background image

Transition Networks 

 

 

 

 

 

 

CBFTF10xx-1xx User Guide 

33403 Rev. E 

https://www.transition.com 

Page 15 of 15 

frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful 

interference to radio communications. 
Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will 

be required to correct the interference at the user's own expense. 

Canadian regulations 

This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio 

interference regulations of the Canadian Department of Communications. 
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables aux 

appareils numériques de la Class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le 

ministère des Communications du Canada. 

European regulations 

Warning This is a Class A product. In a domestic environment this product may cause radio interference in which 

case the user may be required to take adequate measures. 
Achtung ! Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses 

Gerätes Rundfunkstörungen auftreten. In diesem Fäll is der Benutzer für Gegenmaßnahmen verantwortlich. 

Attention ! 
Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de créer des interférences 

radioélectriques, il appartiendra alors à l'utilsateur de prende les measures spécifiques appropriées. 

 
In accordance with European Union Directive 2002/96/EC of the European Parliament and of the 
Council of 27 January 2003, Transition Networks will accept post usage returns of this product for 

proper disposal. The contact information for this activity can be found in the 'Contact Us' portion of 

this document. 

 

CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK. Failure to 

observe this caution could result in damage to the public telephone network. 
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EGMitgliedstaaten verstösst 

gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur Angleichung der 

Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der 

gegenseitigen Anerkennung ihrer Konformität. 

Record of Revisions 

 

Rev 

Date 

Notes 

6/5/08 

Initial release. 

11/21/08  Switch positions 2 and 3 swapped: Speed and Duplex. Added part # SBFTF1040-105 

6/29/10 

Added notes to DIP switch section.  Added copper base media cautions statement to tech spec 

section. Added CBFTF1012-105.   

10/14/10   Corrected link budgets on CBFTF1015, 16, 17-105. 

10/14/16  UpdatedDIP switch and jumper information; updated format and contact information. 

 

 

Trademark notice: All trademarks and registered trademarks are the property of their respective owners. 

 

Copyright restrictions: © 2008-2016 Transition Networks. All rights reserved. No part of this work may be reproduced or used 

in any form or by any means - graphic, electronic or mechanical - without written permission from Transition Networks. 

 

Содержание CBFTF10xx-1xx

Страница 1: ...er J4 5 Install the Slide in Module 5 Install the Twisted Pair Copper Cable 6 Install the Fiber Cable 6 Operation 7 Status LEDs 7 Product Features 8 Cable Specifications 10 Technical Specifications 12...

Страница 2: ...19 105 10 100BASE TX RJ 45 100 m 328 ft to 100BASE FX 1310nm SM LC 20 km 12 4 mi Link Budget 17 3 dB CBFTF1040 105 10 100BASE TX RJ 45 100 m 328 ft to 100BASE X SFP Slot empty Single Fiber Products Re...

Страница 3: ...ge 3 of 15 DIP Switch and Jumper Locations PCB 11293 Rev A is shown below Installation CAUTION Wear a grounding device and observe electrostatic discharge precautions when setting the 6 position DIP s...

Страница 4: ...switches 2 and 3 2 Speed only functions whan Switch 1 is Down up 100 Mb s operation on the copper port down 10 Mb s operation on the copper port 3 Copper Mode Duplex only functions whan Switch 1 is D...

Страница 5: ...e is determined by the most recently saved on board settings Hardware The media converter mode is determined by the 6 position switch settings listed above Install the Slide in Module To install the C...

Страница 6: ...the CBFTF10xx 10x media converter 3 Connect the RJ 45 connector at the other end of the cable to the RJ 45 port on the other device switch workstation etc Install the Fiber Cable 1 Locate an IEEE 803...

Страница 7: ...x ON full duplex fiber connection OFF half duplex fiber connection FLNK Fiber Link ON Fiber link connection Blinking Fiber network activity PWR Power ON Power applied to chassis card TSPD Twisted Pair...

Страница 8: ...is being forced into a link down blinks on and off every 2 seconds while the LPT condition exists Far end Fault When a fault occurs on an incoming fiber link 1 the media converter transmits a Far End...

Страница 9: ...x network the maximum cable lengths are determined by the round trip delay limitations of each Fast Ethernet collision domain A collision domain is the longest path between any two terminal devices e...

Страница 10: ...ansmitter Power min 15 0 dBm max 8 0 dBm Fiber optic Receiver Sensitivity min 31 0 dBm max 8 0 dBm Link Budget 16 0 dB CBFTF1015 105 single mode Fiber optic Transmitter Power min 5 0 dBm max 2 0 dBm F...

Страница 11: ...14 0 dBm Fiber optic Receiver Sensitivity min 30 0 dBm max 14 0 dBm Link Budget 11dB Copper Cable maximum cable distance 100 meters Category 3 Minimum requirement for 10 Mb s operation Gauge 24 to 22...

Страница 12: ...beam directly with optical instruments Failure to observe this warning could result in an eye injury or blindness WARNING Use of controls adjustments or the performance of procedures other than those...

Страница 13: ...e Contact Us below YES Proceed to step 3 3 Is the FLNK fiber pair link LED lit NO Check the fiber cables for proper connection Verify that the TX and RX cables are connected to the RX and TX ports res...

Страница 14: ...n com customerservice transition com Address Transition Networks 10900 Red Circle Drive Minnetonka MN 55343 U S A Web https www transition com Compliance Information Declaration of Conformity CE Mark...

Страница 15: ...ateur de prende les measures sp cifiques appropri es In accordance with European Union Directive 2002 96 EC of the European Parliament and of the Council of 27 January 2003 Transition Networks will ac...

Отзывы: