background image

32-5052-06 

 

5

User’s Information

noTe The LoCaTIon oF The ManuaL MaIn GaS ShuToFF vaLve FoR youR FuRnaCe. 

Have your installer or servicer show you the location if you have any questions.

uPFLoW FuRnaCe Manual Main Gas Shut-off valve 

May be Located on the Left or Right Side

hoRIZonTaL FuRnaCe Manual Main Gas Shut-off 

valve May be Located on the Top or bottom Side

hoRIZonTaL FuRnaCe GaS PIPInG May be FRoM eITheR SIDe

(Typical uPFLoW Furnace in horizontal configuration shown)

auToMaTIC GaS vaLve
WITh ManuaL ShuToFF

auToMaTIC GaS vaLve
WITh ManuaL ShuToFF

MaIn ManuaL
ShuToFF vaLve

MaIn ManuaL
ShuToFF vaLve

GRounD unIon 

joInT

GRounD unIon 

joInT

DRIP LeG

DRIP LeG

aIR FLoW

aIR FLoW

LeFT SIDe PIPInG (STanDaRD)

ToP vIeW oF RIGhT SIDe PIPInG

RIGhT SIDe PIPInG (oPTIonaL)

Содержание TDD-ACV

Страница 1: ... other flammable vapors and liquids or combustible materials in the vicinity of this or any other appliance WhaT To Do IF you SMeLL GaS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire departm...

Страница 2: ...espiratory skin or eye irritation PReCauTIonaRy MeaSuReS Avoid breathing fiberglass dust Use a NIOSH approved dust mist respirator Avoid contact with the skin or eyes Wear long sleeved loose fitting clothing gloves and eye protection Wash clothes separately from other clothing rinse washer thoroughly Operations such as sawing blowing tear out and spraying may generate fiber concentrations requirin...

Страница 3: ...lating materials are combustible Never stop the heating system by shutting off the main power Furnaces must have air for proper performance There must be a free flow of fresh air sufficient for efficient com bustion and safe ventilation of your furnace Never store gasoline combustible materials or other flammable liquids or vapors near your furnace Carbon monoxide fire or smoke can cause serious b...

Страница 4: ... next step 5 Turn gas cock knob counterclockwise or the toggle switch to ON marker see illustration on this page Turn the external gas cock back to the on position if you expect the furnace to light 6 Replace the furnace front access panel 7 Turn on main electrical supply and set thermostat to de sired setting Combustion blower will start and ignition device will start to heat up After approximate...

Страница 5: ...L FURNACE Manual Main Gas Shut off Valve May Be Located on the Top or Bottom Side HORIZONTAL FURNACE GAS PIPING MAY BE FROM EITHER SIDE Typical UPFLOW Furnace in horizontal configuration shown AUTOMATIC GAS VALVE WITH MANUAL SHUTOFF AUTOMATIC GAS VALVE WITH MANUAL SHUTOFF MAIN MANUAL SHUTOFF VALVE MAIN MANUAL SHUTOFF VALVE GROUND UNION JOINT GROUND UNION JOINT DRIP LEG DRIP LEG AIR FLOW AIR FLOW L...

Страница 6: ...culates and filters the air in your home dust and dirt particles build up on the filter Exces sive accumulation can block the airflow forcing the unit to work harder to maintain desired temperatures And the harder your unit has to work the more energy it uses So you pay more any time your system is running with a dirty filter CauTIon High Voltage is present within the air cleaner for operation Tur...

Страница 7: ...ates continuously No Heat Vent motor is running Unusual Noise 1 Thermostat set incorrectly 2 Blown fuse or tripped circuit breaker 3 Failed component 4 Burner does not ignite 5 Main gas line turned off 6 Blower door removed or ajar 7 Lockout 1 Dirty air filtration system 2 Blocked supply or return registers Restricted or plugged furnace Condensate drain 1 Adjust thermostat See operating instructio...

Страница 8: ...und without sagging cracks gaps etc around the base so as to provide a seal between the support and the base e There are no obvious signs of deterioration of the furnace 2 BLOWERS The blower size and speed determine the air volume delivered by the furnace The blower mo tor bearings are factory lubricated and under normal operating conditions usually do not require servicing Annual cleaning of the ...

Страница 9: ...vicinity of the furnace during normal operation 8 CONDENSATE DRAINS If you have a cooling coil in stalled with your furnace condensate drains should be checked and cleaned periodically to assure that conden sate can drain freely from coil to drain If condensate cannot drain freely water damage could occur 9 AIR CIRCULATION To ensure increased comfort the blower on this unit may be operated continu...

Страница 10: ... limited warranty does not apply if the gas furnace was purchased direct i e from internet websites or auctions on an uninstalled basis Additionally this limited warranty will not apply unless the gas furnace is 1 installed by a licensed or qualified HVAC technician 2 applied and installed in accordance with the manufacturer s recommendations in its Installer s Guide and 3 in compliance with all i...

Страница 11: ...__________________________________________________________ Indoor Coil Serial Number______________________________________________________________________________ Indoor Coil Model Number______________________________________________________________________________ Date of Installation_____________________________________________________________________________________ Dealer______________________...

Страница 12: ...ct and product data improvement it reserves the right to change design and specifications without notice Trane 6200 Troup Highway Tyler TX 75707 For more information contact your local dealer distributor File name 32 5052 06 Supersedes 32 5052 05 Date 10 09 ...

Отзывы: