background image

10 

 

32-5052-06

User’s Information

Extended warranties are available from the manufacturer through your dealer.  The limited warranty is backed by the 

manufacturer and any representations made about extending the limited warranty would be backed by the manufac-

turer if and only if an extended warranty agreement was received 

from the manufacturer

.

Base Limited Warranty 

Gas Furnace 

TUD-R9V, TDD-R9V, TUD-AFV, TDD-ACV, TUD-ACV, TUX-AFV, TUH2, TDH2, TUH3, TDH3 (Parts Only) 

Models Less Than 20 Tons for Residential Use* 

This limited warranty is provided by the manufacturer to the original purchaser and to any succeeding owner of the real property to which the gas 

furnace is originally affixed, and applies to products purchased and retained for use within the U.S.A. and Canada. 
 
Beginning on January 1, 2010, R-22 refrigerant will no longer be used as a manufacturer-installed refrigerant as required by federal regulation. 

Following this date, depending on the availability of any remaining R-22 equipment, indoor model replacements may require that the entire system 

be R-410A compatible. Outdoor system components and possibly connecting line sets would need to be replaced in order to be compatible with 

indoor units containing R-410A refrigerant. Expenses associated with replacing system components that are not R-410A compatible will not be 
covered by the terms and conditions of the limited warranty. 

The limited warranty period begins when installation is complete and the gas furnace start-up procedure has been properly completed, verified by 

installer’s invoice or similar document. If installation completion and start-up date cannot be verified by installer’s invoice or similar document, this 
limited warranty coverage begins six (6) months after the date of manufacture based on the gas furnace serial number. 

 

If any functional part of your gas furnace fails because of a manufacturing defect within five (5) years from the date the limited warranty period 
begins, Warrantor will furnish without charge the required replacement part. Any other costs, such as local transportation, related service labor, 

diagnosis calls, refrigerant and related items are not included. 
 

In addition, if the heat exchanger fails because of a manufacturing defect within the sixth through twentieth year from the date the limited warranty 

period begins, Warrantor WILL AT ITS OPTION provide either a heat exchanger without charge, or allow a credit in the amount of the then current 
wholesale price of an equivalent heat exchanger toward the purchase price of a comparable heating unit. Any other costs, such as local 

transportation, related service labor, diagnosis calls, refrigerant and related items are not included. 

 
This limited warranty does not apply if the gas furnace was purchased direct (i.e. from internet websites or auctions) on an uninstalled basis. 

Additionally, this limited warranty will not apply unless the gas furnace is: (1) installed by a licensed or qualified HVAC technician, (2) applied and 
installed in accordance with the manufacturer’s recommendations in its Installer’s Guide, and (3) in compliance with all industry standards, 

national, state, and local codes. 

 
This limited warranty does not cover failure of your furnace if it is damaged while in your possession; including, but not limited to (1) damage 

caused by unreasonable use, (2) damage from failure to properly maintain as set forth in the Use and Care manual, (3) damage that is not 
considered a manufacturing defect, such as acts of God, malfunctions or failures resulting from fire, water, storms, lightning, earthquake, theft, riot, 

misuse, abuse, increased utility usage costs, or (4) performance problems due to improper selection/equipment match, installation or application. 

 
This limited warranty applies to product installed on or after 5/1/2009.  

 

Registered Limited Warranty Option 

If registered within 60 days of the original installation date, the limited warranty terms will be lengthened** as follows: heat exchanger – lifetime, all 
other functional parts – ten (10) years. 

 

**Registered Limited Warranty lengthened terms only apply to owner occupied properties and single family properties on a US military installation, 
are non-transferable and do not apply to income property. 

 
To register, go to the manufacturer’s website or contact your dealer. 

 

THE LIMITED WARRANTY AND LIABILITY SET FORTH HEREIN ARE IN LIEU OF ALL OTHER WARRANTIES AND LIABILITIES, 
WHETHER IN CONTRACT OR IN NEGLIGENCE, EXPRESS OR IMPLIED, IN LAW OR IN FACT, INCLUDING BUT NOT SPECIFICALLY 

LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR USE, AND IN NO EVENT SHALL 
WARRANTOR BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES. 

 

Some states and provinces do not allow limitations on how long an implied limited warranty lasts or do not allow the exclusion or limitation of 
incidental or consequential damages, so the above limitation or exclusion may not apply to you. This limited warranty gives you specific legal 

rights, and you may also have other rights which vary by jurisdiction. 
 

Parts will be provided by our factory organization through an authorized service organization in your area listed in the yellow pages. 
If you wish further help or information concerning this limited warranty, contact:  
 

Residential Systems 

6200 Troup Highway, Tyler, TX 75707 
Attention: Customer Relations 

 
TW-1044-4109 

 

* This limited warranty is for residential usage of this equipment and not applicable when this equipment is used for a commercial application. 
A commercial use is any application where the end purchaser uses the product for other than personal, family or household purposes. 

Содержание TDD-ACV

Страница 1: ... other flammable vapors and liquids or combustible materials in the vicinity of this or any other appliance WhaT To Do IF you SMeLL GaS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire departm...

Страница 2: ...espiratory skin or eye irritation PReCauTIonaRy MeaSuReS Avoid breathing fiberglass dust Use a NIOSH approved dust mist respirator Avoid contact with the skin or eyes Wear long sleeved loose fitting clothing gloves and eye protection Wash clothes separately from other clothing rinse washer thoroughly Operations such as sawing blowing tear out and spraying may generate fiber concentrations requirin...

Страница 3: ...lating materials are combustible Never stop the heating system by shutting off the main power Furnaces must have air for proper performance There must be a free flow of fresh air sufficient for efficient com bustion and safe ventilation of your furnace Never store gasoline combustible materials or other flammable liquids or vapors near your furnace Carbon monoxide fire or smoke can cause serious b...

Страница 4: ... next step 5 Turn gas cock knob counterclockwise or the toggle switch to ON marker see illustration on this page Turn the external gas cock back to the on position if you expect the furnace to light 6 Replace the furnace front access panel 7 Turn on main electrical supply and set thermostat to de sired setting Combustion blower will start and ignition device will start to heat up After approximate...

Страница 5: ...L FURNACE Manual Main Gas Shut off Valve May Be Located on the Top or Bottom Side HORIZONTAL FURNACE GAS PIPING MAY BE FROM EITHER SIDE Typical UPFLOW Furnace in horizontal configuration shown AUTOMATIC GAS VALVE WITH MANUAL SHUTOFF AUTOMATIC GAS VALVE WITH MANUAL SHUTOFF MAIN MANUAL SHUTOFF VALVE MAIN MANUAL SHUTOFF VALVE GROUND UNION JOINT GROUND UNION JOINT DRIP LEG DRIP LEG AIR FLOW AIR FLOW L...

Страница 6: ...culates and filters the air in your home dust and dirt particles build up on the filter Exces sive accumulation can block the airflow forcing the unit to work harder to maintain desired temperatures And the harder your unit has to work the more energy it uses So you pay more any time your system is running with a dirty filter CauTIon High Voltage is present within the air cleaner for operation Tur...

Страница 7: ...ates continuously No Heat Vent motor is running Unusual Noise 1 Thermostat set incorrectly 2 Blown fuse or tripped circuit breaker 3 Failed component 4 Burner does not ignite 5 Main gas line turned off 6 Blower door removed or ajar 7 Lockout 1 Dirty air filtration system 2 Blocked supply or return registers Restricted or plugged furnace Condensate drain 1 Adjust thermostat See operating instructio...

Страница 8: ...und without sagging cracks gaps etc around the base so as to provide a seal between the support and the base e There are no obvious signs of deterioration of the furnace 2 BLOWERS The blower size and speed determine the air volume delivered by the furnace The blower mo tor bearings are factory lubricated and under normal operating conditions usually do not require servicing Annual cleaning of the ...

Страница 9: ...vicinity of the furnace during normal operation 8 CONDENSATE DRAINS If you have a cooling coil in stalled with your furnace condensate drains should be checked and cleaned periodically to assure that conden sate can drain freely from coil to drain If condensate cannot drain freely water damage could occur 9 AIR CIRCULATION To ensure increased comfort the blower on this unit may be operated continu...

Страница 10: ... limited warranty does not apply if the gas furnace was purchased direct i e from internet websites or auctions on an uninstalled basis Additionally this limited warranty will not apply unless the gas furnace is 1 installed by a licensed or qualified HVAC technician 2 applied and installed in accordance with the manufacturer s recommendations in its Installer s Guide and 3 in compliance with all i...

Страница 11: ...__________________________________________________________ Indoor Coil Serial Number______________________________________________________________________________ Indoor Coil Model Number______________________________________________________________________________ Date of Installation_____________________________________________________________________________________ Dealer______________________...

Страница 12: ...ct and product data improvement it reserves the right to change design and specifications without notice Trane 6200 Troup Highway Tyler TX 75707 For more information contact your local dealer distributor File name 32 5052 06 Supersedes 32 5052 05 Date 10 09 ...

Отзывы: