Transition Networks CBFTF10xx-1xx Скачать руководство пользователя страница 11

Transition Networks 

 

 

 

 

 

 

CBFTF10xx-1xx User Guide 

33403 Rev. E 

https://www.transition.com 

Page 11 of 15 

CBFTF1029-107, CBFTF1029-108  

single mode 

Fiber-optic Transmitter Power:    

min: -8.0 dBm    

max: -3.0 dBm 

Fiber-optic Receiver Sensitivity:  

 min: -33.0 dBm  

max: -3.0 dBm 

Link Budget:    

 

 

25.0 dB 

CBFTF1035-105  

 

 

multimode 

Fiber-optic Transmitter Power:    

min: 0.0 dBm    

max: 5.0 dBm 

Fiber-optic Receiver Sensitivity:   

min: -36.0 dBm   

max: -3.0 dBm 

Link Budget:    

 

 

36dB 

CBFTF1039-105  

 

 

multimode 

Fiber-optic Transmitter Power:    

min: -19.0 dBm   

max: -14.0 dBm 

Fiber-optic Receiver Sensitivity:   

min: -30.0 dBm   

max: -14.0 dBm 

Link Budget:    

 

 

11dB 

 

 

Copper Cable 

maximum cable distance: 100 meters 

Category 3: 

(Minimum requirement for 10 Mb/s operation) 

Gauge    

 

 

 

24 to 22 AWG 

Attenuation    

 

 

11.5 dB/100m @ 5-10 MHz 

Category 5: 

(Minimum requirement for 100 Mb/s operation) 

Gauge    

 

 

 

24 to 22 AWG 

Attenuation    

 

 

22.0 dB /100m @ 100 MHz 

 

Straight-through (MDI) or crossover (MDI-X) twisted-pair cable must be used. 

 

Shielded twisted-pair (STP) or unshielded twisted-pair (UTP) may be used. 

 

Pins 1&2 and 3&6 are the two active pairs in an Ethernet network . 

 

Use only dedicated wire pairs for the active pins 

(e.g., blue/white & white/blue, orange/white & 

white/orange, etc.) 

 

Do not use flat or silver satin wire. 

 

 

Содержание CBFTF10xx-1xx

Страница 1: ...er J4 5 Install the Slide in Module 5 Install the Twisted Pair Copper Cable 6 Install the Fiber Cable 6 Operation 7 Status LEDs 7 Product Features 8 Cable Specifications 10 Technical Specifications 12...

Страница 2: ...19 105 10 100BASE TX RJ 45 100 m 328 ft to 100BASE FX 1310nm SM LC 20 km 12 4 mi Link Budget 17 3 dB CBFTF1040 105 10 100BASE TX RJ 45 100 m 328 ft to 100BASE X SFP Slot empty Single Fiber Products Re...

Страница 3: ...ge 3 of 15 DIP Switch and Jumper Locations PCB 11293 Rev A is shown below Installation CAUTION Wear a grounding device and observe electrostatic discharge precautions when setting the 6 position DIP s...

Страница 4: ...switches 2 and 3 2 Speed only functions whan Switch 1 is Down up 100 Mb s operation on the copper port down 10 Mb s operation on the copper port 3 Copper Mode Duplex only functions whan Switch 1 is D...

Страница 5: ...e is determined by the most recently saved on board settings Hardware The media converter mode is determined by the 6 position switch settings listed above Install the Slide in Module To install the C...

Страница 6: ...the CBFTF10xx 10x media converter 3 Connect the RJ 45 connector at the other end of the cable to the RJ 45 port on the other device switch workstation etc Install the Fiber Cable 1 Locate an IEEE 803...

Страница 7: ...x ON full duplex fiber connection OFF half duplex fiber connection FLNK Fiber Link ON Fiber link connection Blinking Fiber network activity PWR Power ON Power applied to chassis card TSPD Twisted Pair...

Страница 8: ...is being forced into a link down blinks on and off every 2 seconds while the LPT condition exists Far end Fault When a fault occurs on an incoming fiber link 1 the media converter transmits a Far End...

Страница 9: ...x network the maximum cable lengths are determined by the round trip delay limitations of each Fast Ethernet collision domain A collision domain is the longest path between any two terminal devices e...

Страница 10: ...ansmitter Power min 15 0 dBm max 8 0 dBm Fiber optic Receiver Sensitivity min 31 0 dBm max 8 0 dBm Link Budget 16 0 dB CBFTF1015 105 single mode Fiber optic Transmitter Power min 5 0 dBm max 2 0 dBm F...

Страница 11: ...14 0 dBm Fiber optic Receiver Sensitivity min 30 0 dBm max 14 0 dBm Link Budget 11dB Copper Cable maximum cable distance 100 meters Category 3 Minimum requirement for 10 Mb s operation Gauge 24 to 22...

Страница 12: ...beam directly with optical instruments Failure to observe this warning could result in an eye injury or blindness WARNING Use of controls adjustments or the performance of procedures other than those...

Страница 13: ...e Contact Us below YES Proceed to step 3 3 Is the FLNK fiber pair link LED lit NO Check the fiber cables for proper connection Verify that the TX and RX cables are connected to the RX and TX ports res...

Страница 14: ...n com customerservice transition com Address Transition Networks 10900 Red Circle Drive Minnetonka MN 55343 U S A Web https www transition com Compliance Information Declaration of Conformity CE Mark...

Страница 15: ...ateur de prende les measures sp cifiques appropri es In accordance with European Union Directive 2002 96 EC of the European Parliament and of the Council of 27 January 2003 Transition Networks will ac...

Отзывы: