RT-SVX063E-EN
57
W
WA
AR
RN
NIIN
NG
G
R
Ro
otta
attiin
ng
g C
Co
om
mp
po
on
ne
en
nttss!!
F
Fa
aiillu
urre
e tto
o d
diisscco
on
nn
ne
ecctt p
po
ow
we
err b
be
effo
orre
e sse
errv
viicciin
ng
g cco
ou
ulld
d
rre
essu
ulltt iin
n rro
otta
attiin
ng
g cco
om
mp
po
on
ne
en
nttss ccu
uttttiin
ng
g a
an
nd
d sslla
assh
hiin
ng
g
tte
ecch
hn
niicciia
an
n w
wh
hiicch
h cco
ou
ulld
d rre
essu
ulltt iin
n d
de
ea
atth
h o
orr sse
erriio
ou
uss
iin
njju
urry
y..
D
Du
urriin
ng
g iin
nsstta
alllla
attiio
on
n,, tte
essttiin
ng
g,, sse
errv
viicciin
ng
g a
an
nd
d
ttrro
ou
ub
blle
essh
ho
oo
ottiin
ng
g o
off tth
hiiss p
prro
od
du
ucctt iitt m
ma
ay
y b
be
e
n
ne
ecce
essssa
arry
y tto
o w
wo
orrkk w
wiitth
h lliiv
ve
e a
an
nd
d e
ex
xp
po
osse
ed
d rro
otta
attiin
ng
g
cco
om
mp
po
on
ne
en
nttss.. H
Ha
av
ve
e a
a q
qu
ua
alliiffiie
ed
d o
orr lliicce
en
nsse
ed
d sse
errv
viicce
e
iin
nd
diiv
viid
du
ua
all w
wh
ho
o h
ha
ass b
be
ee
en
n p
prro
op
pe
errlly
y ttrra
aiin
ne
ed
d iin
n
h
ha
an
nd
dlliin
ng
g e
ex
xp
po
osse
ed
d rro
otta
attiin
ng
g cco
om
mp
po
on
ne
en
nttss,, p
pe
errffo
orrm
m
tth
he
esse
e tta
asskkss..
3. Press the Stop button on the user interface. To
setup and troubleshoot supply fan operation,
navigate to Supply Fan Manual Override by
following the steps provided below.
N
No
otte
e:: The unit’s design supply airflow is
established when the supply fan is operating
at 100% speed command. If the design
supply airflow rating of the unit needs to be
modified, the new maximum design speed
must be set at the supply fan’s variable
frequency drive (VFD) key pad. The user
should identify the maximum speed for the
supply fan wheels and ensure those speeds
are not exceeded when making entries at the
VFD key pads.
a. Press Stop and then touch Settings.
b. Touch Manual Control Settings in the Settings
screen.
c. Touch Supply Fan Manual Override in the
Manual Control Settings screen.
d.
Touch Manual, then touch Change value to: to
adjust the speed setting, press Enter, then press
Apply.
e. When done testing, touch Clear All Manual
Overrides or select the individual override and
press Auto.
4. The above procedure can be followed for testing
and setup of relief fans and condenser fans.
N
No
otte
e:: Changes to the unit’s design relief airflow
rating is modified at the user interface by
adjusting the Relief Fan Maximum Speed
Setpoint located under the Service Settings
menu.
Check all fans for proper rotation. Supply Fan
rotation is indicated by an arrow located on the fan
housing (clockwise from motor side of fan). Relief
Fan rotation is counter-clockwise when viewed
from the motor side of the fan assembly.
Condenser Fan rotation is clockwise when viewed
from the top.
S
Stta
arrttu
up
p tth
he
e U
Un
niitt