WaRnInG

!

CaRbon MonoXIDe PoISonInG haZaRD

FaILuRe To FoLLoW The InSTaLLaTIon anD oPeRa-

TIon InSTRuCTIonS FoR The venTInG SySTeM’S 

oPeRaTIon CouLD ReSuLT In CaRbon MonoXIDe 

PoISonInG oR DeaTh.

WaRnInG

!

SaFeTy WaRnInG

boDILy InjuRy Can ReSuLT FRoM hIGh voLTaGe 

eLeCTRICaL CoMPonenTS, FaST MovInG FanS, 

anD CoMbuSTIbLe GaS. DuRInG InSTaLLaTIon anD 

SeRvICInG, The eLeCTRICaL SuPPLy MuST be DIS-

ConneCTeD anD The MaIn GaS vaLve MuST be 

TuRneD oFF. 

FaILuRe To FoLLoW ThIS WaRnInG CouLD ReSuLT In 

PRoPeRTy DaMaGe, PeRSonaL InjuRy oR DeaTh.

 

WaRnInG

!

SaFeTy WaRnInG

To PRevenT InjuRy oR DeaTh Due To ConTaCT WITh 

MovInG PaRTS, TuRn The PoWeR To The FuRnaCe 

oFF beFoRe CLeanInG oR SeRvICInG The WhoLe 

houSe aIR CLeaneR.

FaILuRe To FoLLoW ThIS WaRnInG CouLD ReSuLT In 
PRoPeRTy DaMaGe, PeRSonaL InjuRy oR DeaTh.

 

WaRnInG

!

eLeCTRIC ShoCK haZaRD

TheSe SeRvICInG InSTRuCTIonS aRe FoR uSe by 

quaLIFIeD PeRSonneL onLy.  To ReDuCe The RISK oF 

eLeCTRIC ShoCK, Do noT PeRFoRM any SeRvICInG 

oTheR Than ThaT ConTaIneD In TheSe oPeRaTInG 

InSTRuCTIonS unLeSS you aRe quaLIFIeD To Do So.  

 

FaILuRe To FoLLoW ThIS WaRnInG CouLD ReSuLT In 

PRoPeRTy DaMaGe, PeRSonaL InjuRy oR DeaTh.

WaRnInG

!

The following warning complies with State of California law, Proposition 65.

ThIS PRoDuCT ConTaInS FIbeRGLaSS WooL InSuLaTIon!
Fiberglass dust and ceramic fibers are believed by the State of California to cause cancer through inhalation. 

Glasswool fibers may also cause respiratory, skin, or eye irritation.

PReCauTIonaRy MeaSuReS 

 

Avoid breathing fiberglass dust.

  Use a NIOSH approved dust/mist respirator.

  Avoid contact with the skin or eyes. Wear long-sleeved, 

loose-fitting clothing, gloves, and eye protection.

  Wash clothes separately from other clothing: rinse 

washer thoroughly.

  Operations such as sawing, blowing, tear-out, and 

spraying may generate fiber concentrations requiring 

additional respiratory protection. Use the appropriate 

NIOSH approved respirator in these situations.

FIRST aID MeaSuReS
eye Contact  – 

Flush eyes with water to remove dust. 

If symptoms persist, seek medical 

attention.

Skin Contact  – 

Wash affected areas gently with soap 

and warm water after handling.

 

DeaTh.

WaRnInG

!

SaFeTy WaRnInG

Do noT aTTeMPT To ManuaLLy LIGhT The FuRnaCe.    

FaILuRe To FoLLoW ThIS WaRnInG May ReSuLT In 

PeRSonaL InjuRy, PRoPeRTy DaMaGe, oR DeaTh. 

 

CauTIon

!

high voltage is present within the air cleaner for operation.  

Turn  the  power  off  and  wait  at  least  15  seconds  to  allow 

voltage to discharge.

CauTIon

!

If the furnace is shut down during the cold weather 

months, provisions must be taken to prevent freeze-up of 

all water pipes and water receptacles.

CauTIon

!

never operate your unit for either heating or cooling with 

filters removed. 

 

CauTIon

!

Do noT touch igniter. It is extremely hot. 

CauTIon

!

