 1310nm SM LC 20 km 12 4 mi Link Budget 17 3 dB CBFTF1040 105 10 100BASE TX RJ 45 100 m 328 ft to 100BASE X SFP Slot empty Single Fiber Products Re...

Страница 3: ...ge 3 of 15 DIP Switch and Jumper Locations PCB 11293 Rev A is shown below Installation CAUTION Wear a grounding device and observe electrostatic discharge precautions when setting the 6 position DIP s...

Страница 4: ...switches 2 and 3 2 Speed only functions whan Switch 1 is Down up 100 Mb s operation on the copper port down 10 Mb s operation on the copper port 3 Copper Mode Duplex only functions whan Switch 1 is D...

Страница 5: ...e is determined by the most recently saved on board settings Hardware The media converter mode is determined by the 6 position switch settings listed above Install the Slide in Module To install the C...

Страница 6: ...the CBFTF10xx 10x media converter 3 Connect the RJ 45 connector at the other end of the cable to the RJ 45 port on the other device switch workstation etc Install the Fiber Cable 1 Locate an IEEE 803...

Страница 7: ...x ON full duplex fiber connection OFF half duplex fiber connection FLNK Fiber Link ON Fiber link connection Blinking Fiber network activity PWR Power ON Power applied to chassis card TSPD Twisted Pair...

Страница 8: ...is being forced into a link down blinks on and off every 2 seconds while the LPT condition exists Far end Fault When a fault occurs on an incoming fiber link 1 the media converter transmits a Far End...

Страница 9: ...x network the maximum cable lengths are determined by the round trip delay limitations of each Fast Ethernet collision domain A collision domain is the longest path between any two terminal devices e...

Страница 10: ...ansmitter Power min 15 0 dBm max 8 0 dBm Fiber optic Receiver Sensitivity min 31 0 dBm max 8 0 dBm Link Budget 16 0 dB CBFTF1015 105 single mode Fiber optic Transmitter Power min 5 0 dBm max 2 0 dBm F...

Страница 11: ...14 0 dBm Fiber optic Receiver Sensitivity min 30 0 dBm max 14 0 dBm Link Budget 11dB Copper Cable maximum cable distance 100 meters Category 3 Minimum requirement for 10 Mb s operation Gauge 24 to 22...

Страница 12: ...beam directly with optical instruments Failure to observe this warning could result in an eye injury or blindness WARNING Use of controls adjustments or the performance of procedures other than those...

Страница 13: ...e Contact Us below YES Proceed to step 3 3 Is the FLNK fiber pair link LED lit NO Check the fiber cables for proper connection Verify that the TX and RX cables are connected to the RX and TX ports res...

Страница 14: ...n com customerservice transition com Address Transition Networks 10900 Red Circle Drive Minnetonka MN 55343 U S A Web https www transition com Compliance Information Declaration of Conformity CE Mark...

Страница 15: ...ateur de prende les measures sp cifiques appropri es In accordance with European Union Directive 2002 96 EC of the European Parliament and of the Council of 27 January 2003 Transition Networks will ac...

Отзывы: