SS-SVX09A-EN
5
General Information
Model Number Description
All Trane products are identified by a multiple-character model number that precisely identifies a
particular type of unit. An explanation of the alphanumeric identification code is provided below.
Its use will enable the owner/operator, installing contractors, and service engineers to define the
operation, specific components, and other options for any specific unit. When ordering
replacement parts or requesting service, be sure to refer to the specific model number, serial
number, and DL number (if applicable) stamped on the unit nameplate.
Unit Nameplate
One Mylar unit nameplate is located on the outside upper right corner of the control panel door.
It includes the unit model number, serial number, electrical characteristics, weight, refrigerant
charge, as well as other pertinent unit data. A small metal nameplate with the Model Number, Serial
Number, and Unit Weight is located just above the Mylar nameplate, and a third nameplate is
located on the inside of the control panel door.
When ordering replacement parts or requesting service, be sure to refer to the specific model
number, serial number, and DL number (if applicable) stamped on the unit nameplate.
Compressor Nameplate
The nameplate for the “Scroll” compressors are located on the compressor lower housing.
Sample Model No.: RAUC - C60 E B L 1 3 A, F, G, 1, etc
Digit No.: 1 2 3 4 5,6,7 8 9 10 11 12 13+
Digit 1 - Unit Type
R = Remote Condensing Unit
Digit 2 - Condenser
A = Air Cooled
Digit 3 - Air Flow
U = Up Flow
Digit 4 - Development Sequence
C = Third
Digits 5, 6, 7 - Nominal Capacity
C20 = 20 Tons
C25 = 25 Tons
C30 = 30 Tons
C40 = 40 Tons
C50 = 50 Tons
C60 = 60 Tons
Digit 8 - Power Supply
E = 200/60/3 XL
F = 230/60/3 XL
4 = 460/60/3 XL
5 = 575/60/3 XL
9 = 380/50/3 XL
D = 415/50/3 XL
Digit 9 - System Control
B = No System Control
C = Constant Volume Control
E = Supply Air VAV Control
P = EVP Control
Digit 10 - Design Sequence
V = Disconnect Redesign
Digit 11 - Ambient Control
0 = Standard
1 = Low Ambient 0
o
F
Digit 12 - Agency Approval
0 = None
3 = UL / CSA
Digit 13 - Miscellaneous Options
A = Unit Mounted Disconnect Switch
B = Hot Gas Bypass Valves *
D = Suction Service Valves
F = Pressures Gauges & Gauge Piping *
G = Return Air Sensor *
H = Condenser Coils with Copper Fins
T = Flow Switch (EVP Only) *
1 = Spring Isolators *
2 = Neoprene Isolators *
9 = Packed Stock
* Field Installed Options
Содержание RAUC-C20
Страница 10: ...10 SS SVX09A EN Installation Figure 3 RAUC C20 Unit Dimensional Data Recommended Clearances...
Страница 11: ...SS SVX09A EN 11 Installation Figure 4 RAUC C25 Unit Dimensional Data Recommended Clearances...
Страница 12: ...12 SS SVX09A EN Installation Figure 5 RAUC C30 Unit Dimensional Data Recommended Clearances...
Страница 13: ...SS SVX09A EN 13 Installation Figure 6 RAUC C40 Unit Dimensional Data Recommended Clearances...
Страница 14: ...14 SS SVX09A EN Installation Figure 7 RAUC C50 Unit Dimensional Data Recommended Clearances...
Страница 15: ...SS SVX09A EN 15 Installation Figure 8 RAUC C60 Unit Dimensional Data Recommended Clearances...
Страница 55: ...SS SVX09A EN 55 Installation Field Connection Diagram Notes for all System Control Options...
Страница 67: ...SS SVX09A EN 67 Installation Figure 33 6RT1 Discharge Air Sensor Assembly...
Страница 96: ...96 SS SVX09A EN System Start Up Figure 47 20 Ton Pressure Curve...
Страница 97: ...SS SVX09A EN 97 System Start Up Figure 48 25 Ton Pressure Curve...
Страница 98: ...98 SS SVX09A EN System Start Up Figure 49 30Ton Pressure Curve...
Страница 99: ...SS SVX09A EN 99 System Start Up Figure 50 40 Ton Pressure Curve per Circuit...
Страница 100: ...100 SS SVX09A EN System Start Up Figure 51 50 Ton Pressure Curve per Circuit...
Страница 101: ...SS SVX09A EN 101 System Start Up Figure 52 60 Ton Pressure Curve per Circuit...