8
Pub. No. 22-1840-14
TUHM AIRFLOW - HEATING
0.1
0.3
0.5
0.7
0.9
CFM
393
504
512
546
560
Temp. Rise
73
57
56
53
51
Watts
43
81
112
142
140
CFM
435
541
549
580
593
Temp. Rise
66
53
52
50
49
Watts
46
86
119
150
148
CFM
472
573
580
609
621
Temp. Rise
61
50
50
47
46
Watts
50
90
125
159
155
CFM
545
636
644
667
676
Temp. Rise
53
45
45
43
43
Watts
60
103
141
177
169
CFM
565
653
660
682
691
Temp. Rise
68
59
58
57
56
Watts
64
107
145
182
172
CFM
622
703
710
727
734
Temp. Rise
62
55
54
53
53
Watts
75
120
161
199
183
CFM
671
745
752
766
771
Temp. Rise
58
52
51
50
50
Watts
86
133
175
215
192
CFM
769
831
837
843
846
Temp. Rise
50
46
46
46
46
Watts
114
164
210
250
211
CFM
791
849
856
861
862
Temp. Rise
65
61
60
60
60
Watts
121
171
219
258
215
CFM
867
916
922
921
920
Temp. Rise
59
56
56
56
56
Watts
148
201
251
290
230
CFM
932
972
979
973
970
Temp. Rise
55
53
53
53
53
Watts
174
229
282
319
243
CFM
1063
1086
1092
1076
1069
Temp. Rise
48
47
47
48
48
Watts
236
295
353
384
268
100%
(high)
Heat
Low
830
Medium Low
900
Medium**
960
High
1080
65%
(medium)
Heat
Low
623
Medium Low
675
Medium**
720
High
810
Medium Low
504
Medium**
538
High
605
H
eat
ing
*UHMB060ACV3VB^
Furnace Heating Airflow (CFM) and Power (watts) vs. External Static Pressure With Filter
Airflow
Setting
Target Airflow
(See Note 5)
External Static Pressure
40%
(low)
Heat
Low
465
0.1
0.3
0.5
0.7
0.9
CFM
512
564
581
538
572
Temp. Rise
70
63
62
66
62
Watts
45
77
112
109
146
CFM
586
634
649
606
634
Temp. Rise
61
56
55
59
56
Watts
57
90
129
127
177
CFM
661
704
717
673
696
Temp. Rise
54
51
50
53
51
Watts
71
106
148
146
207
CFM
772
809
819
774
789
Temp. Rise
46
44
44
46
45
Watts
99
136
184
176
253
CFM
757
794
805
760
776
Temp. Rise
67
63
63
66
65
Watts
95
132
179
172
246
CFM
862
893
901
855
864
Temp. Rise
59
56
56
59
58
Watts
127
165
217
202
289
CFM
967
992
997
951
951
Temp. Rise
52
51
51
53
53
Watts
165
205
262
235
332
CFM
1125
1139
1141
1093
1083
Temp. Rise
45
44
44
46
47
Watts
233
276
341
288
395
CFM
1084
1101
1104
1056
1048
Temp. Rise
65
64
63
66
67
Watts
214
256
319
273
379
CFM
1230
1238
1237
1188
1170
Temp. Rise
57
57
57
59
60
Watts
286
331
401
325
437
CFM
1376
1375
1370
1320
1292
Temp. Rise
51
51
51
53
54
Watts
369
418
495
381
496
CFM
1595
1580
1570
1519
1474
Temp. Rise
44
44
45
46
48
Watts
398
470
522
522
529
Target Airflow
(See Note 5)
External Static Pressure
40%
(low)
Heat
Low
571
Medium Low
643
Medium**
714
High
821
65%
(medium)
Heat
Low
806
Medium Low
907
Medium**
1008
High
1159
H
eat
ing
*UHMB080ACV3VB^
Furnace Heating Airflow (CFM) and Power (Watts) vs. External Static Pressure With Filter
Airflow
Setting
100%
(high)
Heat
Low
1120
Medium Low
1260
Medium**
1400
High
1610
Notes:
1. * First letter may be "A" or "T".
3. ** Factory setting.
2. ^ Letter may be “A” through “Z”.
4. Continuous Fan Setting: Heating or cooling airflow is approximately 50% of selected
cooling value.
5. LOW 350 cfm/ton is recommended for variable speed application for COMFORT & HUMID
CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting.
6. Target airflow is field selectable for high (100%) heat. Target airflow for low and medium
heat are percentages of high heat and are not field selectable.