32-5052-06
9
User’s Information
NOTE: On LP (propane) units, due to variations in BTU
content and altitude, servicing may be required at shorter
intervals.
5. HEAT EXCHANGER / FLUE PIPE – These items must
be inspected for signs of corrosion, and/or deterioration
at the beginning of each heating season by a qualified
service technician and cleaned annually for best opera-
tion.
6. CIRCUIT PROTECTION – If blower or gas valve fail
to operate, the cause could be the circuit breaker or
a loose or blown fuse. Replace fuse or reset circuit
breaker.
7. OPERATION – Your warm air furnace should not be
operated in a corrosive atmosphere. Paint solvents,
cleaning chemicals, spray propellants, and bleaches
should not be used in the vicinity of the furnace during
normal operation.
8. CONDENSATE DRAINS – If you have a cooling coil in-
stalled with your furnace, condensate drains should be
checked and cleaned periodically to assure that conden-
sate can drain freely from coil to drain. If condensate
cannot drain freely water damage could occur.
9. AIR CIRCULATION – To ensure increased comfort, the
blower on this unit may be operated continuously for
both heating and cooling. This will result in constantly
filtered air and aid in maintaining more even tempera-
tures by avoiding temperature stratification through-
out the conditioned area. To accomplish constant air
circulation, set your thermostat fan switch to “ON”.
Continuous fan mode during cooling operation may
not be appropriate in humid climates. If the indoor air
exceeds 60% relative humidity or simply feels uncom-
fortably humid, it is recommended that the fan only be
used in the AUTO mode.