The combustion air for your furnace must be fresh uncon-

taminated air. Paints, varnishes, laundry bleaches, deter-

gents, many household cleaners, water softening salts, 

adhesives, and all such products release fumes contain-

ing compounds which could lead to early heat exchanger 

and vent system deterioration. Do noT store these types 

of products near your furnace.

Содержание TDD-ACV

Страница 1: ... other flammable vapors and liquids or combustible materials in the vicinity of this or any other appliance WhaT To Do IF you SMeLL GaS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire departm...

Страница 2: ...espiratory skin or eye irritation PReCauTIonaRy MeaSuReS Avoid breathing fiberglass dust Use a NIOSH approved dust mist respirator Avoid contact with the skin or eyes Wear long sleeved loose fitting clothing gloves and eye protection Wash clothes separately from other clothing rinse washer thoroughly Operations such as sawing blowing tear out and spraying may generate fiber concentrations requirin...

Страница 3: ...lating materials are combustible Never stop the heating system by shutting off the main power Furnaces must have air for proper performance There must be a free flow of fresh air sufficient for efficient com bustion and safe ventilation of your furnace Never store gasoline combustible materials or other flammable liquids or vapors near your furnace Carbon monoxide fire or smoke can cause serious b...

Страница 4: ... next step 5 Turn gas cock knob counterclockwise or the toggle switch to ON marker see illustration on this page Turn the external gas cock back to the on position if you expect the furnace to light 6 Replace the furnace front access panel 7 Turn on main electrical supply and set thermostat to de sired setting Combustion blower will start and ignition device will start to heat up After approximate...

Страница 5: ...L FURNACE Manual Main Gas Shut off Valve May Be Located on the Top or Bottom Side HORIZONTAL FURNACE GAS PIPING MAY BE FROM EITHER SIDE Typical UPFLOW Furnace in horizontal configuration shown AUTOMATIC GAS VALVE WITH MANUAL SHUTOFF AUTOMATIC GAS VALVE WITH MANUAL SHUTOFF MAIN MANUAL SHUTOFF VALVE MAIN MANUAL SHUTOFF VALVE GROUND UNION JOINT GROUND UNION JOINT DRIP LEG DRIP LEG AIR FLOW AIR FLOW L...

Страница 6: ...culates and filters the air in your home dust and dirt particles build up on the filter Exces sive accumulation can block the airflow forcing the unit to work harder to maintain desired temperatures And the harder your unit has to work the more energy it uses So you pay more any time your system is running with a dirty filter CauTIon High Voltage is present within the air cleaner for operation Tur...

Страница 7: ...ates continuously No Heat Vent motor is running Unusual Noise 1 Thermostat set incorrectly 2 Blown fuse or tripped circuit breaker 3 Failed component 4 Burner does not ignite 5 Main gas line turned off 6 Blower door removed or ajar 7 Lockout 1 Dirty air filtration system 2 Blocked supply or return registers Restricted or plugged furnace Condensate drain 1 Adjust thermostat See operating instructio...

Страница 8: ...und without sagging cracks gaps etc around the base so as to provide a seal between the support and the base e There are no obvious signs of deterioration of the furnace 2 BLOWERS The blower size and speed determine the air volume delivered by the furnace The blower mo tor bearings are factory lubricated and under normal operating conditions usually do not require servicing Annual cleaning of the ...

Страница 9: ...vicinity of the furnace during normal operation 8 CONDENSATE DRAINS If you have a cooling coil in stalled with your furnace condensate drains should be checked and cleaned periodically to assure that conden sate can drain freely from coil to drain If condensate cannot drain freely water damage could occur 9 AIR CIRCULATION To ensure increased comfort the blower on this unit may be operated continu...

Страница 10: ... limited warranty does not apply if the gas furnace was purchased direct i e from internet websites or auctions on an uninstalled basis Additionally this limited warranty will not apply unless the gas furnace is 1 installed by a licensed or qualified HVAC technician 2 applied and installed in accordance with the manufacturer s recommendations in its Installer s Guide and 3 in compliance with all i...

Страница 11: ...__________________________________________________________ Indoor Coil Serial Number______________________________________________________________________________ Indoor Coil Model Number______________________________________________________________________________ Date of Installation_____________________________________________________________________________________ Dealer______________________...