LPC-SVX01C-EN
25
DX Coil Connections
intertwined coils unit sizes 8 – 30
right hand
left hand
NOTE: DX COIL CONNECTIONS ARE SWEAT STYLE
Intertwined circuit DX coil connections, unit sizes 8 – 30, in.
unit size
A
B
C
D
E
F
G
H
J
J
1
J
2
J
3
K
K
1
K
2
K
3
L
M
N
P
four-row coil,
3
/
16
” distributor
8
2
3
/
8
6
3
/
16
18
3
/
16
14
1
/
8
3
3
/
16
4
11
/
16
5
5
/
16
7
5
/
16
1
3
/
8
--
1
3
/
8
--
5
/
8
--
5
/
8
--
--
--
--
-
10
2
3
/
8
4
7
/
8
20
1
/
8
22
5
/
8
3
3
/
16
4
11
/
16
5
5
/
16
7
5
/
16
1
3
/
8
--
1
3
/
8
--
7
/
8
--
7
/
8
--
--
--
--
--
12,14
2
3
/
8
4
7
/
8
22
13
/
16
19
11
/
16
3
3
/
16
4
11
/
16
5
5
/
16
7
5
/
16
1
3
/
8
--
1
3
/
8
--
7
/
8
--
7
/
8
--
--
--
--
--
17, 21
2
3
/
8
4
7
/
8
17
1
/
2
14
7
/
8
3
3
/
16
4
11
/
16
5
5
/
16
7
5
/
16
1
3
/
8
1
3
/
8
1
3
/
8
1
3
/
8
5
/
8
5
/
8
7
/
8
5
/
8
24
7
/
8
27
3
/
8
36
1
/
8
38
5
/
8
25
2
3
/
8
4
7
/
8
17
1
/
2
20
3
3
/
16
4
11
/
16
5
5
/
16
7
5
/
16
7
/
8
1
3
/
8
1
3
/
8
1
3
/
8
7
/
8
7
/
8
7
/
8
7
/
8
27
3
/
8
29
7
/
8
42
1
/
2
45
30
2
1
/
2
3
13
/
16
18
7
/
8
20
1
/
8
3
1
/
8
4
7
/
8
6
3
/
16
8
3
/
16
1
5
/
8
1
5
/
8
1
5
/
8
1
5
/
8
7
/
8
7
/
8
7
/
8
7
/
8
27
1
/
2
28
13
/
16
43
7
/
8
45
1
/
8
six-row coil,
1
/
4
” distributor
8
2
3
/
8
6
3
/
16
18
5
/
8
14
7
/
8
1
2
5
/
8
3
3
/
16
5
3
/
16
1
3
/
8
--
1
3
/
8
--
7
/
8
--
7
/
8
--
--
--
--
--
10
2
3
/
8
4
7
/
8
20
1
/
8
22
5
/
8
1
2
5
/
8
3
3
/
16
5
3
/
16
1
3
/
8
--
1
3
/
8
--
7
/
8
--
7
/
8
--
--
--
--
--
12,14
2
3
/
8
4
7
/
8
23
3
/
16
19
13
/
16
1
2
5
/
8
3
3
/
16
5
3
/
16
1
3
/
8
--
1
3
/
8
--
7
/
8
--
1
1
/
8
--
--
--
--
--
17, 21
2
3
/
8
4
7
/
8
17
1
/
2
15
5
/
16
1
2
5
/
8
3
3
/
16
5
3
/
16
1
3
/
8
1
3
/
8
1
3
/
8
1
3
/
8
7
/
8
7
/
8
7
/
8
7
/
8
24
7
/
8
27
3
/
8
36
1
/
2
39
25
2
3
/
8
4
7
/
8
17
1
/
2
20
1
2
5
/
8
3
3
/
16
5
3
/
16
1
3
/
8
1
3
/
8
1
3
/
8
1
3
/
8
7
/
8
7
/
8
7
/
8
7
/
8
27
3
/
8
29
7
/
8
42
1
/
2
45
30
2
1
/
2
3
13
/
16
19
11
/
16
20
7
/
8
1
2
5
/
8
6
3
/
16
8
3
/
16
1
5
/
8
1
5
/
8
1
5
/
8
1
5
/
8
1
3
/
8
1
3
/
8
1
3
/
8
1
3
/
8
27
1
/
2
28
13
/
16
44
11
/
16
45
7
/
8
Note: DX intertwined coils, on unit sizes 8 – 14 have two distributors. Unit sizes 17 – 30 have four distributors.
Installation
dimensions
& weights
AIR FLOW
AIR FLOW
Содержание LPC
Страница 50: ...50 LPC SVX01C EN Operation general information Figure O GI 9 Tracer AH540 termination board ...
Страница 89: ...LPC SVX01C EN 89 Operation sequence of operation Table O SO 19 Comm LED yellow Table O SO 20 Required inputs ...
Страница 91: ...LPC SVX01C EN 91 Maintenance diagnostics Table M D 2 Tracer AH540 541 diagnostics ...
Страница 92: ...92 LPC SVX01C EN Maintenance diagnostics Table M D 2 continued Tracer AH540 541 diagnostics ...
Страница 94: ...94 LPC SVX01C EN Maintenance troubleshooting Table M T 2 Valves stay open ...
Страница 95: ...LPC SVX01C EN 95 Maintenance troubleshooting Table M T 3 Valves stay closed ...
Страница 96: ...96 LPC SVX01C EN Maintenance troubleshooting Table M T 4 Outdoor air damper stays open ...
Страница 97: ...LPC SVX01C EN 97 Maintenance troubleshooting Table M T 5 Outdoor air damper stays closed ...
Страница 98: ...98 LPC SVX01C EN Maintenance troubleshooting Table M T 6 DX cooling binary outputs do not energize ...
Страница 99: ...LPC SVX01C EN 99 Maintenance troubleshooting Table M T 7 Electric heat binary outputs do not energize ...
Страница 104: ...104 LPC SVX01C EN Maintenance appendix Figure M A 1 Flowchart EnteringWaterTemperature Sampling Function ...
Страница 107: ...LPC SVX01C EN 107 Maintenance appendix Table M A 6 Hard wired CO2 sensor values ...
Страница 109: ......