TUHM AIRFLOW - COOLING
NOTE:
CONTINUOUS fan mode during
COOLING operation may not be
appropriate in humid climates. If the
indoor air exceeds 60% relative humidity
or simply feels uncomfortably humid,
it is recommended that the fan only be
used in the AUTO mode.
0.1
0.3
0.5
0.7
0.9
CFM
356
476
488
511
519
Watts
29
67
97
132
167
CFM
389
504
516
538
545
Watts
32
71
102
138
174
CFM
422
533
544
565
572
Watts
36
75
107
144
181
CFM
455
561
566
589
592
Watts
39
79
111
150
187
CFM
487
589
600
619
624
Watts
43
84
119
158
197
CFM
537
631
655
669
673
Watts
50
92
130
171
212
CFM
586
674
684
700
702
Watts
57
101
139
182
223
CFM
619
695
717
727
733
Watts
63
106
150
193
236
CFM
515
613
623
641
646
Watts
47
88
124
164
204
CFM
559
650
660
677
681
Watts
53
96
133
175
215
CFM
602
688
698
713
716
Watts
60
104
143
186
228
CFM
646
707
737
748
752
Watts
68
112
156
200
243
CFM
690
763
772
785
785
Watts
76
123
165
211
255
CFM
764
816
778
847
844
Watts
86
137
180
231
275
CFM
821
876
884
892
890
Watts
108
159
206
256
303
CFM
937
968
977
985
984
Watts
136
193
241
295
343
CFM
673
749
758
771
772
Watts
73
119
161
206
250
CFM
732
791
756
766
818
Watts
79
129
160
203
268
CFM
783
843
852
861
860
Watts
98
147
193
242
288
CFM
848
894
908
917
917
Watts
110
163
212
262
308
CFM
892
937
945
951
947
Watts
129
182
232
284
333
CFM
972
1015
972
957
1036
Watts
160
213
262
312
374
CFM
1057
1078
1085
1085
1078
Watts
191
249
306
360
415
CFM
1115
1137
1142
1140
1139
Watts
214
275
333
388
447
CFM
832
885
894
901
899
Watts
111
162
210
260
308
CFM
898
942
950
955
951
Watts
131
184
234
286
336
CFM
964
998
1006
1009
1004
Watts
154
209
262
314
366
CFM
1039
1065
1073
1074
1075
Watts
181
237
292
344
402
CFM
1095
1111
1118
1116
1108
Watts
208
268
326
380
436
CFM
1189
1212
1214
1149
1207
Watts
257
320
380
435
500
CFM
1292
1280
1285
1278
1201
Watts
317
383
448
501
508
CFM
1326
1317
1361
1242
1166
Watts
366
433
495
510
509
Notes:
1. * First letter may be "A" or "T".
2. ^ Letter may be "A" through "Z"
3. ** Factory setting.
4. Continuous Fan Setting: Heating or cooling airflow is approximately 50% of selected
cooling value.
5. LOW 350 cfm/ton is recommended for variable speed application for COMFORT & HUMID
CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting.
C
ooling
Unit
Outdoor
Airflow
Setting
External Static Pressure
1.5
290 CFM/ton
310 CFM/ton
330 CFM/ton
350 CFM/ton
370 CFM/ton
400 CFM/ton
430 CFM/ton
450 CFM/ton
2
290 CFM/ton
310 CFM/ton
330 CFM/ton
350 CFM/ton
370 CFM/ton
400 CFM/ton
310 CFM/ton
330 CFM/ton
350 CFM/ton
370 CFM/ton
400 CFM/ton
430 CFM/ton
430 CFM/ton
450 CFM/ton
*UHMB060ACV3VB^
Furnace Cooling Airflow (CFM) and Power (Watts) vs. External Static
Pressure With Filter
450 CFM/ton
3
290 CFM/ton
310 CFM/ton
2.5
290 CFM/ton
330 CFM/ton
350 CFM/ton
370 CFM/ton
400 CFM/ton
430 CFM/ton
450 CFM/ton