64
M
odule
I/O S
u
m
m
a
ry
UNI
T
M
O
DUL
E
ANAL
O
G
I
N
P
U
T
S
ANAL
O
G
O
U
T
P
UT
S
B
INARY
I
N
P
U
T
S
BI
NARY
O
U
T
P
UT
S
G
ener
ic
B
u
ilding
F
o
ur
input
s
, whic
h c
a
n
F
our
out
p
ut
s
, whic
h c
a
n
• Dem
a
nd Lim
it
O
ne out
put
, whic
h
Au
to
ma
ti
o
n
Syst
e
m
0
-
be as
s
igned:
be as
s
ig
ned:
c
an be as
s
ig
ned:
10V
D
C (
G
B
A
S
0-
10V
)
• Leav
ing S
o
lut
ion S
e
tpoint
• Leav
ing S
o
ln T
e
m
p
• Com
p
re
s
s
o
rs
r
unning
M
odule
• I
c
e B
u
ild T
e
rm
inat
e S
e
tpoint
• E
n
te
ri
ng S
o
ln T
e
m
p
• Running at
m
a
x
im
u
m
• Hot
S
tar
t Load Lim
it
S
e
tpoint
• S
a
t.
Cond T
e
m
p
Ck
t1
c
a
pac
it
y
• M
a
x
im
u
m
Capac
it
y
Lev
el
• S
a
t.
Cond T
e
m
p
Ck
t2
• S
e
lec
ted diagnos
ti
c
s
S
e
tpoint
• E
v
ap T
e
m
p
Ck
t1
m
e
s
s
ages
• E
v
a
p
Te
m
p
C
k
t2
• IC
S
D
e
fi
n
e
d
Te
m
p
• L
iq
u
id
P
re
s
s
u
re
C
k
t1
• Su
ct
io
n
Pre
s
su
re
C
k
t1
• L
iq
u
id
P
re
s
s
u
re
C
k
t2
• Su
ct
io
n
Pre
s
su
re
C
k
t2
• A
c
ti
v
e
Cooling Capac
it
y
• O
u
tdoor
A
ir
T
e
m
p
• S
a
tu
ra
ted Liquid T
e
m
p
Ck
t1
• S
a
tu
ra
ted Liquid T
e
m
p
Ck
t2
Hum
a
n I
n
te
rf
ac
e (
H
I)
• None
• None
• None
• None
M
odule
In
te
rp
ro
ce
sso
r
• N
o
n
e
• N
o
n
e
• N
o
n
e
• N
o
n
e
Com
m
unic
a
ti
ons
B
ridge (
IP
C
B
) M
odule
M
u
lt
iple Com
p
re
s
s
or
• E
v
ap/
S
u
c
tion T
e
m
p
er
at
ur
e
• Condens
er
F
a
n S
peed
• Com
p
re
s
s
o
r P
rov
ing (
C
k
t #1)
• Com
p
re
s
s
o
r Relay
K
1
1
M
odule (
M
CM
)
(C
kt
#
1
)
(L
ow A
m
bient
Ck
t #1)
• Com
p
re
s
s
o
r P
rov
ing (
C
k
t #2)
• Com
p
re
s
s
o
r Relay
K
1
2
• E
v
ap/
S
u
c
tion T
e
m
p
er
at
ur
e
• Condens
er
F
a
n S
peed
• Low P
res
s
u
re
Cut
out
(C
k
t #1)
• Com
p
re
s
s
o
r Relay
K
3
(C
kt
#
2
)
(L
ow A
m
bient
Ck
t #2)
• Low P
res
s
u
re
Cut
out
(
C
k
t #2)
• Com
p
re
s
s
o
r Relay
K
4
• S
a
tu
ra
ted Condens
er
• High P
res
s
u
re
Cont
ro
l (
C
k
t #1)
• Condens
er
F
an 1A
T
e
m
per
at
ur
e S
ens
or
(
C
k
t #1)
• High P
res
s
u
re
Cont
ro
l (
C
k
t #2)
• Condens
er
F
an 1B
• S
a
tu
ra
ted Condens
er
• Condens
er
F
an 1C
T
e
m
per
at
ur
e S
ens
or
(
C
k
t #2)
• Condens
er
F
an 2A
• S
a
tu
ra
ted Liquid T
e
m
p
(
C
k
t #1)
• Condens
er
F
an 2B
• S
a
tu
ra
ted Liquid T
e
m
p
(
C
k
t #2)
• Condens
er
F
an 2C
• Heat
er
T
ape
S
ingle Com
p
re
s
s
or
• E
v
ap/
S
u
c
tion T
e
m
p
er
at
ur
e
• Condens
er
F
a
n S
peed
• Com
p
re
s
s
o
r P
rov
ing
• Com
p
re
s
s
o
r Relay
K
1
1
M
odule (
S
CM
)
• S
a
tu
ra
ted Condens
er
(L
ow A
m
bient
)
• Low P
res
s
u
re
Cut
out
• Com
p
re
s
s
o
r Relay
K
1
2
T
e
m
p
er
at
ur
e
• High P
res
s
u
re
Cont
ro
l
• Condens
er
F
an A
• S
a
tu
ra
ted Liquid T
e
m
per
at
ur
e
• Condens
er
F
an B
Содержание IntelliPak CGAF Series
Страница 68: ...68...