DX Coil Connections
single circuit coils for unit sizes 3 –10 and horizontal face split coils for unit sizes 12 – 25
right hand
left hand
NOTE: DX COIL CONNECTIONS ARE SWEAT STYLE
Single circuit DX coil connections, unit sizes 3 - 10, in.
unit size
A
B
C
D (LH) D (RH) G
H
J
K
four-row coil,
3
/
16
” distributor
3
2
3
/
8
10
5
/
16
4
5
1
/
8
7
3
/
16
1
3
/
8
5
/
8
3
1
/
8
6
1
/
8
6
2
3
/
8
17
11
/
16
4
5
1
/
8
7
3
/
16
1
3
/
8
7
/
8
3
1
/
8
6
1
/
8
8
2
3
/
8
18
13
/
16
4
5
1
/
8
7
3
/
16
1
3
/
8
7
/
8
3
5
/
8
6
1
/
8
10
2
1
/
2
18
3
/
16
4
5
1
/
8
7
3
/
16
1
5
/
8
7
/
8
3
5
/
8
6
1
/
8
six-row coil,
1
/
4
” distributor
3
2
3
/
8
11
1
13
/
16
2
7
/
8
5
1
3
/
8
7
/
8
3
1
/
8
6
1
/
8
6
2
3
/
8
17
11
/
16
1
13
/
16
2
7
/
8
5
1
3
/
8
7
/
8
3
1
/
8
6
1
/
8
8
2
3
/
8
19
5
/
16
1
13
/
16
2
7
/
8
5
1
3
/
8
1
1
/
8
3
5
/
8
6
1
/
8
10
2
1
/
2
19
1
13
/
16
2
7
/
8
5
1
5
/
8
1
3
/
8
3
5
/
8
6
1
/
8
Note: Single circuit DX coils on unit sizes 3 – 10 have one distributor.
Horizontal face split circuit DX coil connections, unit sizes 8 – 25, in.
unit
size A B C D (LH) D (RH) E F G G
1
H H
1
J K
four-row coil,
3
/
16
” distributor
8
2
3
/
8
8
1
/
8
4
5
1
/
8
7
3
/
16
17
3
/
8
22
13
/
16
1
3
/
8
1
3
/
8
5
/
8
5
/
8
3
5
/
8
6
1
/
8
10
2
3
/
8
8
1
/
8
4
5
1
/
8
7
3
/
16
14
7
/
8
22
3
/
8
1
3
/
8
1
3
/
8
7
/
8
7
/
8
3
5
/
8
6
1
/
8
12, 14
1
7
/
8
12
5
/
8
4
5
1
/
8
7
3
/
16
19
7
/
8
31
1
/
8
1
3
/
8
1
3
/
8
7
/
8
7
/
8
3
5
/
8
6
1
/
8
17, 21
1
7
/
8
17
5
/
8
4
5
1
/
8
7
3
/
16
25
41
3
/
8
1
5
/
8
1
5
/
8
7
/
8
7
/
8
3
5
/
8
6
1
/
8
25
1
7
/
8
18
5
/
16
4
5
5
/
16
7
3
/
16
27
1
/
2
43
5
/
16
1
5
/
8
1
5
/
8
7
/
8
7
/
8
4
5
/
8
8
1
/
8
six-row coil,
1
/
4
” distributor
8
2
3
/
8
8
13
/
16
1
13
/
16
2
7
/
8
5
17
3
/
8
22
3
/
8
1
3
/
8
1
3
/
8
7
/
8
7
/
8
3
5
/
8
6
1
/
8
10
2
3
/
8
13
/
16
1
13
/
16
2
7
/
8
5
14
7
/
8
22
3
/
8
1
3
/
8
1
5
/
8
7
/
8
7
/
8
3
5
/
8
6
1
/
8
12, 14
2
3
/
8
13
1
13
/
16
2
7
/
8
5
19
7
/
8
31
3
/
8
1
3
/
8
1
3
/
8
1
1
/
8
7
/
8
3
5
/
8
6
1
/
8
17, 21
2
3
/
8
18
3
/
16
1
13
/
16
2
7
/
8
5
25
42
1
5
/
8
1
5
/
8
1
1
/
8
1
1
/
8
3
5
/
8
6
1
/
8
Installation
dimensions
& weights
AIR FLOW
AIR FLOW
Содержание LPC
Страница 50: ...50 LPC SVX01C EN Operation general information Figure O GI 9 Tracer AH540 termination board ...
Страница 89: ...LPC SVX01C EN 89 Operation sequence of operation Table O SO 19 Comm LED yellow Table O SO 20 Required inputs ...
Страница 91: ...LPC SVX01C EN 91 Maintenance diagnostics Table M D 2 Tracer AH540 541 diagnostics ...
Страница 92: ...92 LPC SVX01C EN Maintenance diagnostics Table M D 2 continued Tracer AH540 541 diagnostics ...
Страница 94: ...94 LPC SVX01C EN Maintenance troubleshooting Table M T 2 Valves stay open ...
Страница 95: ...LPC SVX01C EN 95 Maintenance troubleshooting Table M T 3 Valves stay closed ...
Страница 96: ...96 LPC SVX01C EN Maintenance troubleshooting Table M T 4 Outdoor air damper stays open ...
Страница 97: ...LPC SVX01C EN 97 Maintenance troubleshooting Table M T 5 Outdoor air damper stays closed ...
Страница 98: ...98 LPC SVX01C EN Maintenance troubleshooting Table M T 6 DX cooling binary outputs do not energize ...
Страница 99: ...LPC SVX01C EN 99 Maintenance troubleshooting Table M T 7 Electric heat binary outputs do not energize ...
Страница 104: ...104 LPC SVX01C EN Maintenance appendix Figure M A 1 Flowchart EnteringWaterTemperature Sampling Function ...
Страница 107: ...LPC SVX01C EN 107 Maintenance appendix Table M A 6 Hard wired CO2 sensor values ...
Страница 109: ......